{"id":"https://openalex.org/W2492475222","doi":null,"title":"Evaluation of cable polymer aging through Indenter testing of in-plant and laboratory-aged specimens. Final report","display_name":"Evaluation of cable polymer aging through Indenter testing of in-plant and laboratory-aged specimens. Final report","alternate_titles":[],"publication_year":1996,"publication_date":"1996-01-01","ids":{"openalex":"https://openalex.org/W2492475222","mag":"2492475222"},"language":"en","primary_location":{"id":"mag:2492475222","doi":null,"is_oa":false,"landing_page_url":"http://www.osti.gov/scitech/biblio/383661-evaluation-cable-polymer-aging-through-indenter-testing-plant-laboratory-aged-specimens-final-report","pdf_url":null,"source":{"id":"https://openalex.org/S4306402487","display_name":"OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I139351228","host_organization_name":"Office of Scientific and Technical Information","host_organization_lineage":["https://openalex.org/I139351228"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":null},"parent_works":[],"lineage":["https://openalex.org/W2492475222"],"child_works_count":0,"type":"report","is_traditional":false,"indexed_in":[],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5013586056","display_name":"Gary J. Toman","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"G.J. Toman","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"last","author":{"id":"https://openalex.org/A5044654628","display_name":"R.F. Gazdzinski","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"R.F. Gazdzinski","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]}],"institutions":[],"countries_distinct_count":0,"institutions_distinct_count":0,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":null,"has_fulltext":false,"cited_by_count":8,"citation_normalized_percentile":null,"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":null,"last_page":null},"is_retracted":false,"is_pulled":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10511","display_name":"High voltage insulation and dielectric phenomena","score":0.9634000062942505,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10511","display_name":"High voltage insulation and dielectric phenomena","score":0.9634000062942505,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11343","display_name":"Power Transformer Diagnostics and Insulation","score":0.00800000037997961,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10780","display_name":"Reliability and Maintenance Optimization","score":0.007600000128149986,"subfield":{"id":"https://openalex.org/subfields/2213","display_name":"Safety, Risk, Reliability and Quality"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/cable-insulation","display_name":"cable insulation","score":0.7360000014305115},{"id":"https://openalex.org/keywords/cable-jacketing","display_name":"cable jacketing","score":0.9729999899864197},{"id":"https://openalex.org/keywords/artificial-aging","display_name":"artificial aging","score":0.8970000147819519},{"id":"https://openalex.org/keywords/modulus-measurement","display_name":"modulus measurement","score":0.6330000162124634}],"concepts":[{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.5921498537063599},{"id":"https://openalex.org/C18140158","wikidata":"https://www.wikidata.org/wiki/Q7079901","display_name":"Ogden","level":2,"score":0.4814700186252594},{"id":"https://openalex.org/C77595967","wikidata":"https://www.wikidata.org/wiki/Q3151013","display_name":"Forensic engineering","level":1,"score":0.45415252447128296},{"id":"https://openalex.org/C66938386","wikidata":"https://www.wikidata.org/wiki/Q633538","display_name":"Structural engineering","level":1,"score":0.39183494448661804},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.3588639497756958},{"id":"https://openalex.org/C192562407","wikidata":"https://www.wikidata.org/wiki/Q228736","display_name":"Materials science","level":0,"score":0.1764240860939026},{"id":"https://openalex.org/C159985019","wikidata":"https://www.wikidata.org/wiki/Q181790","display_name":"Composite material","level":1,"score":0.14582377672195435}],"mesh":[],"locations_count":1,"locations":[{"id":"mag:2492475222","doi":null,"is_oa":false,"landing_page_url":"http://www.osti.gov/scitech/biblio/383661-evaluation-cable-polymer-aging-through-indenter-testing-plant-laboratory-aged-specimens-final-report","pdf_url":null,"source":{"id":"https://openalex.org/S4306402487","display_name":"OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I139351228","host_organization_name":"Office of Scientific and Technical Information","host_organization_lineage":["https://openalex.org/I139351228"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":null}],"best_oa_location":null,"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/9","display_name":"Industry, innovation and infrastructure","score":0.7207000255584717}],"study_designs":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":0,"referenced_works":[],"related_works":["https://openalex.org/W1850271124","https://openalex.org/W7203652474","https://openalex.org/W1578476860","https://openalex.org/W3144588033","https://openalex.org/W2747516055","https://openalex.org/W1965547096","https://openalex.org/W4285013015","https://openalex.org/W2124220091","https://openalex.org/W2886075884","https://openalex.org/W1980420617"],"abstract_inverted_index":{"This":[0],"report":[1],"documents":[2],"the":[3,13,27,37,47,50,96,101,105],"in-plant":[4,53],"testing":[5],"and":[6,33,40,55,61,91,100],"evaluation":[7,25,45],"of":[8,12,26,29,36,42,46,49,58,69,104],"cables":[9,82],"through":[10],"use":[11],"Ogden/EPRI":[14],"Polymer":[15],"Aging":[16],"Monitor":[17],"(Indenter),":[18],"a":[19,56],"device":[20],"that":[21],"allows":[22],"nondestructive,":[23],"in-situ":[24],"aging":[28,60,98],"electrical":[30],"cable":[31,62,73,106],"insulation":[32],"jacketing.":[34],"Descriptions":[35],"Indenter":[38,76],"system":[39,51],"theory":[41],"operation,":[43],"an":[44],"effectiveness":[48],"during":[52],"trials,":[54],"discussion":[57],"artificial":[59,97],"life":[63],"projection":[64],"methodology":[65],"for":[66],"various":[67],"types":[68],"common":[70],"nuclear":[71,87],"plant":[72],"are":[74,93,107],"provided.":[75],"modulus":[77],"measurements":[78],"performed":[79],"on":[80],"in-service":[81],"at":[83],"three":[84],"Commonwealth":[85],"Edison":[86],"stations":[88],"(Dresden,":[89],"Zion,":[90],"LaSalle)":[92],"compared":[94],"to":[95],"results,":[99],"service":[102],"lives":[103],"predicted.":[108]},"cited_by_api_url":"https://api.openalex.org/works?filter=cites:W2492475222","counts_by_year":[{"year":2025,"cited_by_count":1},{"year":2017,"cited_by_count":3},{"year":2013,"cited_by_count":2}],"updated_date":"2026-11-16T12:05:36.265796","created_date":"2016-08-23T00:00:00"}
