{"id":"https://openalex.org/W2376320367","doi":null,"title":"Energy saving analysis of heat pump heat recovery systems in Jinan","display_name":"Energy saving analysis of heat pump heat recovery systems in Jinan","publication_year":2012,"publication_date":"2012-01-01","ids":{"openalex":"https://openalex.org/W2376320367","mag":"2376320367"},"language":"en","primary_location":{"id":"mag:2376320367","doi":null,"is_oa":false,"landing_page_url":"https://en.cnki.com.cn/Article_en/CJFDTOTAL-SDJG201202017.htm","pdf_url":null,"source":{"id":"https://openalex.org/S2764490468","display_name":"Journal of Shandong Jianzhu University","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"journal"},"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false,"raw_source_name":"Journal of Shandong Jianzhu University","raw_type":null},"volume":null,"type":"article","is_traditional":true,"indexed_in":[],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5101579522","display_name":"Yunxia Qu","orcid":"https://orcid.org/0000-0002-9254-9759","observed_orcids":["https://orcid.org/0000-0002-9254-9759"]},"institutions":[],"countries":[],"is_corresponding":true,"raw_author_name":"Yunxia Qu","raw_affiliation_strings":["2,PAN Xue-liang3,LIU De-qiang3"],"raw_orcid":"https://orcid.org/0000-0002-9254-9759","affiliations":[{"raw_affiliation_string":"2,PAN Xue-liang3,LIU De-qiang3","institution_ids":[]}]}],"institutions":[],"countries_distinct_count":0,"institutions_distinct_count":0,"corresponding_author_ids":["https://openalex.org/A5101579522"],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":{"value":0.44710614,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":null,"last_page":null},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11529","display_name":"Refrigeration and Air Conditioning Technologies","score":0.9726999998092651,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11529","display_name":"Refrigeration and Air Conditioning Technologies","score":0.9726999998092651,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10121","display_name":"Building Energy and Comfort Optimization","score":0.013100000098347664,"subfield":{"id":"https://openalex.org/subfields/2215","display_name":"Building and Construction"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11774","display_name":"Adsorption and Cooling Systems","score":0.007000000216066837,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/heat-recovery-systems","display_name":"heat recovery systems","score":0.8299999833106995},{"id":"https://openalex.org/keywords/building-energy-conservation","display_name":"building energy conservation","score":0.8349999785423279},{"id":"https://openalex.org/keywords/sensible-heat-recovery","display_name":"sensible heat recovery","score":0.9089999794960022},{"id":"https://openalex.org/keywords/central-air-conditioning","display_name":"central air conditioning","score":0.6629999876022339},{"id":"https://openalex.org/keywords/exhaust-air","display_name":"exhaust air","score":0.7210000157356262},{"id":"https://openalex.org/keywords/heat-recovery-efficiency","display_name":"heat recovery efficiency","score":0.7379999756813049}],"concepts":[{"id":"https://openalex.org/C127145964","wikidata":"https://www.wikidata.org/wiki/Q2142051","display_name":"Heat recovery ventilation","level":3,"score":0.8465703725814819},{"id":"https://openalex.org/C2776461528","wikidata":"https://www.wikidata.org/wiki/Q131313","display_name":"Heat pump","level":3,"score":0.8456530570983887},{"id":"https://openalex.org/C44044945","wikidata":"https://www.wikidata.org/wiki/Q17028110","display_name":"Hybrid heat","level":4,"score":0.8206557631492615},{"id":"https://openalex.org/C141675481","wikidata":"https://www.wikidata.org/wiki/Q3588981","display_name":"Energy recovery","level":3,"score":0.6233746409416199},{"id":"https://openalex.org/C105994980","wikidata":"https://www.wikidata.org/wiki/Q15081379","display_name":"Waste heat recovery unit","level":3,"score":0.547235369682312},{"id":"https://openalex.org/C187949908","wikidata":"https://www.wikidata.org/wiki/Q2044954","display_name":"Air source heat pumps","level":4,"score":0.5211991667747498},{"id":"https://openalex.org/C184235594","wikidata":"https://www.wikidata.org/wiki/Q288706","display_name":"Waste heat","level":3,"score":0.5211743712425232},{"id":"https://openalex.org/C141713623","wikidata":"https://www.wikidata.org/wiki/Q1452596","display_name":"Heat pump and refrigeration cycle","level":4,"score":0.5159805417060852},{"id":"https://openalex.org/C39432304","wikidata":"https://www.wikidata.org/wiki/Q188847","display_name":"Environmental science","level":0,"score":0.5002331733703613},{"id":"https://openalex.org/C13119800","wikidata":"https://www.wikidata.org/wiki/Q902090","display_name":"Coefficient of performance","level":4,"score":0.4812445640563965},{"id":"https://openalex.org/C103742991","wikidata":"https://www.wikidata.org/wiki/Q173725","display_name":"Air conditioning","level":2,"score":0.4671482443809509},{"id":"https://openalex.org/C1715860","wikidata":"https://www.wikidata.org/wiki/Q2993367","display_name":"Recuperator","level":3,"score":0.4420109987258911},{"id":"https://openalex.org/C21880701","wikidata":"https://www.wikidata.org/wiki/Q2144042","display_name":"Process engineering","level":1,"score":0.43320271372795105},{"id":"https://openalex.org/C144179057","wikidata":"https://www.wikidata.org/wiki/Q7313122","display_name":"Renewable heat","level":5,"score":0.43264082074165344},{"id":"https://openalex.org/C186370098","wikidata":"https://www.wikidata.org/wiki/Q442787","display_name":"Energy (signal processing)","level":2,"score":0.38270702958106995},{"id":"https://openalex.org/C548081761","wikidata":"https://www.wikidata.org/wiki/Q180388","display_name":"Waste management","level":1,"score":0.37989047169685364},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.3364538848400116},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.26878243684768677},{"id":"https://openalex.org/C107706546","wikidata":"https://www.wikidata.org/wiki/Q189124","display_name":"Heat exchanger","level":2,"score":0.1358310878276825},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.0},{"id":"https://openalex.org/C105795698","wikidata":"https://www.wikidata.org/wiki/Q12483","display_name":"Statistics","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"mag:2376320367","doi":null,"is_oa":false,"landing_page_url":"https://en.cnki.com.cn/Article_en/CJFDTOTAL-SDJG201202017.htm","pdf_url":null,"source":{"id":"https://openalex.org/S2764490468","display_name":"Journal of Shandong Jianzhu University","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"journal"},"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false,"raw_source_name":"Journal of Shandong Jianzhu University","raw_type":null}],"best_oa_location":null,"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/13","display_name":"Climate action","score":0.821399986743927},{"id":"https://metadata.un.org/sdg/7","display_name":"Affordable and clean energy","score":0.75}],"study_designs":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":0,"referenced_works":[],"related_works":["https://openalex.org/W4210919109","https://openalex.org/W4251645697","https://openalex.org/W2379451945","https://openalex.org/W4226517270","https://openalex.org/W2593856816","https://openalex.org/W2373859454","https://openalex.org/W2247974156","https://openalex.org/W2155549331","https://openalex.org/W4221127349","https://openalex.org/W4389011187"],"abstract_inverted_index":{"Heat":[0],"recovery":[1,23,33,40,50,60,70,80,86],"technology":[2],"in":[3,62,91,93],"building":[4],"is":[5],"an":[6],"important":[7],"way":[8],"of":[9,21,29,38,56,99],"reducing":[10],"energy":[11,53],"consumption":[12],"and":[13,42,82],"this":[14],"article":[15],"probes":[16],"into":[17],"the":[18,26,35,52,77,94],"common":[19,47,78],"types":[20],"heat":[22,30,32,39,49,57,59,69,79,83,85],"system.It":[24],"describes":[25],"application":[27],"principle":[28],"pump":[31,58,84],"system,gives":[34],"evaluation":[36],"method":[37],"system":[41,61,71,87,98],"by":[43],"comparing":[44],"it":[45],"with":[46],"sensible":[48],"system,explores":[51],"saving":[54],"potential":[55],"Jinan":[63],"climate":[64],"conditions.The":[65],"results":[66],"show":[67],"that":[68],"efficiency":[72],"can":[73],"reach":[74],"3.18":[75],"when":[76],"device":[81],"are":[88],"used":[89],"jointly":[90],"winter":[92],"central":[95],"air":[96],"conditioning":[97],"large":[100],"exhaust":[101],"air.":[102]},"counts_by_year":[],"updated_date":"2025-10-10T17:16:08.811792","created_date":"2016-06-24T00:00:00"}
