{"id":"https://openalex.org/W24136647","doi":null,"title":"Specification of computer-aided design of transmission protection systems. Final report","display_name":"Specification of computer-aided design of transmission protection systems. Final report","alternate_titles":[],"publication_year":1984,"publication_date":"1984-01-01","ids":{"openalex":"https://openalex.org/W24136647","mag":"24136647"},"language":"en","primary_location":{"id":"mag:24136647","doi":null,"is_oa":false,"landing_page_url":"http://www.osti.gov/scitech/biblio/5349539","pdf_url":null,"source":{"id":"https://openalex.org/S4306402487","display_name":"OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I139351228","host_organization_name":"Office of Scientific and Technical Information","host_organization_lineage":["https://openalex.org/I139351228"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":null},"parent_works":[],"lineage":["https://openalex.org/W24136647"],"child_works_count":0,"type":"report","is_traditional":false,"indexed_in":[],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5034851423","display_name":"Mark J. Damborg","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"contributor_roles":[],"raw_author_name":"M.J. Damborg","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"last","author":{"id":"https://openalex.org/A5114013712","display_name":"S Venkata","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"contributor_roles":[],"raw_author_name":"S Venkata","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]}],"institutions":[],"countries_distinct_count":0,"institutions_distinct_count":0,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":null,"has_fulltext":true,"cited_by_count":33,"reviewed_by_count":0,"citation_normalized_percentile":null,"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":null,"last_page":null},"is_retracted":false,"is_pulled":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10972","display_name":"Power Systems Fault Detection","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10972","display_name":"Power Systems Fault Detection","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10305","display_name":"Power System Optimization and Stability","score":0.0,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12451","display_name":"Smart Grid and Power Systems","score":0.0,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/computer-aided-design","display_name":"computer-aided design","score":0.9169999957084656},{"id":"https://openalex.org/keywords/protection-coordination","display_name":"protection coordination","score":0.9319999814033508},{"id":"https://openalex.org/keywords/directional-relays","display_name":"directional relays","score":0.8799999952316284},{"id":"https://openalex.org/keywords/overcurrent-relays","display_name":"overcurrent relays","score":0.9179999828338623},{"id":"https://openalex.org/keywords/distance-relays","display_name":"distance relays","score":0.8659999966621399},{"id":"https://openalex.org/keywords/human-machine-interaction","display_name":"human-machine interaction","score":0.6620000004768372},{"id":"https://openalex.org/keywords/network-analysis-algorithms","display_name":"network analysis algorithms","score":0.8339999914169312},{"id":"https://openalex.org/keywords/relational-database-design","display_name":"relational database design","score":0.7269999980926514},{"id":"https://openalex.org/keywords/power-system-protection","display_name":"power system protection","score":0.5630000233650208}],"concepts":[{"id":"https://openalex.org/C2780945871","wikidata":"https://www.wikidata.org/wiki/Q194274","display_name":"Backup","level":2,"score":0.7376884818077087},{"id":"https://openalex.org/C47949032","wikidata":"https://www.wikidata.org/wiki/Q663542","display_name":"Overcurrent","level":3,"score":0.7207260131835938},{"id":"https://openalex.org/C194789388","wikidata":"https://www.wikidata.org/wiki/Q17855283","display_name":"CAD","level":2,"score":0.6020115613937378},{"id":"https://openalex.org/C2778156585","wikidata":"https://www.wikidata.org/wiki/Q174053","display_name":"Relay","level":3,"score":0.5888196229934692},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.5264756679534912},{"id":"https://openalex.org/C119823426","wikidata":"https://www.wikidata.org/wiki/Q184793","display_name":"Computer Aided Design","level":2,"score":0.4977705776691437},{"id":"https://openalex.org/C45235069","wikidata":"https://www.wikidata.org/wiki/Q278425","display_name":"Table (database)","level":2,"score":0.4852294921875},{"id":"https://openalex.org/C2780727963","wikidata":"https://www.wikidata.org/wiki/Q5157368","display_name":"Computer-aided","level":2,"score":0.42914479970932007},{"id":"https://openalex.org/C199639397","wikidata":"https://www.wikidata.org/wiki/Q1788588","display_name":"Engineering drawing","level":1,"score":0.32513561844825745},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.3058973550796509},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.22521156072616577},{"id":"https://openalex.org/C77088390","wikidata":"https://www.wikidata.org/wiki/Q8513","display_name":"Database","level":1,"score":0.17534667253494263},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.12149029970169067},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.10747197270393372},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C199360897","wikidata":"https://www.wikidata.org/wiki/Q9143","display_name":"Programming language","level":1,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"mag:24136647","doi":null,"is_oa":false,"landing_page_url":"http://www.osti.gov/scitech/biblio/5349539","pdf_url":null,"source":{"id":"https://openalex.org/S4306402487","display_name":"OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I139351228","host_organization_name":"Office of Scientific and Technical Information","host_organization_lineage":["https://openalex.org/I139351228"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":null}],"best_oa_location":null,"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/9","score":0.4943999946117401,"display_name":"Industry, innovation and infrastructure"}],"study_designs":[],"awards":[{"id":"https://openalex.org/G1580691456","display_name":"Cell invasion, motility, and proliferation level estimate maps in gliomas","funder_award_id":"R21CA167354","funder_id":"https://openalex.org/F4320337351","funder_display_name":"National Cancer Institute"}],"funders":[{"id":"https://openalex.org/F4320337351","display_name":"National Cancer Institute","ror":"https://ror.org/040gcmg81"}],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":0,"referenced_works":[],"related_works":["https://openalex.org/W2337257338","https://openalex.org/W2164039877","https://openalex.org/W2066056667","https://openalex.org/W2070853452","https://openalex.org/W2153897944","https://openalex.org/W2127959104","https://openalex.org/W2071718236","https://openalex.org/W2069107421","https://openalex.org/W2069784944","https://openalex.org/W1990249410"],"abstract_inverted_index":{"The":[0,37,161,187],"most":[1],"tedious":[2],"and":[3,11,20,50,69,73,76,92,127,132,156],"time-consuming":[4],"task":[5],"for":[6,57,66,74,104,111,124,130,184,214],"protection":[7,26,106,208],"engineers":[8],"is":[9,16,175,218],"selecting":[10],"setting":[12],"protective":[13],"relays.":[14],"It":[15,174],"shown":[17],"that":[18,177],"this":[19],"many":[21],"other":[22],"tasks":[23],"of":[24,39,122,148,151,207],"the":[25,32,47,99,105,141,152,215],"engineer":[27],"can":[28],"be":[29,182,212],"relieved":[30],"by":[31,171],"computer-aided":[33],"design":[34,202],"(CAD)":[35],"concept.":[36],"requirements":[38],"such":[40],"a":[41,86,144,149],"CAD":[42,82,107,216],"system":[43,83,146,217],"are":[44,55,64,163],"specified.":[45],"In":[46],"process,":[48],"complete":[49],"precise":[51],"primary/backup":[52],"coordination":[53,115,170],"criteria":[54],"identified":[56],"directional":[58],"relays":[59,72,142],"on":[60,143],"transmission":[61],"networks.":[62],"Criteria":[63],"included":[65],"both":[67],"overcurrent":[68,131],"3-zone":[70],"distance":[71,133],"two":[75],"three":[77],"terminal":[78],"lines.":[79],"A":[80,198],"successful":[81],"depends":[84],"upon":[85],"suitable":[87],"man-machine":[88,101],"dialog,":[89],"effective":[90],"algorithms":[91,120,137],"convenient":[93],"data":[94,179,185,195,200,209],"management.":[95,186],"We":[96],"have":[97,116],"begun":[98],"appropriate":[100],"dialog":[102],"structuring":[103],"system.":[108,160],"Algorithms":[109],"necessary":[110,213],"computer":[112],"aided":[113],"relay":[114,134],"been":[117,191],"developed.":[118],"These":[119,136],"consist":[121],"one":[123,128],"network":[125],"analysis":[126],"each":[129],"coordination.":[135],"will":[138],"successfully":[139],"coordinate":[140],"test":[145],"consisting":[147],"portion":[150],"Puget":[153],"Sound":[154],"Power":[155],"Light":[157],"Company's":[158],"115-kV":[159],"results":[162],"as":[164],"good":[165],"or":[166],"better":[167],"than":[168],"manual":[169],"experienced":[172],"engineers.":[173],"proposed":[176],"modern":[178],"base":[180,196,201],"methods":[181],"used":[183],"experimental":[188],"code":[189],"has":[190],"implemented":[192],"using":[193],"relational":[194],"software.":[197],"relationalmore\u00a0\u00bb":[199],"which":[203],"includes":[204],"all":[205],"types":[206],"expected":[210],"to":[211],"provided.\u00ab\u00a0less":[219]},"cited_by_api_url":"https://api.openalex.org/works?filter=cites:W24136647","counts_by_year":[{"year":2016,"cited_by_count":1}],"updated_date":"2026-11-16T12:05:36.265796","created_date":"2016-06-24T00:00:00"}
