{"id":"https://openalex.org/W2388998629","doi":null,"title":"Residual Current Operated Circuit Breaker Standard Analysis","display_name":"Residual Current Operated Circuit Breaker Standard Analysis","publication_year":2007,"publication_date":"2007-01-01","ids":{"openalex":"https://openalex.org/W2388998629","mag":"2388998629"},"language":"en","primary_location":{"id":"mag:2388998629","doi":null,"is_oa":false,"landing_page_url":"http://en.cnki.com.cn/Article_en/CJFDTOTAL-JSDQ200706017.htm","pdf_url":null,"source":{"id":"https://openalex.org/S2764369300","display_name":"Jiangsu Electrical Apparatus","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"journal"},"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false,"raw_source_name":"Jiangsu Electrical Apparatus","raw_type":null},"volume":null,"type":"article","is_traditional":true,"indexed_in":[],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5034145978","display_name":"Mingchao Zhang","orcid":"https://orcid.org/0009-0002-2531-0120","observed_orcids":["https://orcid.org/0009-0002-2531-0120"]},"institutions":[],"countries":[],"is_corresponding":true,"raw_author_name":"Mingchao Zhang","raw_affiliation_strings":["Zhejiang Tianzheng Electrical Shares Co"],"raw_orcid":"https://orcid.org/0009-0002-2531-0120","affiliations":[{"raw_affiliation_string":"Zhejiang Tianzheng Electrical Shares Co","institution_ids":[]}]}],"institutions":[],"countries_distinct_count":0,"institutions_distinct_count":0,"corresponding_author_ids":["https://openalex.org/A5034145978"],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":{"value":0.0,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":null,"last_page":null},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T12737","display_name":"Electrical Fault Detection and Protection","score":0.9843999743461609,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T12737","display_name":"Electrical Fault Detection and Protection","score":0.9843999743461609,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12899","display_name":"Engineering and Technology Innovations","score":0.00419999985024333,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T13093","display_name":"Electric Power Systems and Control","score":0.000699999975040555,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/technical-requirements","display_name":"technical requirements","score":0.8240000009536743},{"id":"https://openalex.org/keywords/test-methods","display_name":"test methods","score":0.9739999771118164},{"id":"https://openalex.org/keywords/classification","display_name":"classification","score":0.5559999942779541},{"id":"https://openalex.org/keywords/electric-shock-protection","display_name":"electric shock protection","score":0.7590000033378601},{"id":"https://openalex.org/keywords/leakage-current","display_name":"leakage current","score":0.8989999890327454},{"id":"https://openalex.org/keywords/enterprise-standards","display_name":"enterprise standards","score":0.6140000224113464}],"concepts":[{"id":"https://openalex.org/C61352017","wikidata":"https://www.wikidata.org/wiki/Q211058","display_name":"Circuit breaker","level":2,"score":0.9436350464820862},{"id":"https://openalex.org/C15116251","wikidata":"https://www.wikidata.org/wiki/Q337716","display_name":"Residual-current device","level":3,"score":0.7400171160697937},{"id":"https://openalex.org/C155512373","wikidata":"https://www.wikidata.org/wiki/Q287450","display_name":"Residual","level":2,"score":0.667113184928894},{"id":"https://openalex.org/C2776099285","wikidata":"https://www.wikidata.org/wiki/Q244404","display_name":"Electric shock","level":2,"score":0.5668883919715881},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.5635147094726562},{"id":"https://openalex.org/C2909601034","wikidata":"https://www.wikidata.org/wiki/Q244404","display_name":"Electrical shock","level":2,"score":0.48041510581970215},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.4754856824874878},{"id":"https://openalex.org/C148043351","wikidata":"https://www.wikidata.org/wiki/Q4456944","display_name":"Current (fluid)","level":2,"score":0.46961861848831177},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.4471903443336487},{"id":"https://openalex.org/C66325886","wikidata":"https://www.wikidata.org/wiki/Q10860300","display_name":"Disconnector","level":3,"score":0.4165050685405731},{"id":"https://openalex.org/C171146098","wikidata":"https://www.wikidata.org/wiki/Q124192","display_name":"Automotive engineering","level":1,"score":0.40676116943359375},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.2599412202835083},{"id":"https://openalex.org/C11413529","wikidata":"https://www.wikidata.org/wiki/Q8366","display_name":"Algorithm","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"mag:2388998629","doi":null,"is_oa":false,"landing_page_url":"http://en.cnki.com.cn/Article_en/CJFDTOTAL-JSDQ200706017.htm","pdf_url":null,"source":{"id":"https://openalex.org/S2764369300","display_name":"Jiangsu Electrical Apparatus","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"journal"},"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false,"raw_source_name":"Jiangsu Electrical Apparatus","raw_type":null}],"best_oa_location":null,"sustainable_development_goals":[],"study_designs":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":0,"referenced_works":[],"related_works":["https://openalex.org/W2132534671","https://openalex.org/W4233584638","https://openalex.org/W4233591713","https://openalex.org/W4231464009","https://openalex.org/W2361018694","https://openalex.org/W2361958008","https://openalex.org/W2371174678","https://openalex.org/W2355297415","https://openalex.org/W4381487661","https://openalex.org/W2381074719"],"abstract_inverted_index":{"Because":[0],"of":[1,4,42],"electric":[2],"shock":[3],"body,":[5],"the":[6,60],"circuit":[7,20,46],"or":[8],"equipment":[9],"leakage":[10],"maybe":[11],"cause":[12],"serious":[13],"accident.":[14],"Selecting":[15],"residual":[16,43],"current":[17,44],"oper-":[18],"ated":[19],"breaker":[21],"can":[22],"avoid":[23],"accident":[24],"occurrence.":[25],"It\u2019s":[26],"necessary":[27],"to":[28,36,50,59],"study":[29],"its":[30],"product":[31,74],"standard.":[32,82],"Introduction":[33],"was":[34,57],"made":[35,58],"classification,":[37],"technical":[38],"requirements,":[39],"test":[40],"method":[41],"operated":[45],"breaker(RCCB)":[47],"with":[48],"relation":[49],"action":[51],"function":[52],"and":[53,77],"power":[54],"voltage,":[55],"analysis":[56],"articles":[61],"in":[62],"relevant":[63],"standard,":[64],"which":[65],"may":[66],"be":[67],"taken":[68],"as":[69],"references":[70],"for":[71],"making":[72],"simillar":[73],"enterprise":[75],"standard":[76],"carrying":[78],"out":[79],"rel-":[80],"evant":[81]},"counts_by_year":[],"updated_date":"2025-10-10T17:16:08.811792","created_date":"2016-06-24T00:00:00"}