{"id":"https://openalex.org/W2376216004","doi":null,"title":"Analysis on the Energy Consumption of Encapsulated Ice Storage System","display_name":"Analysis on the Energy Consumption of Encapsulated Ice Storage System","alternate_titles":[],"publication_year":2012,"publication_date":"2012-01-01","ids":{"openalex":"https://openalex.org/W2376216004","mag":"2376216004"},"language":"en","primary_location":{"id":"mag:2376216004","doi":null,"is_oa":false,"landing_page_url":"https://oversea.cnki.net/kcms/detail/detail.aspx?dbcode=CJFD&filename=ZLJS201202012","pdf_url":null,"source":{"id":"https://openalex.org/S2764472304","display_name":"Chinese Journal of Refrigeration Technology","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"journal"},"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false,"raw_source_name":"Chinese Journal of Refrigeration Technology","raw_type":null},"parent_works":[],"lineage":["https://openalex.org/W2376216004"],"child_works_count":0,"pull_notice_works":[],"type":"article","is_traditional":true,"indexed_in":[],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":null,"display_name":"Cong Ding","type":null,"orcid":null,"observed_orcids":[]},"acted_on_behalf_of":[],"institutions":[],"countries":[],"is_corresponding":true,"contributor_roles":[],"raw_author_name":"Cong Ding","raw_affiliation_strings":["2-Beijing China Machinery First Institute Engineering Design CO"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"2-Beijing China Machinery First Institute Engineering Design CO","institution_ids":[]}]}],"institutions":[],"countries_distinct_count":0,"institutions_distinct_count":0,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":0,"reviewed_by_count":0,"citation_normalized_percentile":{"value":0.0,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":null,"last_page":null},"is_retracted":false,"is_pulled":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10938","display_name":"Phase Change Materials Research","score":0.9404000043869019,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10938","display_name":"Phase Change Materials Research","score":0.9404000043869019,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11529","display_name":"Refrigeration and Air Conditioning Technologies","score":0.04349999874830246,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11774","display_name":"Adsorption and Cooling Systems","score":0.010300000198185444,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/capsule-size","display_name":"capsule size","score":0.8560000061988831},{"id":"https://openalex.org/keywords/flow-rate","display_name":"flow rate","score":0.8560000061988831},{"id":"https://openalex.org/keywords/charging-time","display_name":"charging time","score":0.9010000228881836},{"id":"https://openalex.org/keywords/chiller-coefficient-of-performance","display_name":"chiller coefficient of performance","score":0.8679999709129333},{"id":"https://openalex.org/keywords/pump-power","display_name":"pump power","score":0.9380000233650208},{"id":"https://openalex.org/keywords/optimal-design-parameters","display_name":"optimal design parameters","score":0.5139999985694885}],"concepts":[{"id":"https://openalex.org/C39432304","wikidata":"https://www.wikidata.org/wiki/Q188847","display_name":"Environmental science","level":0,"score":0.5733238458633423},{"id":"https://openalex.org/C73916439","wikidata":"https://www.wikidata.org/wiki/Q837718","display_name":"Energy storage","level":3,"score":0.5044656991958618},{"id":"https://openalex.org/C2780165032","wikidata":"https://www.wikidata.org/wiki/Q16869822","display_name":"Energy consumption","level":2,"score":0.5001819133758545},{"id":"https://openalex.org/C172120300","wikidata":"https://www.wikidata.org/wiki/Q1134348","display_name":"Volumetric flow rate","level":2,"score":0.45728984475135803},{"id":"https://openalex.org/C4638862","wikidata":"https://www.wikidata.org/wiki/Q1501558","display_name":"Chiller","level":2,"score":0.42911043763160706},{"id":"https://openalex.org/C57879066","wikidata":"https://www.wikidata.org/wiki/Q41217","display_name":"Mechanics","level":1,"score":0.39168018102645874},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.3418771028518677},{"id":"https://openalex.org/C44154836","wikidata":"https://www.wikidata.org/wiki/Q45045","display_name":"Simulation","level":1,"score":0.33883386850357056},{"id":"https://openalex.org/C97355855","wikidata":"https://www.wikidata.org/wiki/Q11473","display_name":"Thermodynamics","level":1,"score":0.28512346744537354},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.24164804816246033},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.15783116221427917},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.0842406153678894}],"mesh":[],"locations_count":1,"locations":[{"id":"mag:2376216004","doi":null,"is_oa":false,"landing_page_url":"https://oversea.cnki.net/kcms/detail/detail.aspx?dbcode=CJFD&filename=ZLJS201202012","pdf_url":null,"source":{"id":"https://openalex.org/S2764472304","display_name":"Chinese Journal of Refrigeration Technology","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"journal"},"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false,"raw_source_name":"Chinese Journal of Refrigeration Technology","raw_type":null}],"best_oa_location":null,"sustainable_development_goals":[{"display_name":"Affordable and clean energy","score":0.875,"id":"https://metadata.un.org/sdg/7"},{"display_name":"Climate action","score":0.5351999998092651,"id":"https://metadata.un.org/sdg/13"}],"study_designs":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":0,"referenced_works":[],"related_works":["https://openalex.org/W2374022748","https://openalex.org/W2561453187","https://openalex.org/W3017086855","https://openalex.org/W2906488748","https://openalex.org/W2046168725","https://openalex.org/W4395685347","https://openalex.org/W2653224029","https://openalex.org/W2201333018","https://openalex.org/W2677176039","https://openalex.org/W2211494619"],"abstract_inverted_index":{"An":[0],"encapsulated":[1],"ice":[2],"storage":[3],"system":[4,44],"model":[5,17,24],"is":[6,25],"established":[7],"in":[8,50],"this":[9],"paper.":[10],"The":[11,23],"numerical":[12],"results":[13],"calculated":[14],"by":[15,20],"the":[16,21,29,32,36,40,47],"are":[18],"validated":[19],"experiments.":[22],"used":[26],"to":[27],"investigate":[28],"effects":[30],"of":[31,43,52,56],"capsule":[33],"size":[34],"and":[35,45,58],"flow":[37],"rate":[38],"on":[39],"consumed":[41],"energy":[42],"determine":[46],"optimal":[48],"values":[49],"consideration":[51],"charging":[53],"duration,":[54],"power":[55],"pump":[57],"chiller":[59],"COP.":[60]},"cited_by_api_url":"https://api.openalex.org/works?filter=cites:W2376216004","counts_by_year":[],"updated_date":"2026-11-21T10:27:49.728292","created_date":"2016-06-24T00:00:00"}
