{"id":"https://openalex.org/W2374736337","doi":null,"title":"Influence of Flocculent Treatment on Concentration of Residual Partially-Hydrolyzed Polyacrylamide in Wastewater","display_name":"Influence of Flocculent Treatment on Concentration of Residual Partially-Hydrolyzed Polyacrylamide in Wastewater","publication_year":2010,"publication_date":"2010-01-01","ids":{"openalex":"https://openalex.org/W2374736337","mag":"2374736337"},"language":"en","primary_location":{"id":"mag:2374736337","doi":null,"is_oa":false,"landing_page_url":"http://en.cnki.com.cn/Article_en/CJFDTOTAL-HXYA201004019.htm","pdf_url":null,"source":{"id":"https://openalex.org/S2764353555","display_name":"Chemical Research","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"journal"},"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false,"raw_source_name":"Chemical Research","raw_type":null},"volume":null,"type":"article","is_traditional":true,"indexed_in":[],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5038511235","display_name":"MA Bao-xiang","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":true,"raw_author_name":"MA Bao-xiang","raw_affiliation_strings":["Daqing Petrochemical Engineering Company Ltd"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Daqing Petrochemical Engineering Company Ltd","institution_ids":[]}]}],"institutions":[],"countries_distinct_count":0,"institutions_distinct_count":0,"corresponding_author_ids":["https://openalex.org/A5038511235"],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":{"value":0.35399481,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":null,"last_page":null},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11188","display_name":"Coagulation and Flocculation Studies","score":0.9990000128746033,"subfield":{"id":"https://openalex.org/subfields/2312","display_name":"Water Science and Technology"},"field":{"id":"https://openalex.org/fields/23","display_name":"Environmental Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11188","display_name":"Coagulation and Flocculation Studies","score":0.9990000128746033,"subfield":{"id":"https://openalex.org/subfields/2312","display_name":"Water Science and Technology"},"field":{"id":"https://openalex.org/fields/23","display_name":"Environmental Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11781","display_name":"Wastewater Treatment and Reuse","score":9.999999747378752e-05,"subfield":{"id":"https://openalex.org/subfields/2311","display_name":"Waste Management and Disposal"},"field":{"id":"https://openalex.org/fields/23","display_name":"Environmental Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10491","display_name":"Enhanced Oil Recovery Techniques","score":9.999999747378752e-05,"subfield":{"id":"https://openalex.org/subfields/2103","display_name":"Fuel Technology"},"field":{"id":"https://openalex.org/fields/21","display_name":"Energy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/partially-hydrolyzed-polyacrylamide","display_name":"partially hydrolyzed polyacrylamide","score":0.9110000133514404},{"id":"https://openalex.org/keywords/flocculation","display_name":"flocculation","score":0.7400000095367432},{"id":"https://openalex.org/keywords/inorganic-flocculants","display_name":"inorganic flocculants","score":0.8640000224113464},{"id":"https://openalex.org/keywords/organic-flocculants","display_name":"organic flocculants","score":0.9819999933242798},{"id":"https://openalex.org/keywords/flocculant-dosage","display_name":"flocculant dosage","score":0.8100000023841858},{"id":"https://openalex.org/keywords/optical-transmittance","display_name":"optical transmittance","score":0.8960000276565552},{"id":"https://openalex.org/keywords/oilfield-wastewater-treatment","display_name":"oilfield wastewater treatment","score":0.625}],"concepts":[{"id":"https://openalex.org/C148815931","wikidata":"https://www.wikidata.org/wiki/Q900689","display_name":"Flocculation","level":2,"score":0.9695916771888733},{"id":"https://openalex.org/C2778862431","wikidata":"https://www.wikidata.org/wiki/Q416002","display_name":"Polyacrylamide","level":2,"score":0.9603468179702759},{"id":"https://openalex.org/C185592680","wikidata":"https://www.wikidata.org/wiki/Q2329","display_name":"Chemistry","level":0,"score":0.6969605088233948},{"id":"https://openalex.org/C94412978","wikidata":"https://www.wikidata.org/wiki/Q103135","display_name":"Hydrolysis","level":2,"score":0.6726213693618774},{"id":"https://openalex.org/C43617362","wikidata":"https://www.wikidata.org/wiki/Q170050","display_name":"Chromatography","level":1,"score":0.5747596025466919},{"id":"https://openalex.org/C94061648","wikidata":"https://www.wikidata.org/wiki/Q336191","display_name":"Wastewater","level":2,"score":0.5615209937095642},{"id":"https://openalex.org/C155512373","wikidata":"https://www.wikidata.org/wiki/Q287450","display_name":"Residual","level":2,"score":0.4718753397464752},{"id":"https://openalex.org/C521977710","wikidata":"https://www.wikidata.org/wiki/Q81163","display_name":"Polymer","level":2,"score":0.44484737515449524},{"id":"https://openalex.org/C57442070","wikidata":"https://www.wikidata.org/wiki/Q221275","display_name":"Sewage treatment","level":2,"score":0.44437310099601746},{"id":"https://openalex.org/C42360764","wikidata":"https://www.wikidata.org/wiki/Q83588","display_name":"Chemical engineering","level":1,"score":0.38291001319885254},{"id":"https://openalex.org/C87717796","wikidata":"https://www.wikidata.org/wiki/Q146326","display_name":"Environmental engineering","level":1,"score":0.22368857264518738},{"id":"https://openalex.org/C178790620","wikidata":"https://www.wikidata.org/wiki/Q11351","display_name":"Organic chemistry","level":1,"score":0.11322471499443054},{"id":"https://openalex.org/C188027245","wikidata":"https://www.wikidata.org/wiki/Q750446","display_name":"Polymer chemistry","level":1,"score":0.10867667198181152},{"id":"https://openalex.org/C39432304","wikidata":"https://www.wikidata.org/wiki/Q188847","display_name":"Environmental science","level":0,"score":0.06127998232841492},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.0},{"id":"https://openalex.org/C11413529","wikidata":"https://www.wikidata.org/wiki/Q8366","display_name":"Algorithm","level":1,"score":0.0},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"mag:2374736337","doi":null,"is_oa":false,"landing_page_url":"http://en.cnki.com.cn/Article_en/CJFDTOTAL-HXYA201004019.htm","pdf_url":null,"source":{"id":"https://openalex.org/S2764353555","display_name":"Chemical Research","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"journal"},"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false,"raw_source_name":"Chemical Research","raw_type":null}],"best_oa_location":null,"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/12","display_name":"Responsible consumption and production","score":0.807699978351593},{"id":"https://metadata.un.org/sdg/6","display_name":"Clean water and sanitation","score":0.7778000235557556}],"study_designs":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":0,"referenced_works":[],"related_works":["https://openalex.org/W2003609497","https://openalex.org/W2351462641","https://openalex.org/W2365588844","https://openalex.org/W2368255457","https://openalex.org/W2375404514","https://openalex.org/W2375039397","https://openalex.org/W2390214195","https://openalex.org/W2332295152","https://openalex.org/W2376071815","https://openalex.org/W2377566630"],"abstract_inverted_index":{"Wastewater":[0],"produced":[1],"from":[2],"polymer":[3],"flooding":[4],"was":[5],"treated":[6,40,59],"by":[7],"inorganic":[8,42,76,81],"and":[9,17,32,50],"organic":[10,61,97],"flocculants.The":[11],"variations":[12],"of":[13,20,45,56,64,72,84,100,107],"the":[14,57,73,75,105,112],"mass":[15],"concentration":[16,44,63,83,99],"light":[18,91],"transmission":[19],"residual":[21,46,65,85,101],"partially-hydrolyzed":[22],"polyacrylamide(HPAM)":[23],"in":[24,111],"supernatant":[25],"fluid":[26],"after":[27],"treatment":[28],"with":[29,41,53,60,69,80,96],"single":[30],"flocculant":[31,77],"combined":[33,79,95],"flocculants":[34],"were":[35],"investigated.Results":[36],"show":[37],"that":[38],"when":[39],"flocculant,the":[43,62,82,98],"HPAM":[47,66,86,102],"initially":[48],"decreases":[49],"then":[51],"increases":[52,68],"increasing":[54,70],"dosage":[55,71,106],"flocculant.However,when":[58],"constantly":[67],"flocculant.When":[74],"is":[78,87,94],"inversely":[88],"proportional":[89],"to":[90],"transmission.When":[92],"it":[93],"depends":[103],"on":[104],"cation":[108],"polyacrylamide(CPAM)":[109],"added":[110],"system.":[113]},"counts_by_year":[],"updated_date":"2026-08-18T07:49:30.821534","created_date":"2016-06-24T00:00:00"}
