{"id":"https://openalex.org/W2425555484","doi":null,"title":"Electromagnetic interference by GSM cellular phones and UHF radios with intensive-care and operating-room ventilators.","display_name":"Electromagnetic interference by GSM cellular phones and UHF radios with intensive-care and operating-room ventilators.","alternate_titles":[],"publication_year":2000,"publication_date":"2000-09-01","ids":{"openalex":"https://openalex.org/W2425555484","mag":"2425555484","pmid":"https://pubmed.ncbi.nlm.nih.gov/11098392"},"language":"en","primary_location":{"id":"pmid:11098392","doi":null,"is_oa":false,"landing_page_url":"https://pubmed.ncbi.nlm.nih.gov/11098392","pdf_url":null,"source":{"id":"https://openalex.org/S4306525036","display_name":"PubMed","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I1299303238","host_organization_name":"National Institutes of Health","host_organization_lineage":["https://openalex.org/I1299303238"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Biomedical instrumentation & technology","raw_type":"Evaluation Study"},"parent_works":[],"lineage":["https://openalex.org/W2425555484"],"child_works_count":0,"pull_notice_works":[],"type":"article","is_traditional":true,"indexed_in":["pubmed"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5040966366","display_name":"Vanessa Barbaro","type":null,"orcid":"https://orcid.org/0000-0001-8760-2343","observed_orcids":["https://orcid.org/0000-0001-8760-2343"]},"acted_on_behalf_of":[],"institutions":[{"id":"https://openalex.org/I27897274","display_name":"Istituto Superiore di Sanit\u00e0","ror":"https://ror.org/02hssy432","country_code":"IT","type":"government","lineage":["https://openalex.org/I27897274"]}],"countries":["IT"],"is_corresponding":false,"contributor_roles":[],"raw_author_name":"V Barbaro","raw_affiliation_strings":["Biomedical Engineering Laboratory, Istituto Superiore di Sanit\u00e0, Rome, Italy","Biomedical Engineering Laboratory, Istituto Superiore di Sanita\u2019, Rome, Italy"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Biomedical Engineering Laboratory, Istituto Superiore di Sanit\u00e0, Rome, Italy","institution_ids":["https://openalex.org/I27897274"]},{"raw_affiliation_string":"Biomedical Engineering Laboratory, Istituto Superiore di Sanita\u2019, Rome, Italy","institution_ids":["https://openalex.org/I27897274"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5039619216","display_name":"Pietro Bartolini","type":null,"orcid":null,"observed_orcids":[]},"acted_on_behalf_of":[],"institutions":[],"countries":[],"is_corresponding":false,"contributor_roles":[],"raw_author_name":"P Bartolini","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"middle","author":{"id":"https://openalex.org/A5015554984","display_name":"Marcello Benassi","type":null,"orcid":null,"observed_orcids":[]},"acted_on_behalf_of":[],"institutions":[],"countries":[],"is_corresponding":false,"contributor_roles":[],"raw_author_name":"M Benassi","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"middle","author":{"id":"https://openalex.org/A5053129055","display_name":"Anna Maria Di Nallo","type":null,"orcid":null,"observed_orcids":[]},"acted_on_behalf_of":[],"institutions":[],"countries":[],"is_corresponding":false,"contributor_roles":[],"raw_author_name":"A M Di Nallo","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"middle","author":{"id":"https://openalex.org/A5008784119","display_name":"L Reali","type":null,"orcid":null,"observed_orcids":[]},"acted_on_behalf_of":[],"institutions":[],"countries":[],"is_corresponding":false,"contributor_roles":[],"raw_author_name":"L Reali","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"last","author":{"id":"https://openalex.org/A5059860861","display_name":"Sergio Valsecchi","type":null,"orcid":"https://orcid.org/0000-0001-7055-6942","observed_orcids":["https://orcid.org/0000-0001-7055-6942"]},"acted_on_behalf_of":[],"institutions":[],"countries":[],"is_corresponding":false,"contributor_roles":[],"raw_author_name":"S Valsecchi","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":3.3622,"has_fulltext":false,"cited_by_count":35,"reviewed_by_count":0,"citation_normalized_percentile":{"value":0.90485437,"is_in_top_1_percent":false,"is_in_top_10_percent":true},"cited_by_percentile_year":{"min":87,"max":96},"biblio":{"volume":"34","issue":"5","first_page":"361","last_page":"369"},"is_retracted":false,"is_pulled":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T13690","display_name":"Quality and Safety in Healthcare","score":0.45260000228881836,"subfield":{"id":"https://openalex.org/subfields/3607","display_name":"Medical Laboratory Technology"},"field":{"id":"https://openalex.org/fields/36","display_name":"Health Professions"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},"topics":[{"id":"https://openalex.org/T13690","display_name":"Quality and Safety in Healthcare","score":0.45260000228881836,"subfield":{"id":"https://openalex.org/subfields/3607","display_name":"Medical Laboratory Technology"},"field":{"id":"https://openalex.org/fields/36","display_name":"Health Professions"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},{"id":"https://openalex.org/T13248","display_name":"Healthcare Technology and Patient Monitoring","score":0.25,"subfield":{"id":"https://openalex.org/subfields/2718","display_name":"Health Informatics"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},{"id":"https://openalex.org/T11444","display_name":"Electromagnetic Compatibility and Noise Suppression","score":0.19619999825954437,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/electromagnetic-interference","display_name":"electromagnetic interference","score":0.9980000257492065},{"id":"https://openalex.org/keywords/uhf-radio","display_name":"UHF radio","score":0.9290000200271606},{"id":"https://openalex.org/keywords/mechanical-ventilators","display_name":"ventilators","score":0.781000018119812},{"id":"https://openalex.org/keywords/interference-distance","display_name":"interference distance","score":0.5070000290870667},{"id":"https://openalex.org/keywords/medical-device-safety","display_name":"medical device safety","score":0.5139999985694885},{"id":"https://openalex.org/keywords/electromagnetic-compatibility","display_name":"electromagnetic compatibility","score":0.42800000309944153}],"concepts":[{"id":"https://openalex.org/C2779971919","wikidata":"https://www.wikidata.org/wiki/Q1378949","display_name":"Handset","level":2,"score":0.7646118402481079},{"id":"https://openalex.org/C184892835","wikidata":"https://www.wikidata.org/wiki/Q1474513","display_name":"Electromagnetic interference","level":2,"score":0.7340312600135803},{"id":"https://openalex.org/C43461449","wikidata":"https://www.wikidata.org/wiki/Q2495531","display_name":"EMI","level":3,"score":0.6985788941383362},{"id":"https://openalex.org/C59201141","wikidata":"https://www.wikidata.org/wiki/Q46904","display_name":"GSM","level":2,"score":0.6172571778297424},{"id":"https://openalex.org/C96122199","wikidata":"https://www.wikidata.org/wiki/Q628096","display_name":"Ultra high frequency","level":2,"score":0.6155257821083069},{"id":"https://openalex.org/C32022120","wikidata":"https://www.wikidata.org/wiki/Q797225","display_name":"Interference (communication)","level":3,"score":0.6111091375350952},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.3990047872066498},{"id":"https://openalex.org/C76155785","wikidata":"https://www.wikidata.org/wiki/Q418","display_name":"Telecommunications","level":1,"score":0.39417704939842224},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.3733339309692383},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.29375892877578735},{"id":"https://openalex.org/C127162648","wikidata":"https://www.wikidata.org/wiki/Q16858953","display_name":"Channel (broadcasting)","level":2,"score":0.09849938750267029}],"mesh":[{"descriptor_ui":"D004574","descriptor_name":"Electromagnetic Fields","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D004868","descriptor_name":"Equipment Failure","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D007362","descriptor_name":"Intensive Care Units","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D007558","descriptor_name":"Italy","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D009873","descriptor_name":"Operating Rooms","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D011846","descriptor_name":"Radio Waves","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D012121","descriptor_name":"Respiration, Artificial","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":true},{"descriptor_ui":"D013689","descriptor_name":"Telephone","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D018570","descriptor_name":"Risk Assessment","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false}],"locations_count":2,"locations":[{"id":"pmid:11098392","doi":null,"is_oa":false,"landing_page_url":"https://pubmed.ncbi.nlm.nih.gov/11098392","pdf_url":null,"source":{"id":"https://openalex.org/S4306525036","display_name":"PubMed","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I1299303238","host_organization_name":"National Institutes of Health","host_organization_lineage":["https://openalex.org/I1299303238"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Biomedical instrumentation & technology","raw_type":"Evaluation Study"},{"id":"mag:2425555484","doi":null,"is_oa":false,"landing_page_url":"https://pubmed.ncbi.nlm.nih.gov/11098392","pdf_url":null,"source":{"id":"https://openalex.org/S4306525036","display_name":"PubMed","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I1299303238","host_organization_name":"National Institutes of Health","host_organization_lineage":["https://openalex.org/I1299303238"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false,"raw_source_name":"PubMed","raw_type":null}],"best_oa_location":null,"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/3","display_name":"Good health and well-being","score":0.9763000011444092}],"study_designs":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":0,"referenced_works":[],"related_works":["https://openalex.org/W7037654989","https://openalex.org/W1578037634","https://openalex.org/W125354534","https://openalex.org/W2313867377","https://openalex.org/W2057350604","https://openalex.org/W1984164849","https://openalex.org/W1997313707","https://openalex.org/W4298260937","https://openalex.org/W2189156753","https://openalex.org/W2544452811"],"abstract_inverted_index":{"The":[0,84],"aim":[1],"of":[2,69,82,86,102,125],"this":[3],"study":[4],"was":[5,93],"to":[6,134],"evaluate":[7],"the":[8,12,43,54,63,67],"risks":[9],"deriving":[10],"from":[11],"interference":[13,50,58],"by":[14,89],"radio":[15],"handsets":[16],"(GSM":[17],"cellular":[18],"phones":[19],"and":[20,25,78,95,105,132],"UHF":[21],"radios)":[22],"with":[23,42,110],"intensive-care":[24],"operating-room":[26],"ventilators.":[27],"Tests":[28],"were":[29,107,120],"conducted":[30],"in":[31,34,40,75],"three":[32,123],"hospitals":[33],"Rome":[35],"on":[36],"22":[37],"lung":[38],"ventilators":[39,124],"accordance":[41],"recommended":[44],"practice":[45],"ANSI":[46],"C63.18-1997.":[47],"When":[48],"electromagnetic":[49],"(EMI)":[51],"effects":[52,119],"occurred,":[53],"authors":[55],"determined":[56],"maximum":[57],"distances.":[59],"They":[60],"also":[61],"evaluated":[62],"distances":[64,97],"at":[65,113],"which":[66],"use":[68],"a":[70,76,79,114,126],"given":[71],"handset":[72],"would":[73],"result":[74],"5%":[77],"95%":[80],"probability":[81],"interference.":[83],"degree":[85],"risk":[87],"posed":[88],"each":[90],"observed":[91,108,118],"event":[92],"estimated,":[94],"safe":[96],"are":[98],"suggested.":[99],"EMI":[100],"events":[101],"varying":[103],"degrees":[104],"natures":[106],"even":[109],"transmitters":[111],"placed":[112],"considerable":[115],"distance.":[116],"All":[117],"temporary.":[121],"Only":[122],"certain":[127],"model":[128],"stopped":[129],"working":[130],"altogether":[131],"had":[133],"be":[135],"reset.":[136]},"cited_by_api_url":"https://api.openalex.org/works?filter=cites:W2425555484","counts_by_year":[{"year":2016,"cited_by_count":3},{"year":2013,"cited_by_count":3},{"year":2012,"cited_by_count":1}],"updated_date":"2026-11-24T14:10:38.155754","created_date":"2016-06-24T00:00:00"}
