{"id":"https://openalex.org/W2430249690","doi":null,"title":"[Comparative assessment of ambulatory blood pressure monitoring and blood pressure measurement by the patient at home].","display_name":"[Comparative assessment of ambulatory blood pressure monitoring and blood pressure measurement by the patient at home].","publication_year":1999,"publication_date":"1999-10-21","ids":{"openalex":"https://openalex.org/W2430249690","mag":"2430249690","pmid":"https://pubmed.ncbi.nlm.nih.gov/10568352"},"language":"de","primary_location":{"id":"pmid:10568352","doi":null,"is_oa":false,"landing_page_url":"https://pubmed.ncbi.nlm.nih.gov/10568352","pdf_url":null,"source":{"id":"https://openalex.org/S4306525036","display_name":"PubMed","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I1299303238","host_organization_name":"National Institutes of Health","host_organization_lineage":["https://openalex.org/I1299303238"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Praxis","raw_type":"Comparative Study"},"volume":null,"type":"article","is_traditional":true,"indexed_in":["pubmed"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5110058609","display_name":"Raffaele Daniele Siciliano","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I4210100468","display_name":"University Hospital Zurich","ror":"https://ror.org/01462r250","country_code":"CH","type":"healthcare","lineage":["https://openalex.org/I4210100468"]}],"countries":["CH"],"is_corresponding":false,"raw_author_name":"R D Siciliano","raw_affiliation_strings":["Departement f\u00fcr Innere Medizin, Universit\u00e4tsspital Z\u00fcrich"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Departement f\u00fcr Innere Medizin, Universit\u00e4tsspital Z\u00fcrich","institution_ids":["https://openalex.org/I4210100468"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5111483722","display_name":"W. Vetter","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"W Vetter","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":{"value":0.37838873,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":"88","issue":"43","first_page":"1751","last_page":"8"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10144","display_name":"Blood Pressure and Hypertension Studies","score":0.9980000257492065,"subfield":{"id":"https://openalex.org/subfields/2705","display_name":"Cardiology and Cardiovascular Medicine"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},"topics":[{"id":"https://openalex.org/T10144","display_name":"Blood Pressure and Hypertension Studies","score":0.9980000257492065,"subfield":{"id":"https://openalex.org/subfields/2705","display_name":"Cardiology and Cardiovascular Medicine"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},{"id":"https://openalex.org/T11196","display_name":"Non-Invasive Vital Sign Monitoring","score":0.0010999999940395355,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10924","display_name":"Cardiovascular Health and Disease Prevention","score":9.999999747378752e-05,"subfield":{"id":"https://openalex.org/subfields/2705","display_name":"Cardiology and Cardiovascular Medicine"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/ambulatory-blood-pressure-monitoring","display_name":"ambulatory blood pressure monitoring","score":1.0},{"id":"https://openalex.org/keywords/self-monitoring-of-blood-pressure","display_name":"self-measured blood pressure","score":0.9139999747276306},{"id":"https://openalex.org/keywords/home-blood-pressure-monitoring","display_name":"home blood pressure monitoring","score":0.875},{"id":"https://openalex.org/keywords/24-hour-ambulatory-blood-pressure","display_name":"24-hour ambulatory blood pressure","score":0.9039999842643738},{"id":"https://openalex.org/keywords/systolic-blood-pressure","display_name":"systolic blood pressure","score":0.7860000133514404},{"id":"https://openalex.org/keywords/diastolic-blood-pressure","display_name":"diastolic blood pressure","score":1.0},{"id":"https://openalex.org/keywords/method-comparison","display_name":"method comparison","score":0.6209999918937683}],"concepts":[{"id":"https://openalex.org/C149323552","wikidata":"https://www.wikidata.org/wiki/Q3090739","display_name":"Ambulatory blood pressure","level":3,"score":0.8415842056274414},{"id":"https://openalex.org/C19720800","wikidata":"https://www.wikidata.org/wiki/Q7722","display_name":"Morning","level":2,"score":0.8156044483184814},{"id":"https://openalex.org/C2910533495","wikidata":"https://www.wikidata.org/wiki/Q503968","display_name":"Sphygmomanometer","level":3,"score":0.7856253385543823},{"id":"https://openalex.org/C84393581","wikidata":"https://www.wikidata.org/wiki/Q82642","display_name":"Blood pressure","level":2,"score":0.7487520575523376},{"id":"https://openalex.org/C71924100","wikidata":"https://www.wikidata.org/wiki/Q11190","display_name":"Medicine","level":0,"score":0.6565358638763428},{"id":"https://openalex.org/C164705383","wikidata":"https://www.wikidata.org/wiki/Q10379","display_name":"Cardiology","level":1,"score":0.6152569651603699},{"id":"https://openalex.org/C57900726","wikidata":"https://www.wikidata.org/wiki/Q492905","display_name":"Diastole","level":3,"score":0.5651180744171143},{"id":"https://openalex.org/C35785553","wikidata":"https://www.wikidata.org/wiki/Q756720","display_name":"Ambulatory","level":2,"score":0.5293945670127869},{"id":"https://openalex.org/C126322002","wikidata":"https://www.wikidata.org/wiki/Q11180","display_name":"Internal medicine","level":1,"score":0.4940393269062042}],"mesh":[{"descriptor_ui":"D000328","descriptor_name":"Adult","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D000368","descriptor_name":"Aged","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D003971","descriptor_name":"Diastole","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D005260","descriptor_name":"Female","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D006801","descriptor_name":"Humans","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D008297","descriptor_name":"Male","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D008875","descriptor_name":"Middle Aged","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D012648","descriptor_name":"Self Care","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D013599","descriptor_name":"Systole","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D015924","descriptor_name":"Blood Pressure Monitors","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D018660","descriptor_name":"Blood Pressure Monitoring, Ambulatory","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":true},{"descriptor_ui":"D018660","descriptor_name":"Blood Pressure Monitoring, Ambulatory","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":true}],"locations_count":2,"locations":[{"id":"pmid:10568352","doi":null,"is_oa":false,"landing_page_url":"https://pubmed.ncbi.nlm.nih.gov/10568352","pdf_url":null,"source":{"id":"https://openalex.org/S4306525036","display_name":"PubMed","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I1299303238","host_organization_name":"National Institutes of Health","host_organization_lineage":["https://openalex.org/I1299303238"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Praxis","raw_type":"Comparative Study"},{"id":"mag:2430249690","doi":null,"is_oa":false,"landing_page_url":"https://pubmed.ncbi.nlm.nih.gov/10568352","pdf_url":null,"source":{"id":"https://openalex.org/S4306525036","display_name":"PubMed","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I1299303238","host_organization_name":"National Institutes of Health","host_organization_lineage":["https://openalex.org/I1299303238"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false,"raw_source_name":"PubMed","raw_type":null}],"best_oa_location":null,"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/3","display_name":"Good health and well-being","score":0.98580002784729}],"study_designs":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":0,"referenced_works":[],"related_works":["https://openalex.org/W2111270559","https://openalex.org/W2415921409","https://openalex.org/W2087523403","https://openalex.org/W7000621498","https://openalex.org/W2026802540","https://openalex.org/W2331006526","https://openalex.org/W2406033329","https://openalex.org/W1977811047","https://openalex.org/W137168755","https://openalex.org/W2061476198"],"abstract_inverted_index":{"Ambulatory":[0],"blood":[1,12,197],"pressure":[2,13,198],"monitoring":[3],"(ABPM)":[4],"over":[5,83,99],"24":[6,58,64,141],"hours":[7],"was":[8,26,47,105,126,153,169],"compared":[9],"to":[10,207],"two":[11,102],"measurements":[14],"taken":[15],"in":[16,185],"the":[17,20,30,33,36,62,69,74,84,96,100,109,129,134,138,144,148,164,186],"morning":[18,187],"by":[19],"22":[21],"test":[22,85],"persons":[23],"themselves.":[24],"ABPM":[25,140,152,168,182],"carried":[27],"out":[28],"at":[29],"beginning":[31],"and":[32,56,61,92,183,193,204],"end":[34],"of":[35,89,133,163,195],"study":[37],"using":[38],"a":[39,117,202],"spacelabs":[40],"SL":[41],"90207":[42],"apparatus.":[43],"A":[44],"semiautomatic":[45,196],"sphygmomanometer":[46],"used":[48],"for":[49,147],"self-measurements":[50,184],"(Visomat":[51],"OZ":[52],"2).":[53],"Monitored":[54],"systolic":[55,91,131],"diastolic":[57,93,165],"hour":[59,65,142],"values":[60,82,94,112,166],"mean":[63,88,130,139],"value":[66,132],"were":[67],"on":[68],"average":[70],"slightly":[71],"higher":[72],"than":[73,108],"self-measured":[75,90],"pressures.":[76],"Both":[77],"methods":[78],"yielded":[79],"almost":[80],"constant":[81],"period.":[86],"The":[87,161,191],"from":[95],"second":[97,135],"measurement":[98,150],"entire":[101],"week":[103],"period":[104],"significantly":[106],"lower":[107,154,171],"initially":[110],"registered":[111],"(p":[113],"<":[114,124,159,176],"0.001).":[115],"Therefore":[116],"high":[118],"correlation":[119,146,162],"(r":[120,155,172],"=":[121,156,173],"0.88,":[122],"p":[123,158,175],"0.001)":[125],"found":[127],"between":[128],"self-measurement":[136],"with":[137,151,167],"value;":[143],"corresponding":[145],"first":[149],"0.84,":[157],"0.01).":[160,177],"also":[170],"0.70,":[174],"These":[178],"results":[179],"show":[180],"that":[181],"differ":[188],"only":[189],"slightly.":[190],"use":[192],"reliability":[194],"measuring":[199],"devices":[200],"provide":[201],"practicable":[203],"economic":[205],"alternative":[206],"ABPM.":[208]},"counts_by_year":[],"updated_date":"2026-10-31T12:09:11.096373","created_date":"2016-06-24T00:00:00"}
