{"id":"https://openalex.org/W2392861005","doi":null,"title":"STUDY ON WIND-INDUCED RESPONSE CONTROL OF TALL BUILDING USING BAFFLED WATER TANK","display_name":"STUDY ON WIND-INDUCED RESPONSE CONTROL OF TALL BUILDING USING BAFFLED WATER TANK","alternate_titles":[],"publication_year":2001,"publication_date":"2001-01-01","ids":{"openalex":"https://openalex.org/W2392861005","mag":"2392861005"},"language":"en","primary_location":{"id":"mag:2392861005","doi":null,"is_oa":false,"landing_page_url":"https://oversea.cnki.net/kcms/detail/detail.aspx?dbcode=CJFD&filename=ZSZK200104003","pdf_url":null,"source":{"id":"https://openalex.org/S2764655765","display_name":"Noise and Vibration Control","issn_l":"1006-1355","issn":["1006-1355"],"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/P4310319815","host_organization_name":"World Scientific","host_organization_lineage":["https://openalex.org/P4310319815"],"host_organization_lineage_names":["World Scientific"],"type":"journal"},"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false,"raw_source_name":"Noise and Vibration Control","raw_type":null},"parent_works":[],"lineage":["https://openalex.org/W2392861005"],"child_works_count":0,"type":"article","is_traditional":true,"indexed_in":[],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5017720328","display_name":"Liang Bo","orcid":"https://orcid.org/0000-0001-7226-8178","observed_orcids":["https://orcid.org/0000-0001-7226-8178"]},"institutions":[],"countries":[],"is_corresponding":true,"contributor_roles":[],"raw_author_name":"Liang Bo","raw_affiliation_strings":["HE Hua  TANG Jia  xiang"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"HE Hua  TANG Jia  xiang","institution_ids":[]}]}],"institutions":[],"countries_distinct_count":0,"institutions_distinct_count":0,"corresponding_author_ids":["https://openalex.org/A5017720328"],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":0,"reviewed_by_count":0,"citation_normalized_percentile":{"value":0.0,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":null,"last_page":null},"is_retracted":false,"is_pulled":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10690","display_name":"Vibration Control and Rheological Fluids","score":0.5928000211715698,"subfield":{"id":"https://openalex.org/subfields/2205","display_name":"Civil and Structural Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10690","display_name":"Vibration Control and Rheological Fluids","score":0.5928000211715698,"subfield":{"id":"https://openalex.org/subfields/2205","display_name":"Civil and Structural Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T13852","display_name":"Seismic and Structural Analysis of Tall Buildings","score":0.3540000021457672,"subfield":{"id":"https://openalex.org/subfields/2205","display_name":"Civil and Structural Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12487","display_name":"Structural Engineering and Vibration Analysis","score":0.005499999970197678,"subfield":{"id":"https://openalex.org/subfields/2205","display_name":"Civil and Structural Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/tuned-liquid-damper","display_name":"tuned liquid damper","score":0.8820000290870667},{"id":"https://openalex.org/keywords/high-rise-buildings","display_name":"high-rise buildings","score":0.7379999756813049},{"id":"https://openalex.org/keywords/wind-induced-response","display_name":"wind-induced response","score":0.8360000252723694},{"id":"https://openalex.org/keywords/wind-loads","display_name":"wind loads","score":0.6060000061988831},{"id":"https://openalex.org/keywords/time-domain-simulation","display_name":"time-domain simulation","score":0.6499999761581421},{"id":"https://openalex.org/keywords/serviceability-limit-state","display_name":"serviceability limit state","score":0.9279999732971191},{"id":"https://openalex.org/keywords/structural-vibration-control","display_name":"structural vibration control","score":0.5180000066757202}],"concepts":[{"id":"https://openalex.org/C142784634","wikidata":"https://www.wikidata.org/wiki/Q1129460","display_name":"Slosh dynamics","level":2,"score":0.8710253238677979},{"id":"https://openalex.org/C110245778","wikidata":"https://www.wikidata.org/wiki/Q2169658","display_name":"Serviceability (structure)","level":2,"score":0.8067872524261475},{"id":"https://openalex.org/C131396349","wikidata":"https://www.wikidata.org/wiki/Q913675","display_name":"Baffle","level":2,"score":0.6787413358688354},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.5582611560821533},{"id":"https://openalex.org/C199104240","wikidata":"https://www.wikidata.org/wiki/Q118291","display_name":"Marine engineering","level":1,"score":0.5444056987762451},{"id":"https://openalex.org/C66938386","wikidata":"https://www.wikidata.org/wiki/Q633538","display_name":"Structural engineering","level":1,"score":0.514809787273407},{"id":"https://openalex.org/C140096630","wikidata":"https://www.wikidata.org/wiki/Q3423628","display_name":"Damper","level":2,"score":0.5101574063301086},{"id":"https://openalex.org/C145690102","wikidata":"https://www.wikidata.org/wiki/Q2441902","display_name":"Wind engineering","level":2,"score":0.41748321056365967},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.09008312225341797}],"mesh":[],"locations_count":1,"locations":[{"id":"mag:2392861005","doi":null,"is_oa":false,"landing_page_url":"https://oversea.cnki.net/kcms/detail/detail.aspx?dbcode=CJFD&filename=ZSZK200104003","pdf_url":null,"source":{"id":"https://openalex.org/S2764655765","display_name":"Noise and Vibration Control","issn_l":"1006-1355","issn":["1006-1355"],"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/P4310319815","host_organization_name":"World Scientific","host_organization_lineage":["https://openalex.org/P4310319815"],"host_organization_lineage_names":["World Scientific"],"type":"journal"},"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false,"raw_source_name":"Noise and Vibration Control","raw_type":null}],"best_oa_location":null,"sustainable_development_goals":[{"score":0.4000000059604645,"id":"https://metadata.un.org/sdg/11","display_name":"Sustainable cities and communities"}],"study_designs":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":0,"referenced_works":[],"related_works":["https://openalex.org/W2035098756","https://openalex.org/W2409141609","https://openalex.org/W4410250779","https://openalex.org/W2492031684","https://openalex.org/W2737485301","https://openalex.org/W3205329907","https://openalex.org/W2008445771","https://openalex.org/W1561503470","https://openalex.org/W2097266577","https://openalex.org/W2052135105"],"abstract_inverted_index":{"Tuned":[0],"liquid":[1,20,37],"dampers":[2],"(TLD)installed":[3],"at":[4],"tall":[5,46,78,102],"buildings":[6],"can":[7],"suppress":[8],"dynamic":[9],"responses":[10],"of":[11,18,77,97,101],"buildings.This":[12],"paper":[13],"presents":[14],"a":[15,22,45],"new":[16],"type":[17],"tuned":[19],"damper,comprising":[21],"cylindrical":[23],"rigid":[24],"tank":[25,64,72,111],"with":[26],"anti":[27],"sloshing":[28],"baffles":[29],"fixed":[30],"to":[31,35,107],"its":[32],"inner":[33],"surface":[34],"increase":[36],"slosh":[38],"damping.The":[39],"fluctuating":[40],"wind":[41,50,53,74,98],"loads":[42],"acting":[43],"on":[44,73],"building":[47,67,79],"in":[48,56],"along":[49],"and":[51,65,93],"across":[52],"are":[54],"simulated":[55],"the":[57,62,66,70,91,109],"time":[58],"domain.The":[59],"interaction":[60],"between":[61],"water":[63,71,110],"is":[68,80],"considered,and":[69],"induced":[75,99],"response":[76],"studied.The":[81],"procedure":[82],"presented":[83],"here":[84],"provides":[85,104],"an":[86],"effective":[87],"method":[88],"for":[89],"checking":[90],"serviceability":[92],"survivability":[94],"limit":[95],"state":[96],"motion":[100],"building,and":[103],"theoretical":[105],"basis":[106],"design":[108],"rationally.":[112]},"cited_by_api_url":"https://api.openalex.org/works?filter=cites:W2392861005","counts_by_year":[],"updated_date":"2026-11-21T10:27:49.728292","created_date":"2016-06-24T00:00:00"}
