{"id":"https://openalex.org/W2384771362","doi":null,"title":"Numerical Study on Flow and Heat Transfer Characteristics of Finned Tube Bundles for Air-cooled Heat Exchangers of Indirect Dry Cooling Systems in Power Plants","display_name":"Numerical Study on Flow and Heat Transfer Characteristics of Finned Tube Bundles for Air-cooled Heat Exchangers of Indirect Dry Cooling Systems in Power Plants","alternate_titles":[],"publication_year":2012,"publication_date":"2012-01-01","ids":{"openalex":"https://openalex.org/W2384771362","mag":"2384771362"},"language":"en","primary_location":{"id":"mag:2384771362","doi":null,"is_oa":false,"landing_page_url":"https://oversea.cnki.net/kcms/detail/detail.aspx?dbcode=CJFD&filename=ZGDC201232008","pdf_url":null,"source":{"id":"https://openalex.org/S4306524031","display_name":"Proceedings of the CSEE","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["cwts-core"],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"journal"},"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false,"raw_source_name":"Proceedings of the CSEE","raw_type":null},"parent_works":[],"lineage":["https://openalex.org/W2384771362"],"child_works_count":0,"pull_notice_works":[],"type":"article","is_traditional":true,"indexed_in":[],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":null,"display_name":"Lijun Yang","type":null,"orcid":null,"observed_orcids":[]},"acted_on_behalf_of":[],"institutions":[{"id":"https://openalex.org/I153473198","display_name":"North China Electric Power University","ror":"https://ror.org/04qr5t414","country_code":"CN","type":"education","lineage":["https://openalex.org/I153473198"]}],"countries":["CN"],"is_corresponding":true,"contributor_roles":[],"raw_author_name":"Lijun Yang","raw_affiliation_strings":["School of Energy Power and Mechanical Engineering,North China Electric Power University,Changping District,Beijing 102206,China)"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"School of Energy Power and Mechanical Engineering,North China Electric Power University,Changping District,Beijing 102206,China)","institution_ids":["https://openalex.org/I153473198"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":["https://openalex.org/I153473198"],"apc_list":null,"apc_paid":null,"fwci":2.2765,"has_fulltext":false,"cited_by_count":15,"reviewed_by_count":0,"citation_normalized_percentile":{"value":0.8641947,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":86,"max":97},"biblio":{"volume":null,"issue":null,"first_page":null,"last_page":null},"is_retracted":false,"is_pulled":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10998","display_name":"Heat Transfer and Optimization","score":0.9994999766349792,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10998","display_name":"Heat Transfer and Optimization","score":0.9994999766349792,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11945","display_name":"Heat Transfer Mechanisms","score":0.00019999999494757503,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12560","display_name":"Nuclear Engineering Thermal-Hydraulics","score":0.0,"subfield":{"id":"https://openalex.org/subfields/2104","display_name":"Nuclear Energy and Engineering"},"field":{"id":"https://openalex.org/fields/21","display_name":"Energy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/finned-tube-bundles","display_name":"finned tube bundles","score":0.8799999952316284},{"id":"https://openalex.org/keywords/air-cooled-heat-exchangers","display_name":"air-cooled heat exchangers","score":0.9990000128746033},{"id":"https://openalex.org/keywords/power-plants","display_name":"power plants","score":0.8539999723434448},{"id":"https://openalex.org/keywords/flow-resistance","display_name":"flow resistance","score":0.6259999871253967},{"id":"https://openalex.org/keywords/pressure-drop","display_name":"pressure drop","score":0.7739999890327454},{"id":"https://openalex.org/keywords/convection-heat-transfer-coefficient","display_name":"convection heat transfer coefficient","score":0.9369999766349792},{"id":"https://openalex.org/keywords/friction-factor","display_name":"friction factor","score":0.9430000185966492},{"id":"https://openalex.org/keywords/nusselt-number","display_name":"Nusselt number","score":0.8259999752044678}],"concepts":[{"id":"https://openalex.org/C29700514","wikidata":"https://www.wikidata.org/wiki/Q634340","display_name":"Heat transfer coefficient","level":3,"score":0.6672179698944092},{"id":"https://openalex.org/C50517652","wikidata":"https://www.wikidata.org/wiki/Q179635","display_name":"Heat transfer","level":2,"score":0.6120564937591553},{"id":"https://openalex.org/C57879066","wikidata":"https://www.wikidata.org/wiki/Q41217","display_name":"Mechanics","level":1,"score":0.6072540283203125},{"id":"https://openalex.org/C33134510","wikidata":"https://www.wikidata.org/wiki/Q5158348","display_name":"Concentric tube heat exchanger","level":4,"score":0.5993440747261047},{"id":"https://openalex.org/C97355855","wikidata":"https://www.wikidata.org/wiki/Q11473","display_name":"Thermodynamics","level":1,"score":0.5758591890335083},{"id":"https://openalex.org/C130230704","wikidata":"https://www.wikidata.org/wiki/Q898280","display_name":"Nusselt number","level":4,"score":0.5693824887275696},{"id":"https://openalex.org/C118227150","wikidata":"https://www.wikidata.org/wiki/Q6839192","display_name":"Micro heat exchanger","level":4,"score":0.5508183240890503},{"id":"https://openalex.org/C107706546","wikidata":"https://www.wikidata.org/wiki/Q189124","display_name":"Heat exchanger","level":2,"score":0.5445563793182373},{"id":"https://openalex.org/C39420092","wikidata":"https://www.wikidata.org/wiki/Q17075298","display_name":"Plate fin heat exchanger","level":4,"score":0.5255478620529175},{"id":"https://openalex.org/C114088122","wikidata":"https://www.wikidata.org/wiki/Q1261069","display_name":"Pressure drop","level":2,"score":0.5254327654838562},{"id":"https://openalex.org/C192562407","wikidata":"https://www.wikidata.org/wiki/Q228736","display_name":"Materials science","level":0,"score":0.5159869194030762},{"id":"https://openalex.org/C192866977","wikidata":"https://www.wikidata.org/wiki/Q3294462","display_name":"Dynamic scraped surface heat exchanger","level":5,"score":0.5116631984710693},{"id":"https://openalex.org/C32375409","wikidata":"https://www.wikidata.org/wiki/Q261231","display_name":"Plate heat exchanger","level":3,"score":0.4970403015613556},{"id":"https://openalex.org/C41231900","wikidata":"https://www.wikidata.org/wiki/Q918227","display_name":"Convective heat transfer","level":3,"score":0.49505415558815},{"id":"https://openalex.org/C182748727","wikidata":"https://www.wikidata.org/wiki/Q178932","display_name":"Reynolds number","level":3,"score":0.47688227891921997},{"id":"https://openalex.org/C24561367","wikidata":"https://www.wikidata.org/wiki/Q909313","display_name":"Forced convection","level":3,"score":0.45523715019226074},{"id":"https://openalex.org/C91721477","wikidata":"https://www.wikidata.org/wiki/Q778612","display_name":"Fin","level":2,"score":0.4488331973552704},{"id":"https://openalex.org/C205318045","wikidata":"https://www.wikidata.org/wiki/Q1930881","display_name":"Shell and tube heat exchanger","level":3,"score":0.4201769232749939},{"id":"https://openalex.org/C2777777821","wikidata":"https://www.wikidata.org/wiki/Q25111513","display_name":"Heat transfer enhancement","level":4,"score":0.4138903021812439},{"id":"https://openalex.org/C167131557","wikidata":"https://www.wikidata.org/wiki/Q5186725","display_name":"Critical heat flux","level":4,"score":0.3289434015750885},{"id":"https://openalex.org/C159985019","wikidata":"https://www.wikidata.org/wiki/Q181790","display_name":"Composite material","level":1,"score":0.15825629234313965},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.1283593475818634},{"id":"https://openalex.org/C196558001","wikidata":"https://www.wikidata.org/wiki/Q190132","display_name":"Turbulence","level":2,"score":0.12250003218650818}],"mesh":[],"locations_count":1,"locations":[{"id":"mag:2384771362","doi":null,"is_oa":false,"landing_page_url":"https://oversea.cnki.net/kcms/detail/detail.aspx?dbcode=CJFD&filename=ZGDC201232008","pdf_url":null,"source":{"id":"https://openalex.org/S4306524031","display_name":"Proceedings of the CSEE","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["cwts-core"],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"journal"},"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false,"raw_source_name":"Proceedings of the CSEE","raw_type":null}],"best_oa_location":null,"sustainable_development_goals":[{"score":0.75,"display_name":"Affordable and clean energy","id":"https://metadata.un.org/sdg/7"}],"study_designs":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":0,"referenced_works":[],"related_works":["https://openalex.org/W2790112216","https://openalex.org/W2384364184","https://openalex.org/W1973088653","https://openalex.org/W2094433356","https://openalex.org/W2336290971","https://openalex.org/W292421443","https://openalex.org/W2391611098","https://openalex.org/W2359965411","https://openalex.org/W2767717414","https://openalex.org/W2005929373"],"abstract_inverted_index":{"Air-cooled":[0],"heat":[1,38,45,58,74,84,118,144,156,174,207],"exchanger":[2,85],"is":[3,19,146,167,185],"one":[4],"of":[5,9,20,28,41,49,67,77,94,111,121,164,172,195,209],"the":[6,10,23,35,50,68,81,87,95,101,109,112,126,139,153,177,188,205],"main":[7],"components":[8],"indirect":[11,29,210],"dry":[12,30,211],"cooling":[13,31,78,212],"system":[14,32],"in":[15,56,152,197],"a":[16,63],"power":[17],"plant.It":[18],"benefit":[21],"to":[22,33,125,187],"optimal":[24,202],"design":[25],"and":[26,37,71,148,159,201],"operation":[27],"clarify":[34],"flow":[36,69],"transfer":[39,75,145,157,175],"characteristics":[40],"air-cooled":[42,57,206],"finned":[43,53,82,132,182,189,198],"tube":[44,54,83,133,183,199],"exchangers.The":[46],"thermo-flow":[47,127,179],"performances":[48,128],"commonly":[51],"used":[52],"bundles":[55],"exchangers":[59,208],"were":[60,90,107],"investigated":[61],"by":[62],"numerical":[64],"simulation.The":[65],"variations":[66],"resistance":[70],"average":[72],"convection":[73,117,143,155,173],"coefficient":[76,158],"air":[79],"through":[80],"with":[86],"windward":[88,140],"velocity":[89,141],"presented.The":[91],"correlating":[92],"equations":[93],"friction":[96,161],"factor":[97],"versus":[98,104],"Reynolds":[99,105],"number,and":[100],"Nusselt":[102],"number":[103,106],"fitted.On":[108],"basis":[110],"performance":[113],"evaluation":[114],"criteria":[115],"for":[116,130,204],"transfer,the":[119],"expression":[120],"Nu/f1/3":[122],"was":[123],"applied":[124],"prediction":[129],"six":[131],"bundles.The":[134],"results":[135],"show":[136],"that":[137,171],"as":[138],"increases,the":[142],"enhanced":[147],"pressure":[149,165],"drop":[150,166],"increases,resulting":[151],"increased":[154],"lowered":[160],"factor.The":[162],"increase":[163],"more":[168],"conspicuous":[169],"than":[170],"coefficient.For":[176],"integrated":[178],"performances,the":[180],"Forgo-type":[181],"bundle":[184],"superior":[186],"oval-tube":[190],"one.The":[191],"present":[192],"studies":[193],"are":[194],"use":[196],"selecting":[200],"designing":[203],"system.":[213]},"cited_by_api_url":"https://api.openalex.org/works?filter=cites:W2384771362","counts_by_year":[{"year":2026,"cited_by_count":2},{"year":2025,"cited_by_count":2},{"year":2024,"cited_by_count":2},{"year":2023,"cited_by_count":1},{"year":2020,"cited_by_count":1},{"year":2019,"cited_by_count":1},{"year":2016,"cited_by_count":1},{"year":2015,"cited_by_count":4},{"year":2014,"cited_by_count":1}],"updated_date":"2026-11-25T09:40:18.809321","created_date":"2016-06-24T00:00:00"}