{"id":"https://openalex.org/W2406324341","doi":"https://doi.org/10.5220/0003293704440447","title":"DOUBLE HEADED PROBE FOR LOCAL PULSE WAVE VELOCITY ESTIMATION - A New Device for Hemodynamic Parameters Assessment","display_name":"DOUBLE HEADED PROBE FOR LOCAL PULSE WAVE VELOCITY ESTIMATION - A New Device for Hemodynamic Parameters Assessment","publication_year":2011,"publication_date":"2011-01-01","ids":{"openalex":"https://openalex.org/W2406324341","doi":"https://doi.org/10.5220/0003293704440447","mag":"2406324341"},"language":"en","primary_location":{"id":"doi:10.5220/0003293704440447","doi":"https://doi.org/10.5220/0003293704440447","is_oa":true,"landing_page_url":"https://doi.org/10.5220/0003293704440447","pdf_url":null,"source":{"id":"https://openalex.org/S4306419173","display_name":"International Conference on Biomedical Electronics and Devices","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":"cc-by-nc-nd","license_id":"https://openalex.org/licenses/cc-by-nc-nd","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Proceedings of the International Conference on Biomedical Electronics and Devices","raw_type":"proceedings-article"},"volume":null,"type":"conference-paper","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":true,"oa_status":"hybrid","oa_url":"https://doi.org/10.5220/0003293704440447","any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5008334880","display_name":"Helena Catarina Pereira","orcid":"https://orcid.org/0000-0002-1423-3038","observed_orcids":["https://orcid.org/0000-0002-1423-3038"]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"H. C. Pereira","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"middle","author":{"id":"https://openalex.org/A5101707978","display_name":"Jos\u00e9 Bas\u00edlio Sim\u00f5es","orcid":"https://orcid.org/0000-0002-3058-6888","observed_orcids":["https://orcid.org/0000-0002-3058-6888"]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"J. B. Simoes","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"middle","author":{"id":"https://openalex.org/A5030666993","display_name":"J.L. Malaquias","orcid":"https://orcid.org/0000-0002-6593-3077","observed_orcids":["https://orcid.org/0000-0002-6593-3077"]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"J. L. Malaquias","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"middle","author":{"id":"https://openalex.org/A5001437567","display_name":"T\u00e2nia Pereira","orcid":"https://orcid.org/0000-0003-1681-2436","observed_orcids":["https://orcid.org/0000-0003-1681-2436"]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"T. Pereira","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"middle","author":{"id":"https://openalex.org/A5082809192","display_name":"V\u00e2nia Almeida","orcid":"https://orcid.org/0000-0002-2185-7850","observed_orcids":["https://orcid.org/0000-0002-2185-7850"]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"V. Almeida","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"middle","author":{"id":"https://openalex.org/A5025709499","display_name":"E. Borges","orcid":"https://orcid.org/0009-0006-4566-3360","observed_orcids":["https://orcid.org/0009-0006-4566-3360"]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"E. Borges","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"middle","author":{"id":"https://openalex.org/A5064647118","display_name":"J. M. R. Cardoso","orcid":"https://orcid.org/0000-0002-8832-8208","observed_orcids":["https://orcid.org/0000-0002-8832-8208"]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"J. Cardoso","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"last","author":{"id":"https://openalex.org/A5086979952","display_name":"Carlos M. B. A. Correia","orcid":"https://orcid.org/0000-0002-0527-3206","observed_orcids":["https://orcid.org/0000-0002-0527-3206"]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"C. Correia","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]}],"institutions":[],"countries_distinct_count":0,"institutions_distinct_count":0,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":2.4089,"has_fulltext":false,"cited_by_count":3,"citation_normalized_percentile":{"value":0.88362069,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":88,"max":93},"biblio":{"volume":null,"issue":null,"first_page":"444","last_page":"447"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10924","display_name":"Cardiovascular Health and Disease Prevention","score":0.9047999978065491,"subfield":{"id":"https://openalex.org/subfields/2705","display_name":"Cardiology and Cardiovascular Medicine"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},"topics":[{"id":"https://openalex.org/T10924","display_name":"Cardiovascular Health and Disease Prevention","score":0.9047999978065491,"subfield":{"id":"https://openalex.org/subfields/2705","display_name":"Cardiology and Cardiovascular Medicine"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},{"id":"https://openalex.org/T11196","display_name":"Non-Invasive Vital Sign Monitoring","score":0.0917000025510788,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11700","display_name":"Hemodynamic Monitoring and Therapy","score":0.0010000000474974513,"subfield":{"id":"https://openalex.org/subfields/2746","display_name":"Surgery"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/pulse-wave-velocity","display_name":"pulse wave velocity","score":0.9649999737739563},{"id":"https://openalex.org/keywords/piezoelectric-sensors","display_name":"piezoelectric sensors","score":0.8029999732971191},{"id":"https://openalex.org/keywords/time-delay-estimation","display_name":"time delay estimation","score":0.8510000109672546},{"id":"https://openalex.org/keywords/impulse-response","display_name":"impulse response","score":0.8679999709129333},{"id":"https://openalex.org/keywords/deconvolution","display_name":"deconvolution","score":0.9800000190734863},{"id":"https://openalex.org/keywords/hemodynamic-parameters","display_name":"hemodynamic parameters","score":0.7590000033378601},{"id":"https://openalex.org/keywords/arterial-stiffness","display_name":"arterial stiffness","score":0.6940000057220459},{"id":"https://openalex.org/keywords/temporal-resolution","display_name":"temporal resolution","score":0.578000009059906},{"id":"https://openalex.org/keywords/pressure-sensors","display_name":"pressure sensors","score":0.4860000014305115}],"concepts":[{"id":"https://openalex.org/C174576160","wikidata":"https://www.wikidata.org/wiki/Q1183700","display_name":"Deconvolution","level":2,"score":0.7854475975036621},{"id":"https://openalex.org/C2778319312","wikidata":"https://www.wikidata.org/wiki/Q2118022","display_name":"Pulse wave velocity","level":3,"score":0.6137914657592773},{"id":"https://openalex.org/C70836080","wikidata":"https://www.wikidata.org/wiki/Q837940","display_name":"Impulse (physics)","level":2,"score":0.6040148735046387},{"id":"https://openalex.org/C72279823","wikidata":"https://www.wikidata.org/wiki/Q1139726","display_name":"Impulse response","level":2,"score":0.5355237722396851},{"id":"https://openalex.org/C172321821","wikidata":"https://www.wikidata.org/wiki/Q7259685","display_name":"Pulse wave","level":3,"score":0.5038136839866638},{"id":"https://openalex.org/C24890656","wikidata":"https://www.wikidata.org/wiki/Q82811","display_name":"Acoustics","level":1,"score":0.5012714862823486},{"id":"https://openalex.org/C2780009758","wikidata":"https://www.wikidata.org/wiki/Q6804172","display_name":"Measure (data warehouse)","level":2,"score":0.4416612386703491},{"id":"https://openalex.org/C2780167933","wikidata":"https://www.wikidata.org/wiki/Q1550652","display_name":"Pulse (music)","level":3,"score":0.4312487244606018},{"id":"https://openalex.org/C197424946","wikidata":"https://www.wikidata.org/wiki/Q1165717","display_name":"Waveform","level":3,"score":0.43076273798942566},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.38004326820373535},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.3658928871154785},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.3129996657371521},{"id":"https://openalex.org/C120665830","wikidata":"https://www.wikidata.org/wiki/Q14620","display_name":"Optics","level":1,"score":0.25957173109054565},{"id":"https://openalex.org/C76155785","wikidata":"https://www.wikidata.org/wiki/Q418","display_name":"Telecommunications","level":1,"score":0.18662604689598083},{"id":"https://openalex.org/C134306372","wikidata":"https://www.wikidata.org/wiki/Q7754","display_name":"Mathematical analysis","level":1,"score":0.1443057656288147},{"id":"https://openalex.org/C554190296","wikidata":"https://www.wikidata.org/wiki/Q47528","display_name":"Radar","level":2,"score":0.10023412108421326},{"id":"https://openalex.org/C84393581","wikidata":"https://www.wikidata.org/wiki/Q82642","display_name":"Blood pressure","level":2,"score":0.07893738150596619},{"id":"https://openalex.org/C94915269","wikidata":"https://www.wikidata.org/wiki/Q1834857","display_name":"Detector","level":2,"score":0.0},{"id":"https://openalex.org/C520434653","wikidata":"https://www.wikidata.org/wiki/Q38867","display_name":"Laser","level":2,"score":0.0},{"id":"https://openalex.org/C126838900","wikidata":"https://www.wikidata.org/wiki/Q77604","display_name":"Radiology","level":1,"score":0.0},{"id":"https://openalex.org/C77088390","wikidata":"https://www.wikidata.org/wiki/Q8513","display_name":"Database","level":1,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C71924100","wikidata":"https://www.wikidata.org/wiki/Q11190","display_name":"Medicine","level":0,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.5220/0003293704440447","doi":"https://doi.org/10.5220/0003293704440447","is_oa":true,"landing_page_url":"https://doi.org/10.5220/0003293704440447","pdf_url":null,"source":{"id":"https://openalex.org/S4306419173","display_name":"International Conference on Biomedical Electronics and Devices","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":"cc-by-nc-nd","license_id":"https://openalex.org/licenses/cc-by-nc-nd","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Proceedings of the International Conference on Biomedical Electronics and Devices","raw_type":"proceedings-article"}],"best_oa_location":{"id":"doi:10.5220/0003293704440447","doi":"https://doi.org/10.5220/0003293704440447","is_oa":true,"landing_page_url":"https://doi.org/10.5220/0003293704440447","pdf_url":null,"source":{"id":"https://openalex.org/S4306419173","display_name":"International Conference on Biomedical Electronics and Devices","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":"cc-by-nc-nd","license_id":"https://openalex.org/licenses/cc-by-nc-nd","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Proceedings of the International Conference on Biomedical Electronics and Devices","raw_type":"proceedings-article"},"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/3","display_name":"Good health and well-being","score":0.4043000042438507}],"study_designs":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":4,"referenced_works":["https://openalex.org/W1965097094","https://openalex.org/W1996732147","https://openalex.org/W2004223752","https://openalex.org/W2138209376"],"related_works":["https://openalex.org/W1996732147","https://openalex.org/W2024281802","https://openalex.org/W2736855906","https://openalex.org/W2736466795","https://openalex.org/W2795263500","https://openalex.org/W3005757645","https://openalex.org/W4383745199","https://openalex.org/W2646700948","https://openalex.org/W2392063625","https://openalex.org/W2899455508"],"abstract_inverted_index":{"The":[0,50],"present":[1],"work":[2],"proposes":[3],"a":[4,19,57,99],"new":[5],"device":[6],"for":[7,77],"local":[8],"pulse":[9],"wave":[10],"velocity":[11],"(PWV),":[12],"by":[13,44],"using":[14],"an":[15,144],"innovative":[16],"configuration":[17],"of":[18,36,101,115,123,133],"double":[20,51],"piezoelectric":[21],"(PZ)":[22],"sensor":[23,80],"probe.":[24],"PWV":[25,136],"is":[26,54,81,96],"assessed":[27],"in":[28,56,127],"one":[29],"single":[30],"location":[31],"and":[32,83,105,130],"involves":[33],"the":[34,40,70,73,86,90,108,113,121,124,131,141],"determination":[35],"time":[37,94,102],"delay,":[38],"between":[39],"signals":[41,114],"acquired":[42],"simultaneously":[43],"two":[45,63,116],"PZs,":[46],"23":[47],"mm":[48],"apart.":[49],"probe":[52],"(DP)":[53],"characterized":[55],"dedicated":[58],"test":[59],"bench":[60],"system,":[61],"where":[62],"main":[64],"studies":[65],"were":[66],"carried":[67],"out.":[68],"In":[69,89],"first":[71],"one,":[72,92],"impulse":[74],"response":[75],"(IR)":[76],"each":[78],"PZ":[79],"determined":[82],"evaluated":[84],"through":[85,112,140],"deconvolution":[87,128],"method.":[88],"second":[91],"DP":[93],"resolution":[95],"estimated":[97],"from":[98],"set":[100],"delay":[103],"algorithms":[104],"compared":[106],"with":[107,143],"reference":[109],"values,":[110],"obtained":[111],"pressure":[117],"sensors.":[118],"Results":[119],"demonstrate":[120],"effectiveness":[122],"inferred":[125],"IRs":[126],"purposes":[129],"possibility":[132],"measure":[134],"higher":[135],"values":[137],"(\u2248":[138],"19m/s),":[139],"DP,":[142],"error":[145],"less":[146],"than":[147],"10%.":[148]},"counts_by_year":[{"year":2017,"cited_by_count":1},{"year":2014,"cited_by_count":1}],"updated_date":"2026-10-06T10:28:23.643775","created_date":"2016-06-24T00:00:00"}
