{"id":"https://openalex.org/W2393843166","doi":null,"title":"Soft Start Control of High Voltage Induction Motor Based on PLC","display_name":"Soft Start Control of High Voltage Induction Motor Based on PLC","publication_year":2010,"publication_date":"2010-01-01","ids":{"openalex":"https://openalex.org/W2393843166","mag":"2393843166"},"language":"en","primary_location":{"id":"mag:2393843166","doi":null,"is_oa":false,"landing_page_url":"http://en.cnki.com.cn/Article_en/CJFDTOTAL-ZDHT201011028.htm","pdf_url":null,"source":{"id":"https://openalex.org/S2764449953","display_name":"Automation Application","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"journal"},"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false,"raw_source_name":"Automation Application","raw_type":null},"volume":null,"type":"article","indexed_in":[],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5008110714","display_name":"Hai Xiao","orcid":"https://orcid.org/0000-0003-1460-6241","observed_orcids":["https://orcid.org/0000-0003-1460-6241","https://orcid.org/0000-0001-7010-4102","https://orcid.org/0000-0001-9399-1584"]},"institutions":[],"countries":[],"is_corresponding":true,"raw_author_name":"Hai Xiao","raw_affiliation_strings":["Sichuan Meifeng Chemical Industry Co"],"raw_orcid":"https://orcid.org/0000-0003-1460-6241","affiliations":[{"raw_affiliation_string":"Sichuan Meifeng Chemical Industry Co","institution_ids":[]}]}],"institutions":[],"countries_distinct_count":0,"institutions_distinct_count":0,"corresponding_author_ids":["https://openalex.org/A5008110714"],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":{"value":0.41306709,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":null,"last_page":null},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T13093","display_name":"Electric Power Systems and Control","score":0.5684000253677368,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T13093","display_name":"Electric Power Systems and Control","score":0.5684000253677368,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T13344","display_name":"Industrial Automation and Control Systems","score":0.4113999903202057,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10504","display_name":"Sensorless Control of Electric Motors","score":0.00800000037997961,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/soft-start","display_name":"soft start","score":0.7879999876022339},{"id":"https://openalex.org/keywords/high-voltage-induction-motor","display_name":"high-voltage induction motor","score":0.9779999852180481},{"id":"https://openalex.org/keywords/reduced-voltage-starting","display_name":"reduced voltage starting","score":0.968999981880188},{"id":"https://openalex.org/keywords/liquid-resistance","display_name":"liquid resistance","score":0.4390000104904175},{"id":"https://openalex.org/keywords/plc-control","display_name":"PLC control","score":0.6710000038146973},{"id":"https://openalex.org/keywords/siemens-s7-200-plc","display_name":"Siemens S7-200 PLC","score":0.9430000185966492},{"id":"https://openalex.org/keywords/stator-winding","display_name":"stator winding","score":0.7570000290870667},{"id":"https://openalex.org/keywords/voltage-drop","display_name":"voltage drop","score":0.7229999899864197}],"concepts":[{"id":"https://openalex.org/C80962145","wikidata":"https://www.wikidata.org/wiki/Q207450","display_name":"Induction motor","level":3,"score":0.6718760132789612},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.6419216394424438},{"id":"https://openalex.org/C135248900","wikidata":"https://www.wikidata.org/wiki/Q2666306","display_name":"Motor soft starter","level":3,"score":0.6012799143791199},{"id":"https://openalex.org/C82178898","wikidata":"https://www.wikidata.org/wiki/Q166839","display_name":"Voltage drop","level":3,"score":0.5859246253967285},{"id":"https://openalex.org/C2776529397","wikidata":"https://www.wikidata.org/wiki/Q190312","display_name":"Stator","level":2,"score":0.5749838352203369},{"id":"https://openalex.org/C100053769","wikidata":"https://www.wikidata.org/wiki/Q169893","display_name":"Siemens","level":2,"score":0.5350203514099121},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.4647507071495056},{"id":"https://openalex.org/C14485415","wikidata":"https://www.wikidata.org/wiki/Q5384730","display_name":"Equivalent series resistance","level":3,"score":0.4426397979259491},{"id":"https://openalex.org/C88182573","wikidata":"https://www.wikidata.org/wiki/Q1139740","display_name":"High voltage","level":3,"score":0.4150301218032837},{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.4149578809738159},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.39941123127937317},{"id":"https://openalex.org/C171146098","wikidata":"https://www.wikidata.org/wiki/Q124192","display_name":"Automotive engineering","level":1,"score":0.36477845907211304},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.3159472346305847},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.1950872838497162},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"mag:2393843166","doi":null,"is_oa":false,"landing_page_url":"http://en.cnki.com.cn/Article_en/CJFDTOTAL-ZDHT201011028.htm","pdf_url":null,"source":{"id":"https://openalex.org/S2764449953","display_name":"Automation Application","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"journal"},"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false,"raw_source_name":"Automation Application","raw_type":null}],"best_oa_location":null,"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/9","score":0.5378999710083008,"display_name":"Industry, innovation and infrastructure"}],"study_designs":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":0,"referenced_works":[],"related_works":["https://openalex.org/W2358298112","https://openalex.org/W2394440129","https://openalex.org/W2353546495","https://openalex.org/W2360181031","https://openalex.org/W2390445848","https://openalex.org/W968087071","https://openalex.org/W2355925791","https://openalex.org/W2062255492","https://openalex.org/W2363910917","https://openalex.org/W1974838857"],"abstract_inverted_index":{"A":[0],"reduced":[1],"voltage":[2,7,56],"starting":[3,51],"method":[4],"of":[5,49],"high":[6],"induction":[8],"motor":[9],"is":[10,16,32],"introduced.Siemens":[11],"S7-200":[12],"CN":[13],"series":[14,26],"PLC":[15],"used":[17],"as":[18],"the":[19,29,35],"control":[20],"device.The":[21],"liquid":[22,38],"resistances":[23,39],"which":[24],"are":[25,40,58],"connected":[27],"to":[28],"stator":[30],"winding":[31],"regulated":[33],"when":[34],"machine":[36],"start.The":[37,47],"short":[41],"circuit":[42],"through":[43],"star":[44],"cabinet":[45],"after":[46],"purposes":[48],"low":[50],"resistance":[52],"and":[53],"no":[54],"significant":[55],"drop":[57],"achieved.":[59]},"counts_by_year":[],"updated_date":"2026-09-24T07:57:37.273135","created_date":"2016-06-24T00:00:00"}
