{"id":"https://openalex.org/W2356536498","doi":null,"title":"Study on Transient Characteristics of Rotary Vane Compressor for Automobile Air Conditioner during Startup","display_name":"Study on Transient Characteristics of Rotary Vane Compressor for Automobile Air Conditioner during Startup","alternate_titles":[],"publication_year":2006,"publication_date":"2006-01-01","ids":{"openalex":"https://openalex.org/W2356536498","mag":"2356536498"},"language":"en","primary_location":{"id":"mag:2356536498","doi":null,"is_oa":false,"landing_page_url":"http://caod.oriprobe.com/articles/10368970/Study_on_Transient_Characteristics_of_Rotary_Vane_Compressor_for_Autom.htm","pdf_url":null,"source":{"id":"https://openalex.org/S2764631204","display_name":"Fluid Machinery","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["cwts-core"],"host_organization":"https://openalex.org/P4324114407","host_organization_name":"Airwalk Publications","host_organization_lineage":["https://openalex.org/P4324114407"],"host_organization_lineage_names":["Airwalk Publications"],"type":"journal"},"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false,"raw_source_name":"Fluid Machinery","raw_type":null},"parent_works":[],"lineage":["https://openalex.org/W2356536498"],"child_works_count":0,"pull_notice_works":[],"type":"article","is_traditional":true,"indexed_in":[],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":null,"display_name":"Yue Peng","type":null,"orcid":null,"observed_orcids":[]},"acted_on_behalf_of":[],"institutions":[{"id":"https://openalex.org/I87445476","display_name":"Xi'an Jiaotong University","ror":"https://ror.org/017zhmm22","country_code":"CN","type":"education","lineage":["https://openalex.org/I87445476"]}],"countries":["CN"],"is_corresponding":false,"contributor_roles":[],"raw_author_name":"Yue Peng","raw_affiliation_strings":["Xi\u2019an Jiaotong University, Xi\u2019an 710049, China)"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Xi\u2019an Jiaotong University, Xi\u2019an 710049, China)","institution_ids":["https://openalex.org/I87445476"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5113021681","display_name":"Pengcheng Shu","type":null,"orcid":null,"observed_orcids":[]},"acted_on_behalf_of":[],"institutions":[],"countries":[],"is_corresponding":false,"contributor_roles":[],"raw_author_name":"Pengcheng Shu","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"last","author":{"id":"https://openalex.org/A5101826194","display_name":"Liansheng Li","type":null,"orcid":"https://orcid.org/0009-0001-2430-8443","observed_orcids":["https://orcid.org/0009-0001-2430-8443"]},"acted_on_behalf_of":[],"institutions":[{"id":"https://openalex.org/I87445476","display_name":"Xi'an Jiaotong University","ror":"https://ror.org/017zhmm22","country_code":"CN","type":"education","lineage":["https://openalex.org/I87445476"]}],"countries":["CN"],"is_corresponding":false,"contributor_roles":[],"raw_author_name":"Liansheng Li","raw_affiliation_strings":["Xi\u2019an Jiaotong University, Xi\u2019an 710049, China)"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Xi\u2019an Jiaotong University, Xi\u2019an 710049, China)","institution_ids":["https://openalex.org/I87445476"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":0,"reviewed_by_count":0,"citation_normalized_percentile":{"value":0.0,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":"34","issue":"2","first_page":null,"last_page":null},"is_retracted":false,"is_pulled":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11529","display_name":"Refrigeration and Air Conditioning Technologies","score":0.9994999766349792,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11529","display_name":"Refrigeration and Air Conditioning Technologies","score":0.9994999766349792,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10944","display_name":"Turbomachinery Performance and Optimization","score":0.00019999999494757503,"subfield":{"id":"https://openalex.org/subfields/2202","display_name":"Aerospace Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12139","display_name":"Advanced Thermodynamic Systems and Engines","score":0.0,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/rotary-vane-compressor","display_name":"rotary vane compressor","score":0.9990000128746033},{"id":"https://openalex.org/keywords/automotive-air-conditioning","display_name":"automotive air conditioning","score":0.9279999732971191},{"id":"https://openalex.org/keywords/compressor-startup","display_name":"compressor startup","score":0.9340000152587891},{"id":"https://openalex.org/keywords/transient-response","display_name":"transient response","score":0.9959999918937683},{"id":"https://openalex.org/keywords/suction-and-discharge-pressure","display_name":"suction and discharge pressure","score":0.7720000147819519},{"id":"https://openalex.org/keywords/refrigerating-capacity","display_name":"refrigerating capacity","score":0.9589999914169312},{"id":"https://openalex.org/keywords/coefficient-of-performance","display_name":"coefficient of performance","score":0.9079999923706055},{"id":"https://openalex.org/keywords/test-bench","display_name":"test bench","score":0.43700000643730164}],"concepts":[{"id":"https://openalex.org/C131097465","wikidata":"https://www.wikidata.org/wiki/Q178898","display_name":"Gas compressor","level":2,"score":0.8236943483352661},{"id":"https://openalex.org/C103742991","wikidata":"https://www.wikidata.org/wiki/Q173725","display_name":"Air conditioning","level":2,"score":0.7943938374519348},{"id":"https://openalex.org/C2780799671","wikidata":"https://www.wikidata.org/wiki/Q17087362","display_name":"Transient (computer programming)","level":2,"score":0.7229634523391724},{"id":"https://openalex.org/C23795335","wikidata":"https://www.wikidata.org/wiki/Q1790295","display_name":"Suction","level":2,"score":0.6973187327384949},{"id":"https://openalex.org/C125989502","wikidata":"https://www.wikidata.org/wiki/Q5281443","display_name":"Discharge pressure","level":3,"score":0.6882458329200745},{"id":"https://openalex.org/C171146098","wikidata":"https://www.wikidata.org/wiki/Q124192","display_name":"Automotive engineering","level":1,"score":0.6239876747131348},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.4837512969970703},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.41556090116500854},{"id":"https://openalex.org/C39432304","wikidata":"https://www.wikidata.org/wiki/Q188847","display_name":"Environmental science","level":0,"score":0.3832857608795166},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.09870114922523499},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"mag:2356536498","doi":null,"is_oa":false,"landing_page_url":"http://caod.oriprobe.com/articles/10368970/Study_on_Transient_Characteristics_of_Rotary_Vane_Compressor_for_Autom.htm","pdf_url":null,"source":{"id":"https://openalex.org/S2764631204","display_name":"Fluid Machinery","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["cwts-core"],"host_organization":"https://openalex.org/P4324114407","host_organization_name":"Airwalk Publications","host_organization_lineage":["https://openalex.org/P4324114407"],"host_organization_lineage_names":["Airwalk Publications"],"type":"journal"},"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false,"raw_source_name":"Fluid Machinery","raw_type":null}],"best_oa_location":null,"sustainable_development_goals":[],"study_designs":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":0,"referenced_works":[],"related_works":["https://openalex.org/W3174674848","https://openalex.org/W2333060250","https://openalex.org/W3108020506","https://openalex.org/W2737687051","https://openalex.org/W158179824","https://openalex.org/W77344155","https://openalex.org/W2971651858","https://openalex.org/W2204845719","https://openalex.org/W3184666657","https://openalex.org/W2064938893"],"abstract_inverted_index":{"The":[0],"experiment":[1],"is":[2],"conducted":[3],"on":[4],"a":[5],"test-rig":[6],"of":[7,19,39,47],"compressor":[8],"for":[9],"automobile":[10,21],"air":[11,15,22],"conditioner":[12,23],"under":[13],"standard":[14],"condition,and":[16],"some":[17,51],"parameters":[18],"the":[20,44],"are":[24,49,54],"measured":[25],"during":[26],"startup,such":[27],"as":[28],"suction":[29],"and":[30,33,37],"discharge":[31,34],"temperature,suction":[32],"pressure,refrigerating":[35],"capacity":[36],"coefficient":[38],"performance.The":[40],"main":[41],"factors":[42],"influencing":[43],"transient":[45],"characteristics":[46],"startup":[48],"studied,and":[50],"reasonable":[52],"measures":[53],"proposed.":[55]},"cited_by_api_url":"https://api.openalex.org/works?filter=cites:W2356536498","counts_by_year":[],"updated_date":"2026-11-21T10:27:49.728292","created_date":"2016-06-24T00:00:00"}
