{"id":"https://openalex.org/W2409545692","doi":null,"title":"Improving the accuracy of intraocular pressure readings.","display_name":"Improving the accuracy of intraocular pressure readings.","publication_year":2006,"publication_date":"2006-07-04","ids":{"openalex":"https://openalex.org/W2409545692","mag":"2409545692","pmid":"https://pubmed.ncbi.nlm.nih.gov/16850707"},"language":"en","primary_location":{"id":"pmid:16850707","doi":null,"is_oa":false,"landing_page_url":"https://pubmed.ncbi.nlm.nih.gov/16850707","pdf_url":null,"source":{"id":"https://openalex.org/S4306525036","display_name":"PubMed","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I1299303238","host_organization_name":"National Institutes of Health","host_organization_lineage":["https://openalex.org/I1299303238"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Nursing times","raw_type":"Journal Article"},"volume":null,"type":"article","is_traditional":true,"indexed_in":["pubmed"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5000949400","display_name":"Christopher Tattersall","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I2802640739","display_name":"Royal Glamorgan Hospital","ror":"https://ror.org/05nzesv70","country_code":"GB","type":"healthcare","lineage":["https://openalex.org/I2802640739"]}],"countries":["GB"],"is_corresponding":false,"raw_author_name":"Christopher Tattersall","raw_affiliation_strings":["Royal Glamorgan Hospital"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Royal Glamorgan Hospital","institution_ids":["https://openalex.org/I2802640739"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5108400781","display_name":"Stephen A Vernon","orcid":"https://orcid.org/0000-0003-3571-1788","observed_orcids":["https://orcid.org/0000-0003-3571-1788"]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Stephen Vernon","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"last","author":{"id":null,"display_name":"Cheryl Wood","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Cheryl Wood","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":1,"citation_normalized_percentile":{"value":0.53179191,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":88,"max":93},"biblio":{"volume":"102","issue":"27","first_page":"36","last_page":"8"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11314","display_name":"Clinical Laboratory Practices and Quality Control","score":0.35839998722076416,"subfield":{"id":"https://openalex.org/subfields/3607","display_name":"Medical Laboratory Technology"},"field":{"id":"https://openalex.org/fields/36","display_name":"Health Professions"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},"topics":[{"id":"https://openalex.org/T11314","display_name":"Clinical Laboratory Practices and Quality Control","score":0.35839998722076416,"subfield":{"id":"https://openalex.org/subfields/3607","display_name":"Medical Laboratory Technology"},"field":{"id":"https://openalex.org/fields/36","display_name":"Health Professions"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},{"id":"https://openalex.org/T11890","display_name":"Scientific Measurement and Uncertainty Evaluation","score":0.22789999842643738,"subfield":{"id":"https://openalex.org/subfields/3105","display_name":"Instrumentation"},"field":{"id":"https://openalex.org/fields/31","display_name":"Physics and Astronomy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T13690","display_name":"Quality and Safety in Healthcare","score":0.20970000326633453,"subfield":{"id":"https://openalex.org/subfields/3607","display_name":"Medical Laboratory Technology"},"field":{"id":"https://openalex.org/fields/36","display_name":"Health Professions"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/intraocular-pressure-measurement","display_name":"intraocular pressure measurement","score":0.8899999856948853},{"id":"https://openalex.org/keywords/tonometry","display_name":"tonometry","score":0.6759999990463257},{"id":"https://openalex.org/keywords/instrument-calibration","display_name":"instrument calibration","score":0.7559999823570251},{"id":"https://openalex.org/keywords/calibration-protocol","display_name":"calibration protocol","score":0.9150000214576721},{"id":"https://openalex.org/keywords/measurement-accuracy","display_name":"measurement accuracy","score":0.8799999952316284},{"id":"https://openalex.org/keywords/calibration-error","display_name":"calibration error","score":0.7699999809265137}],"concepts":[{"id":"https://openalex.org/C2780385302","wikidata":"https://www.wikidata.org/wiki/Q367158","display_name":"Protocol (science)","level":3,"score":0.8545712232589722},{"id":"https://openalex.org/C165838908","wikidata":"https://www.wikidata.org/wiki/Q736777","display_name":"Calibration","level":2,"score":0.6679205894470215},{"id":"https://openalex.org/C2781092963","wikidata":"https://www.wikidata.org/wiki/Q650050","display_name":"Intraocular pressure","level":2,"score":0.6150747537612915},{"id":"https://openalex.org/C71924100","wikidata":"https://www.wikidata.org/wiki/Q11190","display_name":"Medicine","level":0,"score":0.5389675498008728},{"id":"https://openalex.org/C3018023364","wikidata":"https://www.wikidata.org/wiki/Q425265","display_name":"Significant difference","level":2,"score":0.4603021740913391},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.3706379532814026},{"id":"https://openalex.org/C118487528","wikidata":"https://www.wikidata.org/wiki/Q161437","display_name":"Ophthalmology","level":1,"score":0.2986295819282532},{"id":"https://openalex.org/C105795698","wikidata":"https://www.wikidata.org/wiki/Q12483","display_name":"Statistics","level":1,"score":0.17275762557983398},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.16366058588027954},{"id":"https://openalex.org/C142724271","wikidata":"https://www.wikidata.org/wiki/Q7208","display_name":"Pathology","level":1,"score":0.0541607141494751},{"id":"https://openalex.org/C126322002","wikidata":"https://www.wikidata.org/wiki/Q11180","display_name":"Internal medicine","level":1,"score":0.0},{"id":"https://openalex.org/C204787440","wikidata":"https://www.wikidata.org/wiki/Q188504","display_name":"Alternative medicine","level":2,"score":0.0}],"mesh":[{"descriptor_ui":"D000553","descriptor_name":"Ambulatory Care","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D000704","descriptor_name":"Analysis of Variance","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D002138","descriptor_name":"Calibration","qualifier_ui":"Q000592","qualifier_name":"standards","is_major_topic":true},{"descriptor_ui":"D002985","descriptor_name":"Clinical Protocols","qualifier_ui":"Q000592","qualifier_name":"standards","is_major_topic":true},{"descriptor_ui":"D006801","descriptor_name":"Humans","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D012107","descriptor_name":"Research Design","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D014065","descriptor_name":"Tonometry, Ocular","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D014065","descriptor_name":"Tonometry, Ocular","qualifier_ui":"Q000451","qualifier_name":"nursing","is_major_topic":false},{"descriptor_ui":"D014065","descriptor_name":"Tonometry, Ocular","qualifier_ui":"Q000592","qualifier_name":"standards","is_major_topic":true},{"descriptor_ui":"D015400","descriptor_name":"Clinical Nursing Research","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D015982","descriptor_name":"Bias","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D019985","descriptor_name":"Benchmarking","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false}],"locations_count":1,"locations":[{"id":"pmid:16850707","doi":null,"is_oa":false,"landing_page_url":"https://pubmed.ncbi.nlm.nih.gov/16850707","pdf_url":null,"source":{"id":"https://openalex.org/S4306525036","display_name":"PubMed","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I1299303238","host_organization_name":"National Institutes of Health","host_organization_lineage":["https://openalex.org/I1299303238"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Nursing times","raw_type":"Journal Article"}],"best_oa_location":null,"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/3","score":0.9391000270843506,"display_name":"Good health and well-being"}],"study_designs":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":0,"referenced_works":[],"related_works":["https://openalex.org/W3118230613","https://openalex.org/W4400187120","https://openalex.org/W2170136313","https://openalex.org/W6885074491","https://openalex.org/W2039540987","https://openalex.org/W2028688511","https://openalex.org/W4235443915","https://openalex.org/W2409278966","https://openalex.org/W24863377","https://openalex.org/W2993411465"],"abstract_inverted_index":{"AIM:":[0],"To":[1],"discover":[2],"whether":[3],"a":[4,52,57,86,103],"protocol":[5,18,68,81,104],"for":[6,19],"calibration":[7,22,35,107],"can":[8],"improve":[9],"the":[10,21,67,77,80,92],"accuracy":[11],"of":[12,23,95],"intraocular":[13],"pressure":[14],"measuerements.":[15],"METHOD:":[16],"A":[17],"checking":[20],"equipment":[24,43],"was":[25,56,89],"implemented":[26],"in":[27,44,76],"an":[28],"ophthalmic":[29,46],"outpatient":[30],"department.":[31],"After":[32],"seven":[33],"months,":[34],"checks":[36],"were":[37,49],"compared":[38],"with":[39,82],"those":[40],"done":[41],"on":[42],"other":[45,84],"areas":[47,64],"that":[48],"not":[50,65],"following":[51,66],"protocol.":[53],"RESULTS:":[54],"There":[55],"statistically":[58],"significant":[59,87],"association":[60],"between":[61],"errors":[62,74],"and":[63],"(p":[69,98],"=":[70,99],"0.02).":[71],"In":[72],"comparing":[73],"found":[75],"area":[78],"using":[79],"all":[83],"areas,":[85],"difference":[88],"evident":[90],"at":[91],"test":[93],"point":[94],"20":[96],"mmHg":[97],"0.003).":[100],"CONCLUSION:":[101],"Using":[102],"significantly":[105],"reduces":[106],"errors.":[108]},"counts_by_year":[{"year":2013,"cited_by_count":1}],"updated_date":"2026-11-04T10:54:05.112534","created_date":"2016-06-24T00:00:00"}
