{"id":"https://openalex.org/W2490981996","doi":"https://doi.org/10.1109/tpel.2016.2592944","title":"Digital Current Sensorless Control for Dual-Boost Half-Bridge PFC Converter With Natural Capacitor Voltage Balancing","display_name":"Digital Current Sensorless Control for Dual-Boost Half-Bridge PFC Converter With Natural Capacitor Voltage Balancing","alternate_titles":[],"publication_year":2016,"publication_date":"2016-07-19","ids":{"openalex":"https://openalex.org/W2490981996","doi":"https://doi.org/10.1109/tpel.2016.2592944","mag":"2490981996"},"language":"en","primary_location":{"id":"doi:10.1109/tpel.2016.2592944","doi":"https://doi.org/10.1109/tpel.2016.2592944","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tpel.2016.2592944","pdf_url":null,"source":{"id":"https://openalex.org/S29875816","display_name":"IEEE Transactions on Power Electronics","issn_l":"0885-8993","issn":["0885-8993","1941-0107"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["cwts-core","dongbi-a","jufo-3","norway-2","poland-200","russia-white-list-1"],"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Power Electronics","raw_type":"journal-article"},"parent_works":[],"lineage":["https://openalex.org/W2490981996"],"child_works_count":0,"pull_notice_works":[],"type":"article","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5101704525","display_name":"Hung\u2010Chi Chen","type":null,"orcid":"https://orcid.org/0000-0002-8515-7685","observed_orcids":["https://orcid.org/0000-0002-8515-7685"]},"acted_on_behalf_of":[],"institutions":[{"id":"https://openalex.org/I148366613","display_name":"National Yang Ming Chiao Tung University","ror":"https://ror.org/00se2k293","country_code":"TW","type":"education","lineage":["https://openalex.org/I148366613"]}],"countries":["TW"],"is_corresponding":false,"contributor_roles":[],"raw_author_name":"Hung-Chi Chen","raw_affiliation_strings":["Department of Electrical and Computer Engineering, National Chiao Tung University, Hsinchu, Taiwan"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Electrical and Computer Engineering, National Chiao Tung University, Hsinchu, Taiwan","institution_ids":["https://openalex.org/I148366613"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5007318122","display_name":"Che-Yu Lu","type":null,"orcid":"https://orcid.org/0000-0002-8738-5817","observed_orcids":["https://orcid.org/0000-0002-8738-5817"]},"acted_on_behalf_of":[],"institutions":[{"id":"https://openalex.org/I148366613","display_name":"National Yang Ming Chiao Tung University","ror":"https://ror.org/00se2k293","country_code":"TW","type":"education","lineage":["https://openalex.org/I148366613"]}],"countries":["TW"],"is_corresponding":false,"contributor_roles":[],"raw_author_name":"Che-Yu Lu","raw_affiliation_strings":["Institution of Electrical Control Engineering, National Chiao Tung University, Hsinchu, Taiwan"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Institution of Electrical Control Engineering, National Chiao Tung University, Hsinchu, Taiwan","institution_ids":["https://openalex.org/I148366613"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5063462483","display_name":"Guan-Ting Li","type":null,"orcid":null,"observed_orcids":[]},"acted_on_behalf_of":[],"institutions":[{"id":"https://openalex.org/I148366613","display_name":"National Yang Ming Chiao Tung University","ror":"https://ror.org/00se2k293","country_code":"TW","type":"education","lineage":["https://openalex.org/I148366613"]}],"countries":["TW"],"is_corresponding":false,"contributor_roles":[],"raw_author_name":"Guan-Ting Li","raw_affiliation_strings":["Institution of Electrical Control Engineering, National Chiao Tung University, Hsinchu, Taiwan"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Institution of Electrical Control Engineering, National Chiao Tung University, Hsinchu, Taiwan","institution_ids":["https://openalex.org/I148366613"]}]},{"author_position":"last","author":{"id":null,"display_name":"Wei-Cheng Chen","type":null,"orcid":null,"observed_orcids":[]},"acted_on_behalf_of":[],"institutions":[{"id":"https://openalex.org/I148366613","display_name":"National Yang Ming Chiao Tung University","ror":"https://ror.org/00se2k293","country_code":"TW","type":"education","lineage":["https://openalex.org/I148366613"]}],"countries":["TW"],"is_corresponding":false,"contributor_roles":[],"raw_author_name":"Wei-Cheng Chen","raw_affiliation_strings":["Institution of Electrical Control Engineering, National Chiao Tung University, Hsinchu, Taiwan"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Institution of Electrical Control Engineering, National Chiao Tung University, Hsinchu, Taiwan","institution_ids":["https://openalex.org/I148366613"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":["https://openalex.org/I148366613"],"apc_list":{"value":2645,"currency":"USD","value_usd":2645},"apc_paid":null,"fwci":1.1025,"has_fulltext":false,"cited_by_count":36,"reviewed_by_count":0,"citation_normalized_percentile":{"value":0.76263849,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":92,"max":98},"biblio":{"volume":"32","issue":"5","first_page":"4074","last_page":"4083"},"is_retracted":false,"is_pulled":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10175","display_name":"Advanced DC-DC Converters","score":0.9984999895095825,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10175","display_name":"Advanced DC-DC Converters","score":0.9984999895095825,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10228","display_name":"Multilevel Inverters and Converters","score":0.0003000000142492354,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10323","display_name":"Analog and Mixed-Signal Circuit Design","score":9.999999747378752e-05,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/current-sensorless-control","display_name":"current sensorless control","score":0.9620000123977661},{"id":"https://openalex.org/keywords/power-factor-correction","display_name":"power factor correction","score":0.8980000019073486},{"id":"https://openalex.org/keywords/capacitor-voltage-balancing","display_name":"capacitor voltage balancing","score":0.9179999828338623},{"id":"https://openalex.org/keywords/voltage-control","display_name":"voltage regulation","score":0.8429999947547913},{"id":"https://openalex.org/keywords/sinusoidal-input-current","display_name":"sinusoidal input current","score":0.9139999747276306},{"id":"https://openalex.org/keywords/sensorless-current-estimation","display_name":"sensorless current estimation","score":0.49900001287460327}],"concepts":[{"id":"https://openalex.org/C2778422915","wikidata":"https://www.wikidata.org/wiki/Q10302051","display_name":"Converters","level":3,"score":0.6640341281890869},{"id":"https://openalex.org/C78336795","wikidata":"https://www.wikidata.org/wiki/Q760134","display_name":"Boost converter","level":3,"score":0.6361752152442932},{"id":"https://openalex.org/C52192207","wikidata":"https://www.wikidata.org/wiki/Q5322","display_name":"Capacitor","level":3,"score":0.6034978628158569},{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.5390337109565735},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.5370634198188782},{"id":"https://openalex.org/C64424096","wikidata":"https://www.wikidata.org/wiki/Q750454","display_name":"Power factor","level":3,"score":0.5154091119766235},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.4452565014362335},{"id":"https://openalex.org/C123414225","wikidata":"https://www.wikidata.org/wiki/Q1422221","display_name":"Current loop","level":3,"score":0.4338723123073578},{"id":"https://openalex.org/C144534570","wikidata":"https://www.wikidata.org/wiki/Q5325","display_name":"Inductor","level":3,"score":0.43264830112457275},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.40548622608184814},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.40439099073410034},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.18391487002372742},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.16854840517044067},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/tpel.2016.2592944","doi":"https://doi.org/10.1109/tpel.2016.2592944","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tpel.2016.2592944","pdf_url":null,"source":{"id":"https://openalex.org/S29875816","display_name":"IEEE Transactions on Power Electronics","issn_l":"0885-8993","issn":["0885-8993","1941-0107"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["cwts-core","dongbi-a","jufo-3","norway-2","poland-200","russia-white-list-1"],"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Power Electronics","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[{"score":0.875,"id":"https://metadata.un.org/sdg/7","display_name":"Affordable and clean energy"},{"score":0.651199996471405,"id":"https://metadata.un.org/sdg/9","display_name":"Industry, innovation and infrastructure"}],"study_designs":[],"awards":[{"id":"https://openalex.org/G7805031709","display_name":"Position Sensorless Control for Five-Phase PMSMs","funder_award_id":"NSC102-2221-E009-048-MY3","funder_id":"https://openalex.org/F4320322795","funder_display_name":"Ministry of Science and Technology, Taiwan"}],"funders":[{"id":"https://openalex.org/F4320322795","display_name":"Ministry of Science and Technology, Taiwan","ror":"https://ror.org/02kv4zf79"}],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":29,"referenced_works":["https://openalex.org/W1518121583","https://openalex.org/W1914971061","https://openalex.org/W1964806739","https://openalex.org/W1971562831","https://openalex.org/W1997781430","https://openalex.org/W2005231486","https://openalex.org/W2007560562","https://openalex.org/W2009892009","https://openalex.org/W2022948455","https://openalex.org/W2033621134","https://openalex.org/W2035667222","https://openalex.org/W2078666293","https://openalex.org/W2083652563","https://openalex.org/W2088166149","https://openalex.org/W2089346488","https://openalex.org/W2091148628","https://openalex.org/W2098244176","https://openalex.org/W2112369798","https://openalex.org/W2113164503","https://openalex.org/W2139789473","https://openalex.org/W2141677573","https://openalex.org/W2154406341","https://openalex.org/W2154689456","https://openalex.org/W2159673503","https://openalex.org/W2163951918","https://openalex.org/W2169605411","https://openalex.org/W2171520892","https://openalex.org/W2179669256","https://openalex.org/W4231739559"],"related_works":["https://openalex.org/W1892490343","https://openalex.org/W2616061627","https://openalex.org/W2171520892","https://openalex.org/W4414646980","https://openalex.org/W2373040256","https://openalex.org/W2102470377","https://openalex.org/W2799264206","https://openalex.org/W1888951466","https://openalex.org/W1999117621","https://openalex.org/W2165499354"],"abstract_inverted_index":{"To":[0],"improve":[1],"the":[2,5,14,18,36,44,54,61,65,68,82,87,105,114,140,152],"efficiency":[3],"of":[4,21,63,67],"conventional":[6,55],"boost-type":[7],"power":[8],"factor":[9],"correction":[10],"(PFC)":[11],"converters":[12,20],"with":[13,104],"diode":[15],"bridge":[16],"circuit,":[17],"PFC":[19,45,70,89,134],"bridgeless":[22],"category":[23],"are":[24,72,148],"often":[25],"used.":[26],"Due":[27],"to":[28,52,93,119,138,150],"no":[29,33],"series-connected":[30],"switches":[31],"and":[32,59,74,97,145],"short-through":[34],"risks,":[35],"dual-boost":[37],"half-bridge":[38],"(DBHB)":[39],"circuit":[40],"is":[41,79,91,117,136],"used":[42],"as":[43],"converter":[46,71,90],"in":[47,102],"this":[48],"paper.":[49],"In":[50,112],"order":[51],"simplify":[53],"two-loop":[56],"control":[57,85,129,141,156],"scheme":[58],"reduce":[60],"number":[62],"sensors,":[64],"behaviors":[66],"DBHB":[69,88,133],"studied":[73],"its":[75],"equivalent":[76],"single-switch":[77],"model":[78],"developed.":[80],"Then,":[81],"current":[83,101,154],"sensorless":[84,155],"for":[86],"proposed":[92,115,153],"achieve":[94],"voltage":[95,107,127],"regulation":[96],"yield":[98],"sinusoidal":[99],"input":[100,106],"phase":[103],"without":[108,124],"sensing":[109],"any":[110,126],"current.":[111],"addition,":[113],"method":[116],"able":[118],"balance":[120],"capacitor":[121],"voltages":[122],"naturally":[123],"adding":[125],"balancing":[128],"loop.":[130],"An":[131],"800-W":[132],"prototype":[135],"implemented":[137],"evaluate":[139],"performance.":[142],"Both":[143],"simulation":[144],"experimental":[146],"results":[147],"provided":[149],"demonstrate":[151],"method.":[157]},"cited_by_api_url":"https://api.openalex.org/works?filter=cites:W2490981996","counts_by_year":[{"year":2026,"cited_by_count":4},{"year":2025,"cited_by_count":3},{"year":2024,"cited_by_count":5},{"year":2023,"cited_by_count":2},{"year":2022,"cited_by_count":3},{"year":2021,"cited_by_count":2},{"year":2020,"cited_by_count":7},{"year":2019,"cited_by_count":3},{"year":2018,"cited_by_count":4},{"year":2017,"cited_by_count":3}],"updated_date":"2026-11-25T09:40:18.809321","created_date":"2016-08-23T00:00:00"}
