{"id":"https://openalex.org/W2396690325","doi":null,"title":"Wireless virtual instrument measurement of surgeons' physical and mental workloads for robotic versus manual minimally invasive surgery.","display_name":"Wireless virtual instrument measurement of surgeons' physical and mental workloads for robotic versus manual minimally invasive surgery.","publication_year":2003,"publication_date":"2003-01-01","ids":{"openalex":"https://openalex.org/W2396690325","mag":"2396690325","pmid":"https://pubmed.ncbi.nlm.nih.gov/15455916"},"language":"en","primary_location":{"id":"pmid:15455916","doi":null,"is_oa":false,"landing_page_url":"https://pubmed.ncbi.nlm.nih.gov/15455916","pdf_url":null,"source":{"id":"https://openalex.org/S4306525036","display_name":"PubMed","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I1299303238","host_organization_name":"National Institutes of Health","host_organization_lineage":["https://openalex.org/I1299303238"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Studies in health technology and informatics","raw_type":"Comparative Study"},"volume":null,"type":"article","is_traditional":true,"indexed_in":["pubmed"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5103570796","display_name":"Warren D. Smith","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I43522216","display_name":"California State University, Sacramento","ror":"https://ror.org/03e26wv14","country_code":"US","type":"education","lineage":["https://openalex.org/I43522216"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Warren D Smith","raw_affiliation_strings":["Biomedical Engineering, California State University, Sacramento, 6000 J Street, Sacramento, CA 95819-6019, USA"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Biomedical Engineering, California State University, Sacramento, 6000 J Street, Sacramento, CA 95819-6019, USA","institution_ids":["https://openalex.org/I43522216"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5011276545","display_name":"Ram\u00f3n Berguer","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Ramon Berguer","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"last","author":{"id":"https://openalex.org/A5110352925","display_name":"James C. Rosser","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"James C Rosser","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":1.0672,"has_fulltext":false,"cited_by_count":21,"citation_normalized_percentile":{"value":0.79045718,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":88,"max":96},"biblio":{"volume":"94","issue":null,"first_page":"318","last_page":"24"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10916","display_name":"Surgical Simulation and Training","score":0.5903000235557556,"subfield":{"id":"https://openalex.org/subfields/2746","display_name":"Surgery"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},"topics":[{"id":"https://openalex.org/T10916","display_name":"Surgical Simulation and Training","score":0.5903000235557556,"subfield":{"id":"https://openalex.org/subfields/2746","display_name":"Surgery"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},{"id":"https://openalex.org/T10525","display_name":"Human-Automation Interaction and Safety","score":0.18930000066757202,"subfield":{"id":"https://openalex.org/subfields/3307","display_name":"Human Factors and Ergonomics"},"field":{"id":"https://openalex.org/fields/33","display_name":"Social Sciences"},"domain":{"id":"https://openalex.org/domains/2","display_name":"Social Sciences"}},{"id":"https://openalex.org/T11687","display_name":"Teleoperation and Haptic Systems","score":0.04390000179409981,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/robotic-surgery","display_name":"robotic surgery","score":0.6629999876022339},{"id":"https://openalex.org/keywords/minimally-invasive-surgery","display_name":"minimally invasive surgery","score":0.9810000061988831},{"id":"https://openalex.org/keywords/surgical-workload","display_name":"surgical workload","score":0.9110000133514404},{"id":"https://openalex.org/keywords/mental-workload","display_name":"mental workload","score":0.734000027179718},{"id":"https://openalex.org/keywords/stress-measurement","display_name":"stress measurement","score":0.5669999718666077},{"id":"https://openalex.org/keywords/human-technology-interface","display_name":"human-technology interface","score":0.8539999723434448},{"id":"https://openalex.org/keywords/surgical-performance","display_name":"surgical performance","score":0.6449999809265137},{"id":"https://openalex.org/keywords/operating-room","display_name":"operating room","score":0.5799999833106995}],"concepts":[{"id":"https://openalex.org/C2778476105","wikidata":"https://www.wikidata.org/wiki/Q628539","display_name":"Workload","level":2,"score":0.9105582237243652},{"id":"https://openalex.org/C67953723","wikidata":"https://www.wikidata.org/wiki/Q192525","display_name":"Workstation","level":2,"score":0.8004212379455566},{"id":"https://openalex.org/C113843644","wikidata":"https://www.wikidata.org/wiki/Q901882","display_name":"Interface (matter)","level":4,"score":0.6885688304901123},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.6800269484519958},{"id":"https://openalex.org/C107457646","wikidata":"https://www.wikidata.org/wiki/Q207434","display_name":"Human\u2013computer interaction","level":1,"score":0.5235906839370728},{"id":"https://openalex.org/C103203806","wikidata":"https://www.wikidata.org/wiki/Q942348","display_name":"Robotic surgery","level":2,"score":0.5101345181465149},{"id":"https://openalex.org/C3019477240","wikidata":"https://www.wikidata.org/wiki/Q1755504","display_name":"Invasive surgery","level":2,"score":0.491250216960907},{"id":"https://openalex.org/C44154836","wikidata":"https://www.wikidata.org/wiki/Q45045","display_name":"Simulation","level":1,"score":0.3712935745716095},{"id":"https://openalex.org/C71924100","wikidata":"https://www.wikidata.org/wiki/Q11190","display_name":"Medicine","level":0,"score":0.21813979744911194},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.18726864457130432},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.18018245697021484},{"id":"https://openalex.org/C141071460","wikidata":"https://www.wikidata.org/wiki/Q40821","display_name":"Surgery","level":1,"score":0.17166611552238464},{"id":"https://openalex.org/C129307140","wikidata":"https://www.wikidata.org/wiki/Q6795880","display_name":"Maximum bubble pressure method","level":3,"score":0.0},{"id":"https://openalex.org/C157915830","wikidata":"https://www.wikidata.org/wiki/Q2928001","display_name":"Bubble","level":2,"score":0.0}],"mesh":[{"descriptor_ui":"D000078329","descriptor_name":"Workforce","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D006801","descriptor_name":"Humans","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D006804","descriptor_name":"Ergonomics","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D010820","descriptor_name":"Physicians","qualifier_ui":"Q000523","qualifier_name":"psychology","is_major_topic":true},{"descriptor_ui":"D012371","descriptor_name":"Robotics","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":true},{"descriptor_ui":"D013502","descriptor_name":"General Surgery","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D014584","descriptor_name":"User-Computer Interface","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D016526","descriptor_name":"Workload","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D019060","descriptor_name":"Minimally Invasive Surgical Procedures","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true}],"locations_count":2,"locations":[{"id":"pmid:15455916","doi":null,"is_oa":false,"landing_page_url":"https://pubmed.ncbi.nlm.nih.gov/15455916","pdf_url":null,"source":{"id":"https://openalex.org/S4306525036","display_name":"PubMed","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I1299303238","host_organization_name":"National Institutes of Health","host_organization_lineage":["https://openalex.org/I1299303238"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Studies in health technology and informatics","raw_type":"Comparative Study"},{"id":"mag:2396690325","doi":null,"is_oa":false,"landing_page_url":"https://pubmed.ncbi.nlm.nih.gov/15455916","pdf_url":null,"source":{"id":"https://openalex.org/S4306525036","display_name":"PubMed","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I1299303238","host_organization_name":"National Institutes of Health","host_organization_lineage":["https://openalex.org/I1299303238"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false,"raw_source_name":"PubMed","raw_type":null}],"best_oa_location":null,"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/3","score":0.8371999859809875,"display_name":"Good health and well-being"},{"id":"https://metadata.un.org/sdg/8","score":0.48510000109672546,"display_name":"Decent work and economic growth"}],"study_designs":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":0,"referenced_works":[],"related_works":["https://openalex.org/W2406349747","https://openalex.org/W2410471207","https://openalex.org/W4407814719","https://openalex.org/W2012497014","https://openalex.org/W2086705705","https://openalex.org/W4233371040","https://openalex.org/W7099645916","https://openalex.org/W2025314169","https://openalex.org/W2089197397","https://openalex.org/W4399683719"],"abstract_inverted_index":{"The":[0,61,77,120,137],"human-technology":[1],"interface":[2,18],"in":[3,89,107],"traditional":[4],"minimally":[5],"invasive":[6],"surgery":[7,24],"(MIS)":[8],"is":[9],"difficult":[10],"for":[11,49,115,151],"the":[12,20,35,51,81,95,100,103,134,142,146,165,174],"surgeon.":[13],"Efforts":[14],"to":[15,30,110,163],"improve":[16,34],"this":[17],"include":[19],"use":[21,101],"of":[22,57,66,75,102,170],"robotic":[23,135,143,175],"systems.":[25],"Ergonomics":[26],"studies":[27,85,160],"are":[28,161],"required":[29],"help":[31],"understand":[32],"and":[33,54,68,70,72,91,113,117,148,173],"MIS":[36,127],"user":[37,171],"interface.":[38,176],"We":[39,98],"have":[40],"developed":[41],"a":[42,108],"tetherless":[43,104],"virtual":[44],"instrument":[45],"(VI)":[46],"ergonomics":[47,105],"workstation":[48,62,78,106],"measuring":[50],"physical":[52],"workloads":[53],"stress":[55,69,149],"levels":[56,150],"surgeons":[58],"performing":[59],"MIS.":[60,119],"records":[63],"physiological":[64],"measures":[65],"workload":[67,114,147],"audio":[71],"multiple":[73],"channels":[74],"video.":[76],"frees":[79],"up":[80],"subject":[82],"so":[83],"that":[84,141],"can":[86],"be":[87],"performed":[88],"complex":[90],"realistic":[92],"settings,":[93],"including":[94],"operating":[96],"room.":[97],"illustrate":[99],"study":[109,138],"compare":[111],"performance":[112,169],"manual":[116,126],"robotically-assisted":[118],"surgeon":[121],"volunteers":[122],"were":[123],"experienced":[124],"with":[125,133],"but":[128,154],"had":[129],"no":[130],"previous":[131],"experience":[132],"system.":[136],"results":[139],"showed":[140],"system":[144],"reduced":[145],"these":[152],"subjects":[153],"somewhat":[155],"degraded":[156],"their":[157],"performance.":[158],"Additional":[159],"needed":[162],"determine":[164],"relative":[166],"effects":[167],"on":[168],"inexperience":[172]},"counts_by_year":[{"year":2022,"cited_by_count":2},{"year":2019,"cited_by_count":2},{"year":2017,"cited_by_count":2},{"year":2015,"cited_by_count":1},{"year":2013,"cited_by_count":2},{"year":2012,"cited_by_count":1}],"updated_date":"2026-10-31T12:09:11.096373","created_date":"2016-06-24T00:00:00"}
