{"id":"https://openalex.org/W2362124405","doi":null,"title":"An Online Thermal Condition Monitoring System with Wireless Sensor Network Based on ZigBee Technology for Transmission Line Joints","display_name":"An Online Thermal Condition Monitoring System with Wireless Sensor Network Based on ZigBee Technology for Transmission Line Joints","publication_year":2008,"publication_date":"2008-01-01","ids":{"openalex":"https://openalex.org/W2362124405","mag":"2362124405"},"language":"en","primary_location":{"id":"mag:2362124405","doi":null,"is_oa":false,"landing_page_url":"http://en.cnki.com.cn/Article_en/CJFDTOTAL-DLXT200816017.htm","pdf_url":null,"source":{"id":"https://openalex.org/S2764498263","display_name":"Dianli xitong zidonghua","issn_l":"1000-1026","issn":["1000-1026"],"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":["poland-100","russia-white-list-1"],"host_organization":"https://openalex.org/P4322764865","host_organization_name":"State Grid Electric Power Research Institute Co., Ltd.","host_organization_lineage":["https://openalex.org/P4322764865"],"host_organization_lineage_names":["State Grid Electric Power Research Institute Co., Ltd."],"type":"journal"},"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false,"raw_source_name":"Dianli xitong zidonghua","raw_type":null},"volume":null,"type":"article","is_traditional":true,"indexed_in":[],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":null,"display_name":"Yi Xing","orcid":"https://orcid.org/0000-0001-9257-7613","observed_orcids":["https://orcid.org/0000-0001-9257-7613"]},"institutions":[{"id":"https://openalex.org/I183067930","display_name":"Shanghai Jiao Tong University","ror":"https://ror.org/0220qvk04","country_code":"CN","type":"education","lineage":["https://openalex.org/I183067930"]}],"countries":["CN"],"is_corresponding":true,"raw_author_name":"Yi Xing","raw_affiliation_strings":["Shanghai Jiaotong University, Shanghai, 200240, China"],"raw_orcid":"https://orcid.org/0000-0001-9257-7613","affiliations":[{"raw_affiliation_string":"Shanghai Jiaotong University, Shanghai, 200240, China","institution_ids":["https://openalex.org/I183067930"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":["https://openalex.org/I183067930"],"apc_list":null,"apc_paid":null,"fwci":0.5204,"has_fulltext":false,"cited_by_count":3,"citation_normalized_percentile":{"value":0.79060419,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":94},"biblio":{"volume":null,"issue":null,"first_page":null,"last_page":null},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T13535","display_name":"Wireless Sensor Networks and IoT","score":0.9868000149726868,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T13535","display_name":"Wireless Sensor Networks and IoT","score":0.9868000149726868,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T14225","display_name":"Advanced Sensor and Control Systems","score":0.011099999770522118,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12804","display_name":"Thermal Analysis in Power Transmission","score":0.0008999999845400453,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/temperature-monitoring","display_name":"temperature monitoring","score":0.8399999737739563},{"id":"https://openalex.org/keywords/online-condition-monitoring","display_name":"online condition monitoring","score":0.7609999775886536},{"id":"https://openalex.org/keywords/zigbee","display_name":"ZigBee","score":0.9559999704360962},{"id":"https://openalex.org/keywords/wireless-sensor-networks","display_name":"wireless sensor networks","score":0.9769999980926514},{"id":"https://openalex.org/keywords/self-organizing-networks","display_name":"self-organizing networks","score":0.6769999861717224},{"id":"https://openalex.org/keywords/energy-efficient-data-transmission","display_name":"energy-efficient data transmission","score":0.6959999799728394},{"id":"https://openalex.org/keywords/dynamic-topology","display_name":"dynamic topology","score":0.9179999828338623},{"id":"https://openalex.org/keywords/power-equipment-condition-monitoring","display_name":"power equipment condition monitoring","score":0.9089999794960022}],"concepts":[{"id":"https://openalex.org/C161691276","wikidata":"https://www.wikidata.org/wiki/Q7001363","display_name":"NeuRFon","level":5,"score":0.7296115756034851},{"id":"https://openalex.org/C24590314","wikidata":"https://www.wikidata.org/wiki/Q336038","display_name":"Wireless sensor network","level":2,"score":0.7024244070053101},{"id":"https://openalex.org/C555944384","wikidata":"https://www.wikidata.org/wiki/Q249","display_name":"Wireless","level":2,"score":0.542586624622345},{"id":"https://openalex.org/C199845137","wikidata":"https://www.wikidata.org/wiki/Q145490","display_name":"Network topology","level":2,"score":0.5405539274215698},{"id":"https://openalex.org/C557945733","wikidata":"https://www.wikidata.org/wiki/Q389772","display_name":"Data transmission","level":2,"score":0.5400500893592834},{"id":"https://openalex.org/C761482","wikidata":"https://www.wikidata.org/wiki/Q118093","display_name":"Transmission (telecommunications)","level":2,"score":0.5328018665313721},{"id":"https://openalex.org/C41971633","wikidata":"https://www.wikidata.org/wiki/Q6398155","display_name":"Key distribution in wireless sensor networks","level":4,"score":0.5087500214576721},{"id":"https://openalex.org/C149635348","wikidata":"https://www.wikidata.org/wiki/Q193040","display_name":"Embedded system","level":1,"score":0.4768558442592621},{"id":"https://openalex.org/C108037233","wikidata":"https://www.wikidata.org/wiki/Q11375","display_name":"Wireless network","level":3,"score":0.473289430141449},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.43326523900032043},{"id":"https://openalex.org/C31258907","wikidata":"https://www.wikidata.org/wiki/Q1301371","display_name":"Computer network","level":1,"score":0.4302327036857605},{"id":"https://openalex.org/C140311924","wikidata":"https://www.wikidata.org/wiki/Q200928","display_name":"Electric power transmission","level":2,"score":0.4243658781051636},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.40024104714393616},{"id":"https://openalex.org/C79403827","wikidata":"https://www.wikidata.org/wiki/Q3988","display_name":"Real-time computing","level":1,"score":0.36749058961868286},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.22174444794654846},{"id":"https://openalex.org/C76155785","wikidata":"https://www.wikidata.org/wiki/Q418","display_name":"Telecommunications","level":1,"score":0.1627790331840515}],"mesh":[],"locations_count":1,"locations":[{"id":"mag:2362124405","doi":null,"is_oa":false,"landing_page_url":"http://en.cnki.com.cn/Article_en/CJFDTOTAL-DLXT200816017.htm","pdf_url":null,"source":{"id":"https://openalex.org/S2764498263","display_name":"Dianli xitong zidonghua","issn_l":"1000-1026","issn":["1000-1026"],"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":["poland-100","russia-white-list-1"],"host_organization":"https://openalex.org/P4322764865","host_organization_name":"State Grid Electric Power Research Institute Co., Ltd.","host_organization_lineage":["https://openalex.org/P4322764865"],"host_organization_lineage_names":["State Grid Electric Power Research Institute Co., Ltd."],"type":"journal"},"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false,"raw_source_name":"Dianli xitong zidonghua","raw_type":null}],"best_oa_location":null,"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/9","display_name":"Industry, innovation and infrastructure","score":1.0}],"study_designs":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":0,"referenced_works":[],"related_works":["https://openalex.org/W1983258660","https://openalex.org/W2099890987","https://openalex.org/W2365885988","https://openalex.org/W2357054953","https://openalex.org/W2066513536","https://openalex.org/W7098065471","https://openalex.org/W2537593924","https://openalex.org/W2388369084","https://openalex.org/W2349221625","https://openalex.org/W2381053650"],"abstract_inverted_index":{"Based":[0],"on":[1,56],"the":[2,6,19,31,42,50,72,77],"basic":[3],"principle":[4],"of":[5,30,41,76,82],"wireless":[7,12],"sensor":[8],"network,a":[9],"new-type":[10],"ZigBee":[11,57,78],"self-network":[13],"communication":[14],"platform":[15],"is":[16,28,39,60],"applied":[17],"in":[18,80,90],"online":[20,93],"transmission":[21,89],"line":[22],"joints":[23,51],"temperature":[24,52],"monitoring":[25,53],"system.A":[26],"description":[27],"made":[29],"hardware":[32],"and":[33,36,44,65],"software":[34],"structure":[35],"an":[37],"account":[38],"given":[40],"scheme":[43],"algorithm":[45],"for":[46,49,62],"aggregated":[47],"networking":[48],"nodes":[54],"based":[55],"technology.A":[58],"method":[59],"proposed":[61],"realizing":[63],"reliable,energy-saving":[64],"highly":[66],"efficient":[67],"data":[68],"transmission.Test":[69],"results":[70],"show":[71],"unique":[73],"application":[74],"superiority":[75],"technology":[79],"terms":[81],"self-association,dynamic":[83],"network":[84,86],"topology,large":[85],"capacity,and":[87],"data-centralized":[88],"power":[91],"equipment":[92],"monitoring.":[94]},"counts_by_year":[{"year":2016,"cited_by_count":1},{"year":2012,"cited_by_count":1}],"updated_date":"2026-09-27T08:07:27.782135","created_date":"2016-06-24T00:00:00"}