{"id":"https://openalex.org/W244618929","doi":null,"title":"Zastosowanie t\u0142umik\u00f3w pasywnych, quasi-aktywnych i hybrydowych do redukcji drga\u0144 sejsmicznych i parasejsmicznych budowli \u2013 przegl\u0105d rozwi\u0105za\u0144","display_name":"Zastosowanie t\u0142umik\u00f3w pasywnych, quasi-aktywnych i hybrydowych do redukcji drga\u0144 sejsmicznych i parasejsmicznych budowli \u2013 przegl\u0105d rozwi\u0105za\u0144","alternate_titles":[],"publication_year":2010,"publication_date":"2010-01-01","ids":{"openalex":"https://openalex.org/W244618929","mag":"244618929"},"language":"pl","primary_location":{"id":"pmh:oai:suw.biblos.pk.edu.pl:2257","doi":null,"is_oa":true,"landing_page_url":"http://suw.biblos.pk.edu.pl/resourceDetails&rId=2257","pdf_url":"https://repozytorium.biblos.pk.edu.pl/redo/resources/32737/file/suwFiles/KaweckiJ_ZastosowanieTlumikow.pdf","source":{"id":"https://openalex.org/S7407064259","display_name":"Repozytorium Politechniki Krakowskiej","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":null},"parent_works":[],"lineage":["https://openalex.org/W244618929"],"child_works_count":0,"pull_notice_works":[],"type":"article","is_traditional":true,"indexed_in":[],"open_access":{"is_oa":true,"oa_status":"green","oa_url":"https://repozytorium.biblos.pk.edu.pl/redo/resources/32737/file/suwFiles/KaweckiJ_ZastosowanieTlumikow.pdf","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5016546072","display_name":"Janusz Kawecki","type":null,"orcid":null,"observed_orcids":[]},"acted_on_behalf_of":[],"institutions":[],"countries":[],"is_corresponding":false,"contributor_roles":[],"raw_author_name":"Janusz Kawecki","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"last","author":{"id":"https://openalex.org/A5028990552","display_name":"Ryszard Mas\u0142owski","type":null,"orcid":"https://orcid.org/0000-0002-6877-7276","observed_orcids":["https://orcid.org/0000-0002-6877-7276"]},"acted_on_behalf_of":[],"institutions":[],"countries":[],"is_corresponding":false,"contributor_roles":[],"raw_author_name":"Ryszard Mas\u0142owski","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]}],"institutions":[],"countries_distinct_count":0,"institutions_distinct_count":0,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":true,"cited_by_count":4,"reviewed_by_count":0,"citation_normalized_percentile":{"value":0.0,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":88,"max":93},"biblio":{"volume":null,"issue":null,"first_page":"59","last_page":"67"},"is_retracted":false,"is_pulled":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10690","display_name":"Vibration Control and Rheological Fluids","score":0.9970999956130981,"subfield":{"id":"https://openalex.org/subfields/2205","display_name":"Civil and Structural Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10690","display_name":"Vibration Control and Rheological Fluids","score":0.9970999956130981,"subfield":{"id":"https://openalex.org/subfields/2205","display_name":"Civil and Structural Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10160","display_name":"Seismic Performance and Analysis","score":0.0015999999595806003,"subfield":{"id":"https://openalex.org/subfields/2205","display_name":"Civil and Structural Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T13852","display_name":"Seismic and Structural Analysis of Tall Buildings","score":9.999999747378752e-05,"subfield":{"id":"https://openalex.org/subfields/2205","display_name":"Civil and Structural Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/hybrid-damper","display_name":"hybrid damper","score":0.9549999833106995},{"id":"https://openalex.org/keywords/wind-induced-vibration","display_name":"wind-induced vibration","score":0.699999988079071},{"id":"https://openalex.org/keywords/structural-vibration-control","display_name":"structural vibration control","score":0.7149999737739563}],"concepts":[{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.40131473541259766}],"mesh":[],"locations_count":2,"locations":[{"id":"pmh:oai:suw.biblos.pk.edu.pl:2257","doi":null,"is_oa":true,"landing_page_url":"http://suw.biblos.pk.edu.pl/resourceDetails&rId=2257","pdf_url":"https://repozytorium.biblos.pk.edu.pl/redo/resources/32737/file/suwFiles/KaweckiJ_ZastosowanieTlumikow.pdf","source":{"id":"https://openalex.org/S7407064259","display_name":"Repozytorium Politechniki Krakowskiej","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":null},{"id":"mag:244618929","doi":null,"is_oa":false,"landing_page_url":"https://suw.biblos.pk.edu.pl/resourceDetailsBPP&rId=25043","pdf_url":null,"source":{"id":"https://openalex.org/S4306507486","display_name":"Czasopismo Techniczne. Budownictwo","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"journal"},"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false,"raw_source_name":"Czasopismo Techniczne. Budownictwo","raw_type":null}],"best_oa_location":{"id":"pmh:oai:suw.biblos.pk.edu.pl:2257","doi":null,"is_oa":true,"landing_page_url":"http://suw.biblos.pk.edu.pl/resourceDetails&rId=2257","pdf_url":"https://repozytorium.biblos.pk.edu.pl/redo/resources/32737/file/suwFiles/KaweckiJ_ZastosowanieTlumikow.pdf","source":{"id":"https://openalex.org/S7407064259","display_name":"Repozytorium Politechniki Krakowskiej","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":null},"sustainable_development_goals":[{"score":0.4000000059604645,"id":"https://metadata.un.org/sdg/11","display_name":"Sustainable cities and communities"}],"study_designs":[],"awards":[],"funders":[],"has_content":{"grobid_xml":true,"pdf":true},"content_urls":{"pdf":"https://content.openalex.org/works/W244618929.pdf","grobid_xml":"https://content.openalex.org/works/W244618929.grobid-xml"},"referenced_works_count":3,"referenced_works":["https://openalex.org/W1515157833","https://openalex.org/W1984484262","https://openalex.org/W2072712497"],"related_works":["https://openalex.org/W4405677130","https://openalex.org/W89283860","https://openalex.org/W7033874953","https://openalex.org/W1601272113","https://openalex.org/W993234083","https://openalex.org/W1038302039","https://openalex.org/W1475817309","https://openalex.org/W3198253575","https://openalex.org/W3217038324","https://openalex.org/W806019919"],"abstract_inverted_index":{"R\u00f3\u017cnego":[0],"rodzaju":[1],"t\u0142umiki":[2,51],"drga\u0144":[3,12,63],"s\u0105":[4],"od":[5],"wielu":[6],"lat":[7],"stosowane":[8],"w":[9,28,48],"celu":[10],"redukcji":[11,62],"budowli":[13],"wywo\u0142ywanych":[14],"oddzia\u0142ywaniami":[15],"dynamicznymi":[16],"wiatru,":[17],"sejsmicznymi":[18],"i":[19,37,54,65],"parasejsmicznymi.":[20],"W":[21],"ostatnich":[22],"latach":[23],"mo\u017cna":[24],"zaobserwowa\u0107":[25],"znacz\u0105cy":[26],"rozw\u00f3j":[27],"tej":[29],"dziedzinie.":[30],"Dotyczy":[31],"to":[32],"zar\u00f3wno":[33],"prac":[34],"teoretycznych,":[35],"jak":[36],"rozwi\u0105za\u0144":[38],"praktycznych.":[39],"Prezentowany":[40],"artyku\u0142":[41],"ma":[42],"charakter":[43],"przegl\u0105dowy.":[44],"Szczeg\u00f3ln\u0105":[45],"uwag\u0119":[46],"zwr\u00f3cono":[47],"nim":[49],"na":[50],"pasywne,":[52],"hybrydowe":[53],"quasi-aktywne.":[55],"Mog\u0105":[56],"one":[57],"bowiem":[58],"znale\u017a\u0107":[59],"zastosowanie":[60],"do":[61],"sejsmicznych":[64],"parasejsmicznych.":[66]},"cited_by_api_url":"https://api.openalex.org/works?filter=cites:W244618929","counts_by_year":[{"year":2019,"cited_by_count":2},{"year":2016,"cited_by_count":1},{"year":2014,"cited_by_count":1}],"updated_date":"2026-11-25T09:40:18.809321","created_date":"2016-06-24T00:00:00"}