{"id":"https://openalex.org/W2380241955","doi":null,"title":"Study and Development about an Intelligent Type of Monitoring and Protection Terminal Based on the Switchboard at ON-OFF Station of the Loop Network","display_name":"Study and Development about an Intelligent Type of Monitoring and Protection Terminal Based on the Switchboard at ON-OFF Station of the Loop Network","alternate_titles":[],"publication_year":2004,"publication_date":"2004-01-01","ids":{"openalex":"https://openalex.org/W2380241955","mag":"2380241955"},"language":"en","primary_location":{"id":"mag:2380241955","doi":null,"is_oa":false,"landing_page_url":"https://oversea.cnki.net/kcms/detail/detail.aspx?dbcode=CJFD&filename=GXDL200405000","pdf_url":null,"source":{"id":"https://openalex.org/S4306548506","display_name":"\u5e7f\u897f\u7535\u4e1a","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"journal"},"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false,"raw_source_name":"Guangxi Electric Power","raw_type":null},"parent_works":[],"lineage":["https://openalex.org/W2380241955"],"child_works_count":0,"pull_notice_works":[],"type":"article","is_traditional":true,"indexed_in":[],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5034764282","display_name":"Cai Shu-li","type":null,"orcid":null,"observed_orcids":[]},"acted_on_behalf_of":[],"institutions":[{"id":"https://openalex.org/I5343935","display_name":"Guilin University of Electronic Technology","ror":"https://ror.org/05arjae42","country_code":"CN","type":"education","lineage":["https://openalex.org/I5343935"]}],"countries":["CN"],"is_corresponding":true,"contributor_roles":[],"raw_author_name":"Cai Shu-li","raw_affiliation_strings":["GuiLin University of Electronic Technology,Guilin 541004,China)"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"GuiLin University of Electronic Technology,Guilin 541004,China)","institution_ids":["https://openalex.org/I5343935"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":["https://openalex.org/A5034764282"],"corresponding_institution_ids":["https://openalex.org/I5343935"],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":0,"reviewed_by_count":0,"citation_normalized_percentile":{"value":0.0,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":null,"last_page":null},"is_retracted":false,"is_pulled":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T12451","display_name":"Smart Grid and Power Systems","score":0.9916999936103821,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T12451","display_name":"Smart Grid and Power Systems","score":0.9916999936103821,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10972","display_name":"Power Systems Fault Detection","score":0.006899999920278788,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10305","display_name":"Power System Optimization and Stability","score":0.0005000000237487257,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/distribution-automation","display_name":"distribution automation","score":0.6970000267028809},{"id":"https://openalex.org/keywords/loop-networks","display_name":"loop networks","score":0.7089999914169312},{"id":"https://openalex.org/keywords/power-measurement","display_name":"power measurement","score":0.492000013589859},{"id":"https://openalex.org/keywords/power-system-protection","display_name":"power system protection","score":0.5590000152587891}],"concepts":[{"id":"https://openalex.org/C2779664074","wikidata":"https://www.wikidata.org/wiki/Q3518405","display_name":"Terminal (telecommunication)","level":2,"score":0.8008434176445007},{"id":"https://openalex.org/C2781089630","wikidata":"https://www.wikidata.org/wiki/Q21856745","display_name":"Realization (probability)","level":2,"score":0.7069445252418518},{"id":"https://openalex.org/C184670325","wikidata":"https://www.wikidata.org/wiki/Q512604","display_name":"Loop (graph theory)","level":2,"score":0.5816022753715515},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.46617674827575684},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.45322948694229126},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.38305944204330444},{"id":"https://openalex.org/C149635348","wikidata":"https://www.wikidata.org/wiki/Q193040","display_name":"Embedded system","level":1,"score":0.34840285778045654},{"id":"https://openalex.org/C76155785","wikidata":"https://www.wikidata.org/wiki/Q418","display_name":"Telecommunications","level":1,"score":0.22976437211036682},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.06561687588691711},{"id":"https://openalex.org/C105795698","wikidata":"https://www.wikidata.org/wiki/Q12483","display_name":"Statistics","level":1,"score":0.0},{"id":"https://openalex.org/C114614502","wikidata":"https://www.wikidata.org/wiki/Q76592","display_name":"Combinatorics","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"mag:2380241955","doi":null,"is_oa":false,"landing_page_url":"https://oversea.cnki.net/kcms/detail/detail.aspx?dbcode=CJFD&filename=GXDL200405000","pdf_url":null,"source":{"id":"https://openalex.org/S4306548506","display_name":"\u5e7f\u897f\u7535\u4e1a","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"journal"},"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false,"raw_source_name":"Guangxi Electric Power","raw_type":null}],"best_oa_location":null,"sustainable_development_goals":[{"score":1.0,"display_name":"Industry, innovation and infrastructure","id":"https://metadata.un.org/sdg/9"}],"study_designs":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":0,"referenced_works":[],"related_works":["https://openalex.org/W4409097542","https://openalex.org/W2982617613","https://openalex.org/W2042694396","https://openalex.org/W4381333650","https://openalex.org/W2351087559","https://openalex.org/W1891324573","https://openalex.org/W2354804069","https://openalex.org/W2357159333","https://openalex.org/W2377045444","https://openalex.org/W2386045008"],"abstract_inverted_index":{"The":[0],"Design":[1],"idea":[2],"and":[3,12,44,65],"realization":[4],"about":[5,59],"a":[6],"new":[7],"intelligent":[8],"type":[9],"of":[10,32,48,68,89],"monitoring":[11],"p":[13],"rotection":[14],"terminal":[15],"on":[16,46,82],"the":[17,30,49,56,60,72,75,90],"operating":[18,83],"switchboard":[19,84],"at":[20,85],"on-off":[21,86],"station":[22],"is":[23],"recommende":[24],"d.":[25],"In":[26],"order":[27],"to":[28],"satisty":[29],"demand":[31],"development":[33],"for":[34],"power":[35],"distribution":[36],"automati":[37],"on.":[38],"it":[39],"composes":[40],"more":[41],"practical":[42],"performances,":[43],"can,":[45],"view":[47],"whole":[50],"on-o":[51],"f":[52,53],"station,":[54],"perform":[55],"total":[57],"requirements":[58],"measurement,":[61],"protection,":[62],"mon":[63],"itoring":[64],"quality":[66],"analysis":[67],"electric":[69],"energy.":[70],"At":[71],"same":[73],"time,":[74],"particula":[76],"rities":[77],"in":[78],"field":[79],"engineering":[80],"application":[81],"stat":[87],"ion":[88],"loop":[91],"network":[92],"are":[93],"considered.":[94]},"cited_by_api_url":"https://api.openalex.org/works?filter=cites:W2380241955","counts_by_year":[],"updated_date":"2026-11-16T12:05:36.265796","created_date":"2016-06-24T00:00:00"}
