{"id":"https://openalex.org/W24788753","doi":null,"title":"SAFETY AND RELIABILITY OF REACTOR INSTRUMENTATION WITH REDUNDANT INSTRUMENT CHANNELS","display_name":"SAFETY AND RELIABILITY OF REACTOR INSTRUMENTATION WITH REDUNDANT INSTRUMENT CHANNELS","alternate_titles":[],"publication_year":1962,"publication_date":"1962-01-01","ids":{"openalex":"https://openalex.org/W24788753","mag":"24788753"},"language":"en","primary_location":{"id":"mag:24788753","doi":null,"is_oa":false,"landing_page_url":"http://www.osti.gov/scitech/biblio/4798919-safety-reliability-reactor-instrumentation-redundant-instrument-channels","pdf_url":null,"source":{"id":"https://openalex.org/S4306402487","display_name":"OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I139351228","host_organization_name":"Office of Scientific and Technical Information","host_organization_lineage":["https://openalex.org/I139351228"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":null},"parent_works":[],"lineage":["https://openalex.org/W24788753"],"child_works_count":0,"pull_notice_works":[],"type":"report","is_traditional":false,"indexed_in":[],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":null,"display_name":"J. Rasmussen","type":null,"orcid":null,"observed_orcids":[]},"acted_on_behalf_of":[],"institutions":[],"countries":[],"is_corresponding":false,"contributor_roles":[],"raw_author_name":"J. Rasmussen","raw_affiliation_strings":["Ris\u00f8 National Laboratory"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Ris\u00f8 National Laboratory","institution_ids":[]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5071626085","display_name":"P. Timmermann","type":null,"orcid":null,"observed_orcids":[]},"acted_on_behalf_of":[],"institutions":[],"countries":[],"is_corresponding":false,"contributor_roles":[],"raw_author_name":"P. Timmermann","raw_affiliation_strings":["Ris\u00f8 National Laboratory"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Ris\u00f8 National Laboratory","institution_ids":[]}]}],"institutions":[],"countries_distinct_count":0,"institutions_distinct_count":0,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":null,"has_fulltext":true,"cited_by_count":7,"reviewed_by_count":0,"citation_normalized_percentile":null,"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":null,"last_page":null},"is_retracted":false,"is_pulled":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11357","display_name":"Risk and Safety Analysis","score":0.46880000829696655,"subfield":{"id":"https://openalex.org/subfields/2213","display_name":"Safety, Risk, Reliability and Quality"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11357","display_name":"Risk and Safety Analysis","score":0.46880000829696655,"subfield":{"id":"https://openalex.org/subfields/2213","display_name":"Safety, Risk, Reliability and Quality"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10780","display_name":"Reliability and Maintenance Optimization","score":0.4255000054836273,"subfield":{"id":"https://openalex.org/subfields/2213","display_name":"Safety, Risk, Reliability and Quality"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12560","display_name":"Nuclear Engineering Thermal-Hydraulics","score":0.03590000048279762,"subfield":{"id":"https://openalex.org/subfields/2104","display_name":"Nuclear Energy and Engineering"},"field":{"id":"https://openalex.org/fields/21","display_name":"Energy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/nuclear-reactor-instrumentation","display_name":"nuclear reactor instrumentation","score":0.9020000100135803},{"id":"https://openalex.org/keywords/reactor-shutdown","display_name":"reactor shutdown","score":0.8330000042915344},{"id":"https://openalex.org/keywords/instrument-reliability","display_name":"instrument reliability","score":0.5299999713897705},{"id":"https://openalex.org/keywords/nuclear-reactor-safety","display_name":"nuclear reactor safety","score":0.8489999771118164}],"concepts":[{"id":"https://openalex.org/C43214815","wikidata":"https://www.wikidata.org/wiki/Q7310987","display_name":"Reliability (semiconductor)","level":3,"score":0.750110924243927},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.7266855835914612},{"id":"https://openalex.org/C118530786","wikidata":"https://www.wikidata.org/wiki/Q1134732","display_name":"Instrumentation (computer programming)","level":2,"score":0.643764853477478},{"id":"https://openalex.org/C62646347","wikidata":"https://www.wikidata.org/wiki/Q2041172","display_name":"Measuring instrument","level":2,"score":0.48544222116470337},{"id":"https://openalex.org/C163164238","wikidata":"https://www.wikidata.org/wiki/Q2737027","display_name":"Failure rate","level":2,"score":0.43400606513023376},{"id":"https://openalex.org/C116915560","wikidata":"https://www.wikidata.org/wiki/Q83504","display_name":"Nuclear engineering","level":1,"score":0.3597748279571533},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.3496706485748291},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.3242318630218506},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.06972408294677734},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.0},{"id":"https://openalex.org/C97355855","wikidata":"https://www.wikidata.org/wiki/Q11473","display_name":"Thermodynamics","level":1,"score":0.0},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"mag:24788753","doi":null,"is_oa":false,"landing_page_url":"http://www.osti.gov/scitech/biblio/4798919-safety-reliability-reactor-instrumentation-redundant-instrument-channels","pdf_url":null,"source":{"id":"https://openalex.org/S4306402487","display_name":"OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I139351228","host_organization_name":"Office of Scientific and Technical Information","host_organization_lineage":["https://openalex.org/I139351228"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":null}],"best_oa_location":null,"sustainable_development_goals":[],"study_designs":[],"awards":[{"id":"https://openalex.org/G236477335","display_name":null,"funder_award_id":"NNF14OC0011645","funder_id":"https://openalex.org/F4320325957","funder_display_name":"Novo Nordisk Fonden"}],"funders":[{"id":"https://openalex.org/F4320325957","display_name":"Novo Nordisk Fonden","ror":"https://ror.org/04txyc737"}],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":0,"referenced_works":[],"related_works":["https://openalex.org/W245961781","https://openalex.org/W2274450385","https://openalex.org/W118054983","https://openalex.org/W142673059","https://openalex.org/W3015319778","https://openalex.org/W2015852528","https://openalex.org/W34720481","https://openalex.org/W2300348847","https://openalex.org/W2319196464","https://openalex.org/W2779618882"],"abstract_inverted_index":{"The":[0,37,47],"safety":[1,48],"and":[2,7,24,41],"reliability":[3],"of":[4,15,22,28,34,39],"reactor":[5,16],"instruments":[6,35],"redundant":[8,53],"systems":[9],"are":[10,50],"described":[11],"by":[12,19,25],"the":[13,26],"rate":[14],"shutdowns":[17],"caused":[18],"safe":[20],"failures":[21,33],"instruments,":[23],"length":[27],"time":[29],"during":[30,43],"which":[31],"unsafe":[32],"exist.":[36],"effect":[38],"repair":[40],"test":[42],"operation":[44],"is":[45],"considered.":[46],"parameters":[49],"determined":[51],"for":[52],"n-out-":[54],"of-m''":[55],"systems.":[56],"(auth)":[57]},"cited_by_api_url":"https://api.openalex.org/works?filter=cites:W24788753","counts_by_year":[{"year":2019,"cited_by_count":1},{"year":2016,"cited_by_count":1}],"updated_date":"2026-11-21T10:27:49.728292","created_date":"2016-06-24T00:00:00"}
