{"id":"https://openalex.org/W2370179332","doi":null,"title":"Degradation of Toluene Under the Action of Plant","display_name":"Degradation of Toluene Under the Action of Plant","publication_year":2010,"publication_date":"2010-01-01","ids":{"openalex":"https://openalex.org/W2370179332","mag":"2370179332"},"language":"en","primary_location":{"id":"mag:2370179332","doi":null,"is_oa":false,"landing_page_url":"https://en.cnki.com.cn/Article_en/CJFDTOTAL-JYCT201003020.htm","pdf_url":null,"source":{"id":"https://openalex.org/S2765032293","display_name":"Insulating Materials","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"journal"},"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false,"raw_source_name":"Insulating Materials","raw_type":null},"volume":null,"type":"article","is_traditional":true,"indexed_in":[],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5002750889","display_name":"Juan Wang","orcid":"https://orcid.org/0000-0002-1340-9011","observed_orcids":["https://orcid.org/0000-0002-1340-9011","https://orcid.org/0009-0009-5991-1005"]},"institutions":[{"id":"https://openalex.org/I5343935","display_name":"Guilin University of Electronic Technology","ror":"https://ror.org/05arjae42","country_code":"CN","type":"education","lineage":["https://openalex.org/I5343935"]}],"countries":["CN"],"is_corresponding":true,"raw_author_name":"Juan Wang","raw_affiliation_strings":["College of Electronic Engineering Guilin University of Electronic Technology Guilin, 541004, China"],"raw_orcid":"https://orcid.org/0000-0002-1340-9011","affiliations":[{"raw_affiliation_string":"College of Electronic Engineering Guilin University of Electronic Technology Guilin, 541004, China","institution_ids":["https://openalex.org/I5343935"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":["https://openalex.org/A5002750889"],"corresponding_institution_ids":["https://openalex.org/I5343935"],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":{"value":0.30828347,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":null,"last_page":null},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11002","display_name":"Indoor Air Quality and Microbial Exposure","score":0.9301999807357788,"subfield":{"id":"https://openalex.org/subfields/2307","display_name":"Health, Toxicology and Mutagenesis"},"field":{"id":"https://openalex.org/fields/23","display_name":"Environmental Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11002","display_name":"Indoor Air Quality and Microbial Exposure","score":0.9301999807357788,"subfield":{"id":"https://openalex.org/subfields/2307","display_name":"Health, Toxicology and Mutagenesis"},"field":{"id":"https://openalex.org/fields/23","display_name":"Environmental Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11821","display_name":"Odor and Emission Control Technologies","score":0.06379999965429306,"subfield":{"id":"https://openalex.org/subfields/1508","display_name":"Process Chemistry and Technology"},"field":{"id":"https://openalex.org/fields/15","display_name":"Chemical Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10324","display_name":"Microbial bioremediation and biosurfactants","score":0.002400000113993883,"subfield":{"id":"https://openalex.org/subfields/2310","display_name":"Pollution"},"field":{"id":"https://openalex.org/fields/23","display_name":"Environmental Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/toluene-degradation","display_name":"toluene degradation","score":0.9649999737739563},{"id":"https://openalex.org/keywords/chlorophytum","display_name":"Chlorophytum","score":0.640999972820282},{"id":"https://openalex.org/keywords/ivy","display_name":"ivy","score":0.953000009059906},{"id":"https://openalex.org/keywords/phytoremediation","display_name":"phytoremediation","score":0.843999981880188},{"id":"https://openalex.org/keywords/degradation-rate","display_name":"degradation rate","score":0.8230000138282776},{"id":"https://openalex.org/keywords/volatile-organic-compounds","display_name":"volatile organic compounds","score":0.6769999861717224}],"concepts":[{"id":"https://openalex.org/C2778142098","wikidata":"https://www.wikidata.org/wiki/Q15779","display_name":"Toluene","level":2,"score":0.9837679862976074},{"id":"https://openalex.org/C2779679103","wikidata":"https://www.wikidata.org/wiki/Q5251805","display_name":"Degradation (telecommunications)","level":2,"score":0.8339115381240845},{"id":"https://openalex.org/C185592680","wikidata":"https://www.wikidata.org/wiki/Q2329","display_name":"Chemistry","level":0,"score":0.4608002007007599},{"id":"https://openalex.org/C43617362","wikidata":"https://www.wikidata.org/wiki/Q170050","display_name":"Chromatography","level":1,"score":0.4152612090110779},{"id":"https://openalex.org/C107872376","wikidata":"https://www.wikidata.org/wiki/Q321355","display_name":"Environmental chemistry","level":1,"score":0.40803995728492737},{"id":"https://openalex.org/C13965031","wikidata":"https://www.wikidata.org/wiki/Q243545","display_name":"Nuclear chemistry","level":1,"score":0.40773844718933105},{"id":"https://openalex.org/C178790620","wikidata":"https://www.wikidata.org/wiki/Q11351","display_name":"Organic chemistry","level":1,"score":0.26435279846191406},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.0},{"id":"https://openalex.org/C76155785","wikidata":"https://www.wikidata.org/wiki/Q418","display_name":"Telecommunications","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"mag:2370179332","doi":null,"is_oa":false,"landing_page_url":"https://en.cnki.com.cn/Article_en/CJFDTOTAL-JYCT201003020.htm","pdf_url":null,"source":{"id":"https://openalex.org/S2765032293","display_name":"Insulating Materials","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"journal"},"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false,"raw_source_name":"Insulating Materials","raw_type":null}],"best_oa_location":null,"sustainable_development_goals":[],"study_designs":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":0,"referenced_works":[],"related_works":["https://openalex.org/W2085659280","https://openalex.org/W2064728207","https://openalex.org/W1978763625","https://openalex.org/W2344794868","https://openalex.org/W2239346716","https://openalex.org/W7008105220","https://openalex.org/W4383535216","https://openalex.org/W2267059861","https://openalex.org/W2389639324","https://openalex.org/W2349819554"],"abstract_inverted_index":{"Chlorophytum":[0],"Phnom":[1,72],"Penh":[2,73],"and":[3,13,37,82,91],"ivy":[4],"were":[5],"used":[6],"to":[7,34],"degrade":[8,31],"various":[9],"concentration":[10],"of":[11,53,62,68,78],"toluene":[12,16,33,46,57],"then":[14],"the":[15,26,32,38,45,48],"content":[17],"was":[18],"detected":[19],"by":[20],"gas":[21],"chromatography.The":[22],"experiments":[23],"show":[24],"that":[25,61],"two":[27],"plant":[28],"species":[29],"can":[30],"some":[35],"extent":[36],"degradation":[39,51,76],"capability":[40],"will":[41],"decrease":[42],"with":[43,70],"increasing":[44],"content.Within":[47],"same":[49,84],"period,the":[50],"rate":[52],"lower":[54],"concentration(20":[55],"mg/m3)of":[56],"is":[58],"higher":[59,63],"than":[60],"concentration(160":[64],"mg/m3).After":[65],"16":[66],"hours":[67],"reaction":[69],"chlorophytum":[71],"or":[74],"ivy,the":[75],"rates":[77],"toluene(20":[79],"mg/m3)are":[80,88],"45.6%":[81],"49.3%,respectively;however,the":[83],"values":[85],"for":[86],"toluene(160":[87],"only":[89],"28.4%":[90],"21.6%,respectively.":[92]},"counts_by_year":[],"updated_date":"2026-09-24T07:57:37.273135","created_date":"2016-06-24T00:00:00"}
