{"id":"https://openalex.org/W2377032355","doi":null,"title":"Fast unit commitment based on heuristic mixed integer programming","display_name":"Fast unit commitment based on heuristic mixed integer programming","alternate_titles":[],"publication_year":2012,"publication_date":"2012-01-01","ids":{"openalex":"https://openalex.org/W2377032355","mag":"2377032355"},"language":"en","primary_location":{"id":"mag:2377032355","doi":null,"is_oa":true,"landing_page_url":"https://oversea.cnki.net/kcms/detail/detail.aspx?dbcode=CJFD&filename=JDQW201221004","pdf_url":null,"source":{"id":"https://openalex.org/S2764567417","display_name":"Power System Protection and Control","issn_l":"1674-3415","issn":["1674-3415"],"is_oa":true,"is_in_doaj":true,"is_core":false,"listed_in":["doaj","poland-70","russia-white-list-2"],"host_organization":"https://openalex.org/P4361727523","host_organization_name":"Power System Protection and Control Press","host_organization_lineage":["https://openalex.org/P4361727523"],"host_organization_lineage_names":["Power System Protection and Control Press"],"type":"journal"},"license":"cc-by-nc","license_id":"https://openalex.org/licenses/cc-by-nc","version":null,"is_accepted":false,"is_published":false,"raw_source_name":"Power System Protection and Control","raw_type":null},"parent_works":[],"lineage":["https://openalex.org/W2377032355"],"child_works_count":0,"type":"article","is_traditional":true,"indexed_in":[],"open_access":{"is_oa":true,"oa_status":"diamond","oa_url":"https://oversea.cnki.net/kcms/detail/detail.aspx?dbcode=CJFD&filename=JDQW201221004","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5088330014","display_name":"Zhimin Ma","orcid":"https://orcid.org/0000-0002-1354-1055","observed_orcids":["https://orcid.org/0000-0002-1354-1055"]},"institutions":[],"countries":[],"is_corresponding":true,"contributor_roles":[],"raw_author_name":"Zhimin Ma","raw_affiliation_strings":["Northeast Dispatching Branch,Shenyang 110180,China)"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Northeast Dispatching Branch,Shenyang 110180,China)","institution_ids":[]}]}],"institutions":[],"countries_distinct_count":0,"institutions_distinct_count":0,"corresponding_author_ids":["https://openalex.org/A5088330014"],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":4,"citation_normalized_percentile":{"value":0.0,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":88,"max":94},"biblio":{"volume":null,"issue":null,"first_page":null,"last_page":null},"is_retracted":false,"is_pulled":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10424","display_name":"Electric Power System Optimization","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10424","display_name":"Electric Power System Optimization","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11185","display_name":"Integrated Energy Systems Optimization","score":0.0,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11941","display_name":"Power System Reliability and Maintenance","score":0.0,"subfield":{"id":"https://openalex.org/subfields/2213","display_name":"Safety, Risk, Reliability and Quality"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/unit-commitment","display_name":"unit commitment","score":0.9900000095367432},{"id":"https://openalex.org/keywords/large-scale-power-systems","display_name":"large-scale power systems","score":0.6700000166893005},{"id":"https://openalex.org/keywords/load-curve-analysis","display_name":"load curve analysis","score":0.8830000162124634},{"id":"https://openalex.org/keywords/computational-efficiency","display_name":"computational efficiency","score":0.6209999918937683}],"concepts":[{"id":"https://openalex.org/C55439883","wikidata":"https://www.wikidata.org/wiki/Q360812","display_name":"Correctness","level":2,"score":0.7090791463851929},{"id":"https://openalex.org/C56086750","wikidata":"https://www.wikidata.org/wiki/Q6042592","display_name":"Integer programming","level":2,"score":0.7069026231765747},{"id":"https://openalex.org/C126255220","wikidata":"https://www.wikidata.org/wiki/Q141495","display_name":"Mathematical optimization","level":1,"score":0.6412793397903442},{"id":"https://openalex.org/C173801870","wikidata":"https://www.wikidata.org/wiki/Q201413","display_name":"Heuristic","level":2,"score":0.5975952744483948},{"id":"https://openalex.org/C116219307","wikidata":"https://www.wikidata.org/wiki/Q7236625","display_name":"Power system simulation","level":4,"score":0.5784107446670532},{"id":"https://openalex.org/C97137487","wikidata":"https://www.wikidata.org/wiki/Q729138","display_name":"Integer (computer science)","level":2,"score":0.5724170207977295},{"id":"https://openalex.org/C2778755073","wikidata":"https://www.wikidata.org/wiki/Q10858537","display_name":"Scale (ratio)","level":2,"score":0.5269501805305481},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.5028595328330994},{"id":"https://openalex.org/C11413529","wikidata":"https://www.wikidata.org/wiki/Q8366","display_name":"Algorithm","level":1,"score":0.34945252537727356},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.3395771384239197},{"id":"https://openalex.org/C89227174","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Electric power system","level":3,"score":0.0609641969203949},{"id":"https://openalex.org/C199360897","wikidata":"https://www.wikidata.org/wiki/Q9143","display_name":"Programming language","level":1,"score":0.0},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"mag:2377032355","doi":null,"is_oa":true,"landing_page_url":"https://oversea.cnki.net/kcms/detail/detail.aspx?dbcode=CJFD&filename=JDQW201221004","pdf_url":null,"source":{"id":"https://openalex.org/S2764567417","display_name":"Power System Protection and Control","issn_l":"1674-3415","issn":["1674-3415"],"is_oa":true,"is_in_doaj":true,"is_core":false,"listed_in":["doaj","poland-70","russia-white-list-2"],"host_organization":"https://openalex.org/P4361727523","host_organization_name":"Power System Protection and Control Press","host_organization_lineage":["https://openalex.org/P4361727523"],"host_organization_lineage_names":["Power System Protection and Control Press"],"type":"journal"},"license":"cc-by-nc","license_id":"https://openalex.org/licenses/cc-by-nc","version":null,"is_accepted":false,"is_published":false,"raw_source_name":"Power System Protection and Control","raw_type":null}],"best_oa_location":{"id":"mag:2377032355","doi":null,"is_oa":true,"landing_page_url":"https://oversea.cnki.net/kcms/detail/detail.aspx?dbcode=CJFD&filename=JDQW201221004","pdf_url":null,"source":{"id":"https://openalex.org/S2764567417","display_name":"Power System Protection and Control","issn_l":"1674-3415","issn":["1674-3415"],"is_oa":true,"is_in_doaj":true,"is_core":false,"listed_in":["doaj","poland-70","russia-white-list-2"],"host_organization":"https://openalex.org/P4361727523","host_organization_name":"Power System Protection and Control Press","host_organization_lineage":["https://openalex.org/P4361727523"],"host_organization_lineage_names":["Power System Protection and Control Press"],"type":"journal"},"license":"cc-by-nc","license_id":"https://openalex.org/licenses/cc-by-nc","version":null,"is_accepted":false,"is_published":false,"raw_source_name":"Power System Protection and Control","raw_type":null},"sustainable_development_goals":[{"display_name":"Industry, innovation and infrastructure","score":0.7207000255584717,"id":"https://metadata.un.org/sdg/9"},{"display_name":"Affordable and clean energy","score":0.5690000057220459,"id":"https://metadata.un.org/sdg/7"}],"study_designs":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":0,"referenced_works":[],"related_works":["https://openalex.org/W4393172101","https://openalex.org/W1976676679","https://openalex.org/W4200476370","https://openalex.org/W2121651127","https://openalex.org/W1627374342","https://openalex.org/W2347734918","https://openalex.org/W2884397191","https://openalex.org/W3118545907","https://openalex.org/W2025183695","https://openalex.org/W2111536838"],"abstract_inverted_index":{"Single":[0],"mixed-integer":[1],"programming(MIP)":[2],"method":[3,47,58],"is":[4,59,76],"hard":[5],"to":[6,21,61],"obtain":[7],"satisfactory":[8],"solution":[9],"in":[10],"reasonable":[11],"time":[12],"when":[13],"it":[14],"solves":[15],"large-scale":[16,63],"unit":[17,32,55],"commitment":[18],"problems(UCP).In":[19],"order":[20],"solve":[22,62],"the":[23,31,38,71,91,95],"problem,we":[24],"propose":[25],"a":[26],"heuristic":[27],"MIP":[28,75],"method.Based":[29],"on":[30,44,78],"on/off":[33],"inherent":[34],"mechanism,this":[35],"algorithm":[36],"determines":[37],"part":[39],"of":[40,51,94],"integer":[41],"variables":[42],"based":[43],"priority":[45],"list":[46],"by":[48],"comprehensive":[49],"analysis":[50],"load":[52],"curve":[53],"and":[54,69,80,83],"on-off":[56],"characteristics.MIP":[57],"combined":[60],"UCP,which":[64],"can":[65],"expand":[66],"calculation":[67,72],"scale":[68],"accelerate":[70],"speed.The":[73],"improved":[74],"tested":[77],"standard":[79],"actual":[81],"system":[82],"compared":[84],"with":[85],"existing":[86],"reference.The":[87],"comparison":[88],"results":[89],"prove":[90],"correctness,validity,and":[92],"practicability":[93],"proposed":[96],"algorithm.":[97]},"cited_by_api_url":"https://api.openalex.org/works?filter=cites:W2377032355","counts_by_year":[{"year":2025,"cited_by_count":1},{"year":2023,"cited_by_count":1},{"year":2019,"cited_by_count":1},{"year":2017,"cited_by_count":1}],"updated_date":"2026-11-21T10:27:49.728292","created_date":"2016-06-24T00:00:00"}
