{"id":"https://openalex.org/W2376940253","doi":null,"title":"Characteristics and Comparison of Large-scale Electric Energy Storage Technologies","display_name":"Characteristics and Comparison of Large-scale Electric Energy Storage Technologies","publication_year":2011,"publication_date":"2011-01-01","ids":{"openalex":"https://openalex.org/W2376940253","mag":"2376940253"},"language":"en","primary_location":{"id":"mag:2376940253","doi":null,"is_oa":false,"landing_page_url":"https://en.cnki.com.cn/Article_en/CJFDTOTAL-ZJDL201112003.htm","pdf_url":null,"source":{"id":"https://openalex.org/S2764369087","display_name":"Zhejiang Electric Power","issn_l":"1007-1881","issn":["1007-1881"],"is_oa":false,"is_in_doaj":true,"is_core":false,"listed_in":["doaj"],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"journal"},"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false,"raw_source_name":"Zhejiang Electric Power","raw_type":null},"volume":null,"type":"article","is_traditional":true,"indexed_in":[],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5070659888","display_name":"Chen Liang-jin","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":true,"raw_author_name":"Chen Liang-jin","raw_affiliation_strings":["Zhejiang Electric Power Test and Research Institute,Hangzhou 310014,China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Zhejiang Electric Power Test and Research Institute,Hangzhou 310014,China","institution_ids":[]}]}],"institutions":[],"countries_distinct_count":0,"institutions_distinct_count":0,"corresponding_author_ids":["https://openalex.org/A5070659888"],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":3,"citation_normalized_percentile":{"value":0.50508475,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":87,"max":93},"biblio":{"volume":null,"issue":null,"first_page":null,"last_page":null},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T14444","display_name":"Power Systems and Renewable Energy","score":0.9994999766349792,"subfield":{"id":"https://openalex.org/subfields/2102","display_name":"Energy Engineering and Power Technology"},"field":{"id":"https://openalex.org/fields/21","display_name":"Energy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T14444","display_name":"Power Systems and Renewable Energy","score":0.9994999766349792,"subfield":{"id":"https://openalex.org/subfields/2102","display_name":"Energy Engineering and Power Technology"},"field":{"id":"https://openalex.org/fields/21","display_name":"Energy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11185","display_name":"Integrated Energy Systems Optimization","score":0.00019999999494757503,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10424","display_name":"Electric Power System Optimization","score":9.999999747378752e-05,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/electric-energy-storage","display_name":"electric energy storage","score":0.7889999747276306},{"id":"https://openalex.org/keywords/pumped-hydro-storage","display_name":"pumped storage","score":0.9419999718666077},{"id":"https://openalex.org/keywords/compressed-air-energy-storage","display_name":"compressed air energy storage","score":0.996999979019165},{"id":"https://openalex.org/keywords/flywheel-energy-storage","display_name":"flywheel energy storage","score":0.9980000257492065},{"id":"https://openalex.org/keywords/superconducting-magnetic-energy-storage","display_name":"superconducting magnetic energy storage","score":0.9279999732971191},{"id":"https://openalex.org/keywords/supercapacitors","display_name":"supercapacitors","score":0.9980000257492065},{"id":"https://openalex.org/keywords/rechargeable-batteries","display_name":"rechargeable batteries","score":0.9900000095367432},{"id":"https://openalex.org/keywords/redox-flow-batteries","display_name":"redox flow batteries","score":0.9990000128746033},{"id":"https://openalex.org/keywords/sodium-sulfur-batteries","display_name":"sodium-sulfur batteries","score":0.9419999718666077},{"id":"https://openalex.org/keywords/large-scale-energy-storage","display_name":"large-scale energy storage","score":0.6510000228881836}],"concepts":[{"id":"https://openalex.org/C73916439","wikidata":"https://www.wikidata.org/wiki/Q837718","display_name":"Energy storage","level":3,"score":0.8370774984359741},{"id":"https://openalex.org/C6585489","wikidata":"https://www.wikidata.org/wiki/Q754523","display_name":"Supercapacitor","level":4,"score":0.7083109021186829},{"id":"https://openalex.org/C2780113879","wikidata":"https://www.wikidata.org/wiki/Q1260916","display_name":"Compressed air energy storage","level":4,"score":0.677760660648346},{"id":"https://openalex.org/C31107917","wikidata":"https://www.wikidata.org/wiki/Q183576","display_name":"Flywheel","level":2,"score":0.6360710263252258},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.524660587310791},{"id":"https://openalex.org/C183739832","wikidata":"https://www.wikidata.org/wiki/Q339353","display_name":"Pumped-storage hydroelectricity","level":4,"score":0.5211589336395264},{"id":"https://openalex.org/C92311004","wikidata":"https://www.wikidata.org/wiki/Q80638","display_name":"Hydroelectricity","level":2,"score":0.5042921304702759},{"id":"https://openalex.org/C21880701","wikidata":"https://www.wikidata.org/wiki/Q2144042","display_name":"Process engineering","level":1,"score":0.46035119891166687},{"id":"https://openalex.org/C194739806","wikidata":"https://www.wikidata.org/wiki/Q66221","display_name":"Computer data storage","level":2,"score":0.4271092116832733},{"id":"https://openalex.org/C40293303","wikidata":"https://www.wikidata.org/wiki/Q27137","display_name":"Electric power","level":3,"score":0.41667425632476807},{"id":"https://openalex.org/C39432304","wikidata":"https://www.wikidata.org/wiki/Q188847","display_name":"Environmental science","level":0,"score":0.3931315541267395},{"id":"https://openalex.org/C192562407","wikidata":"https://www.wikidata.org/wiki/Q228736","display_name":"Materials science","level":0,"score":0.36821112036705017},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.3393842577934265},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.3330705165863037},{"id":"https://openalex.org/C171146098","wikidata":"https://www.wikidata.org/wiki/Q124192","display_name":"Automotive engineering","level":1,"score":0.3327009379863739},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.32863104343414307},{"id":"https://openalex.org/C188573790","wikidata":"https://www.wikidata.org/wiki/Q12705","display_name":"Renewable energy","level":2,"score":0.3095075488090515},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.305458128452301},{"id":"https://openalex.org/C30066665","wikidata":"https://www.wikidata.org/wiki/Q164399","display_name":"Capacitance","level":3,"score":0.16084381937980652},{"id":"https://openalex.org/C544738498","wikidata":"https://www.wikidata.org/wiki/Q861135","display_name":"Distributed generation","level":3,"score":0.1541001796722412},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.12018898129463196},{"id":"https://openalex.org/C17525397","wikidata":"https://www.wikidata.org/wiki/Q176140","display_name":"Electrode","level":2,"score":0.09164121747016907},{"id":"https://openalex.org/C9390403","wikidata":"https://www.wikidata.org/wiki/Q3966","display_name":"Computer hardware","level":1,"score":0.06542685627937317},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"mag:2376940253","doi":null,"is_oa":false,"landing_page_url":"https://en.cnki.com.cn/Article_en/CJFDTOTAL-ZJDL201112003.htm","pdf_url":null,"source":{"id":"https://openalex.org/S2764369087","display_name":"Zhejiang Electric Power","issn_l":"1007-1881","issn":["1007-1881"],"is_oa":false,"is_in_doaj":true,"is_core":false,"listed_in":["doaj"],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"journal"},"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false,"raw_source_name":"Zhejiang Electric Power","raw_type":null}],"best_oa_location":null,"sustainable_development_goals":[{"score":1.0,"id":"https://metadata.un.org/sdg/7","display_name":"Affordable and clean energy"}],"study_designs":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":0,"referenced_works":[],"related_works":["https://openalex.org/W2017428530","https://openalex.org/W2364879244","https://openalex.org/W2095621979","https://openalex.org/W49991695","https://openalex.org/W2898752540","https://openalex.org/W3009092291","https://openalex.org/W2765537221","https://openalex.org/W3165692736","https://openalex.org/W561864213","https://openalex.org/W2114543162"],"abstract_inverted_index":{"The":[0],"classification":[1],"of":[2,18,38],"energy":[3,19],"storage":[4,20,40],"technologies":[5,21,41],"and":[6,34],"its":[7],"application":[8],"in":[9],"the":[10,16],"electric":[11],"power":[12],"system":[13],"are":[14,32,42],"introduced.And":[15],"characteristics":[17],"involving":[22],"pumped":[23],"hydroelectric":[24],"storage,compressed":[25],"air,flywheel,superconducting":[26],"magnet,supercapacitors,secondary":[27],"batteries,redox":[28],"flow":[29],"batteries,sodium-sulphur":[30],"batteries":[31],"analyzed":[33],"compared.The":[35],"applicable":[36],"fields":[37],"various":[39],"elaborated.":[43]},"counts_by_year":[{"year":2021,"cited_by_count":1},{"year":2020,"cited_by_count":1},{"year":2016,"cited_by_count":1}],"updated_date":"2026-07-28T07:46:37.118299","created_date":"2016-06-24T00:00:00"}
