{"id":"https://openalex.org/W2353909366","doi":null,"title":"Technical research of secondary equipments' state monitoring in smart substation","display_name":"Technical research of secondary equipments' state monitoring in smart substation","alternate_titles":[],"publication_year":2015,"publication_date":"2015-01-01","ids":{"openalex":"https://openalex.org/W2353909366","mag":"2353909366"},"language":"en","primary_location":{"id":"mag:2353909366","doi":null,"is_oa":true,"landing_page_url":"https://oversea.cnki.net/kcms/detail/detail.aspx?dbcode=CJFD&filename=JDQW201507020","pdf_url":null,"source":{"id":"https://openalex.org/S2764567417","display_name":"Power System Protection and Control","issn_l":"1674-3415","issn":["1674-3415"],"is_oa":true,"is_in_doaj":true,"is_core":false,"listed_in":["doaj","poland-70","russia-white-list-2"],"host_organization":"https://openalex.org/P4361727523","host_organization_name":"Power System Protection and Control Press","host_organization_lineage":["https://openalex.org/P4361727523"],"host_organization_lineage_names":["Power System Protection and Control Press"],"type":"journal"},"license":"cc-by-nc","license_id":"https://openalex.org/licenses/cc-by-nc","version":null,"is_accepted":false,"is_published":false,"raw_source_name":"Power System Protection and Control","raw_type":null},"parent_works":[],"lineage":["https://openalex.org/W2353909366"],"child_works_count":0,"pull_notice_works":[],"type":"article","is_traditional":true,"indexed_in":[],"open_access":{"is_oa":true,"oa_status":"diamond","oa_url":"https://oversea.cnki.net/kcms/detail/detail.aspx?dbcode=CJFD&filename=JDQW201507020","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5048363251","display_name":"XU Changba","type":null,"orcid":null,"observed_orcids":[]},"acted_on_behalf_of":[],"institutions":[],"countries":[],"is_corresponding":true,"contributor_roles":[],"raw_author_name":"XU Changba","raw_affiliation_strings":["Shanghai Siyuan Hongrui Automation Co"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Shanghai Siyuan Hongrui Automation Co","institution_ids":[]}]}],"institutions":[],"countries_distinct_count":0,"institutions_distinct_count":0,"corresponding_author_ids":["https://openalex.org/A5048363251"],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.48,"has_fulltext":false,"cited_by_count":14,"reviewed_by_count":0,"citation_normalized_percentile":{"value":0.63158376,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":86,"max":96},"biblio":{"volume":null,"issue":null,"first_page":null,"last_page":null},"is_retracted":false,"is_pulled":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T12451","display_name":"Smart Grid and Power Systems","score":0.7426999807357788,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T12451","display_name":"Smart Grid and Power Systems","score":0.7426999807357788,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10972","display_name":"Power Systems Fault Detection","score":0.08669999986886978,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T14276","display_name":"Power Systems and Technologies","score":0.08550000190734863,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/smart-substation","display_name":"smart substation","score":0.9580000042915344},{"id":"https://openalex.org/keywords/secondary-equipment","display_name":"secondary equipment","score":0.8640000224113464},{"id":"https://openalex.org/keywords/state-monitoring","display_name":"state monitoring","score":0.8199999928474426},{"id":"https://openalex.org/keywords/state-maintenance","display_name":"state maintenance","score":0.6589999794960022},{"id":"https://openalex.org/keywords/iec-61850","display_name":"IEC 61850","score":0.9520000219345093},{"id":"https://openalex.org/keywords/fuzzy-comprehensive-evaluation","display_name":"fuzzy comprehensive evaluation","score":0.8050000071525574},{"id":"https://openalex.org/keywords/smart-components","display_name":"smart components","score":0.7020000219345093},{"id":"https://openalex.org/keywords/fault-diagnosis","display_name":"fault diagnosis","score":0.5559999942779541}],"concepts":[{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.6033378839492798},{"id":"https://openalex.org/C48103436","wikidata":"https://www.wikidata.org/wiki/Q599031","display_name":"State (computer science)","level":2,"score":0.48631271719932556},{"id":"https://openalex.org/C32802771","wikidata":"https://www.wikidata.org/wiki/Q2443617","display_name":"Port (circuit theory)","level":2,"score":0.4688882529735565},{"id":"https://openalex.org/C158379750","wikidata":"https://www.wikidata.org/wiki/Q214111","display_name":"Network packet","level":2,"score":0.43333128094673157},{"id":"https://openalex.org/C98045186","wikidata":"https://www.wikidata.org/wiki/Q205663","display_name":"Process (computing)","level":2,"score":0.43131518363952637},{"id":"https://openalex.org/C79403827","wikidata":"https://www.wikidata.org/wiki/Q3988","display_name":"Real-time computing","level":1,"score":0.38509100675582886},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.37588992714881897},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.3283538222312927},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.25380411744117737},{"id":"https://openalex.org/C31258907","wikidata":"https://www.wikidata.org/wiki/Q1301371","display_name":"Computer network","level":1,"score":0.21616840362548828},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.0},{"id":"https://openalex.org/C11413529","wikidata":"https://www.wikidata.org/wiki/Q8366","display_name":"Algorithm","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"mag:2353909366","doi":null,"is_oa":true,"landing_page_url":"https://oversea.cnki.net/kcms/detail/detail.aspx?dbcode=CJFD&filename=JDQW201507020","pdf_url":null,"source":{"id":"https://openalex.org/S2764567417","display_name":"Power System Protection and Control","issn_l":"1674-3415","issn":["1674-3415"],"is_oa":true,"is_in_doaj":true,"is_core":false,"listed_in":["doaj","poland-70","russia-white-list-2"],"host_organization":"https://openalex.org/P4361727523","host_organization_name":"Power System Protection and Control Press","host_organization_lineage":["https://openalex.org/P4361727523"],"host_organization_lineage_names":["Power System Protection and Control Press"],"type":"journal"},"license":"cc-by-nc","license_id":"https://openalex.org/licenses/cc-by-nc","version":null,"is_accepted":false,"is_published":false,"raw_source_name":"Power System Protection and Control","raw_type":null}],"best_oa_location":{"id":"mag:2353909366","doi":null,"is_oa":true,"landing_page_url":"https://oversea.cnki.net/kcms/detail/detail.aspx?dbcode=CJFD&filename=JDQW201507020","pdf_url":null,"source":{"id":"https://openalex.org/S2764567417","display_name":"Power System Protection and Control","issn_l":"1674-3415","issn":["1674-3415"],"is_oa":true,"is_in_doaj":true,"is_core":false,"listed_in":["doaj","poland-70","russia-white-list-2"],"host_organization":"https://openalex.org/P4361727523","host_organization_name":"Power System Protection and Control Press","host_organization_lineage":["https://openalex.org/P4361727523"],"host_organization_lineage_names":["Power System Protection and Control Press"],"type":"journal"},"license":"cc-by-nc","license_id":"https://openalex.org/licenses/cc-by-nc","version":null,"is_accepted":false,"is_published":false,"raw_source_name":"Power System Protection and Control","raw_type":null},"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/9","display_name":"Industry, innovation and infrastructure","score":0.8970999717712402}],"study_designs":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":0,"referenced_works":[],"related_works":["https://openalex.org/W3127511541","https://openalex.org/W2363893639","https://openalex.org/W2362887561","https://openalex.org/W3015759126","https://openalex.org/W2511343495","https://openalex.org/W3036842077","https://openalex.org/W4378805479","https://openalex.org/W4280617060","https://openalex.org/W2349519737","https://openalex.org/W2376453433"],"abstract_inverted_index":{"The":[0],"equipment's":[1],"state":[2,10,24,31,62],"monitoring":[3,25,89],"and":[4,26,49,112],"evaluation":[5,27,56,70],"is":[6,33,63,91],"the":[7,13,60,67,72,76,85,96,101,109],"foundation":[8],"of":[9,16,58,74,78],"maintenance.According":[11],"to":[12,40,44,99,123],"technical":[14],"features":[15],"smart":[17,29],"substation,this":[18],"paper":[19],"researches":[20],"on":[21],"secondary":[22],"equipments'":[23],"in":[28,93],"substation.Switch":[30],"information":[32],"acquired":[34],"with":[35,66,95],"IEC61850,the":[36],"switch":[37,61],"port":[38,50],"traffic,port":[39],"receiving":[41],"light":[42,46],"intensity,port":[43],"sending":[45],"intensity,working":[47],"temperature":[48],"error":[51],"rate":[52],"are":[53],"selected":[54],"as":[55],"indicator":[57],"switch,and":[59],"evaluated":[64],"comprehensively":[65],"fuzzy":[68],"comprehensive":[69],"method.For":[71],"problem":[73],"preventing":[75],"protection":[77],"export":[79],"trip":[80,103],"circuit":[81],"contact":[82],"adhesion,failure,and":[83],"forgetting":[84],"cast":[86],"plate,the":[87],"background":[88],"system":[90],"designed":[92],"conjunction":[94],"intelligent":[97,131],"component":[98,132],"realize":[100],"inspection":[102],"contact.For":[104],"SV,GOOSE":[105],"transceiver":[106],"anomaly":[107],"between":[108],"bay":[110,127],"layer":[111,128],"process":[113],"layer,it":[114],"presents":[115],"a":[116,126],"dependency":[117],"network":[118],"packet":[119],"analyzer":[120],"diagnostic":[121],"method":[122],"diagnose":[124],"out":[125],"device":[129],"or":[130],"failure.":[133]},"cited_by_api_url":"https://api.openalex.org/works?filter=cites:W2353909366","counts_by_year":[{"year":2024,"cited_by_count":1},{"year":2022,"cited_by_count":3},{"year":2021,"cited_by_count":2},{"year":2020,"cited_by_count":2},{"year":2019,"cited_by_count":2},{"year":2017,"cited_by_count":2},{"year":2016,"cited_by_count":2}],"updated_date":"2026-11-16T12:05:36.265796","created_date":"2016-06-24T00:00:00"}
