{"id":"https://openalex.org/W2348401359","doi":null,"title":"Design of PWM Flyback Power Supply by Using FAN6754A","display_name":"Design of PWM Flyback Power Supply by Using FAN6754A","publication_year":2011,"publication_date":"2011-01-01","ids":{"openalex":"https://openalex.org/W2348401359","mag":"2348401359"},"language":"en","primary_location":{"id":"mag:2348401359","doi":null,"is_oa":false,"landing_page_url":"http://en.cnki.com.cn/Article_en/CJFDTOTAL-DCYQ201110019.htm","pdf_url":null,"source":{"id":"https://openalex.org/S2764410550","display_name":"Electrical Measurement & Instrumentation","issn_l":"1001-1390","issn":["1001-1390"],"is_oa":false,"is_in_doaj":true,"is_core":false,"listed_in":["doaj"],"host_organization":"https://openalex.org/P4320800717","host_organization_name":"Technical Publications (NAID 618077)","host_organization_lineage":["https://openalex.org/P4320800717"],"host_organization_lineage_names":["Technical Publications (NAID 618077)"],"type":"journal"},"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false,"raw_source_name":"Electrical Measurement & Instrumentation","raw_type":null},"volume":null,"type":"article","is_traditional":true,"indexed_in":[],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5085549957","display_name":"Zhonghua Wei","orcid":"https://orcid.org/0000-0001-7349-9939","observed_orcids":["https://orcid.org/0000-0001-7349-9939"]},"institutions":[],"countries":[],"is_corresponding":true,"raw_author_name":"Zhonghua Wei","raw_affiliation_strings":["Electronic Info"],"raw_orcid":"https://orcid.org/0000-0001-7349-9939","affiliations":[{"raw_affiliation_string":"Electronic Info","institution_ids":[]}]}],"institutions":[],"countries_distinct_count":0,"institutions_distinct_count":0,"corresponding_author_ids":["https://openalex.org/A5085549957"],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":{"value":0.27837181,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":null,"last_page":null},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10175","display_name":"Advanced DC-DC Converters","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10175","display_name":"Advanced DC-DC Converters","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11444","display_name":"Electromagnetic Compatibility and Noise Suppression","score":0.0,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10323","display_name":"Analog and Mixed-Signal Circuit Design","score":0.0,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/flyback-converter","display_name":"flyback converter","score":0.8619999885559082},{"id":"https://openalex.org/keywords/peak-current-mode-control","display_name":"peak current mode control","score":0.7509999871253967},{"id":"https://openalex.org/keywords/transformer-design","display_name":"transformer design","score":0.9750000238418579},{"id":"https://openalex.org/keywords/isolation","display_name":"isolation","score":0.5479999780654907},{"id":"https://openalex.org/keywords/overvoltage-protection","display_name":"overvoltage protection","score":0.7580000162124634},{"id":"https://openalex.org/keywords/overcurrent-protection","display_name":"overcurrent protection","score":0.9869999885559082},{"id":"https://openalex.org/keywords/thermistor","display_name":"thermistor","score":0.4909999966621399},{"id":"https://openalex.org/keywords/output-voltage-regulation","display_name":"output voltage regulation","score":0.4569999873638153},{"id":"https://openalex.org/keywords/converter-efficiency","display_name":"converter efficiency","score":0.47699999809265137}],"concepts":[{"id":"https://openalex.org/C17321440","wikidata":"https://www.wikidata.org/wiki/Q184909","display_name":"Flyback transformer","level":4,"score":0.8185346126556396},{"id":"https://openalex.org/C166869088","wikidata":"https://www.wikidata.org/wiki/Q888791","display_name":"Flyback diode","level":5,"score":0.7165896892547607},{"id":"https://openalex.org/C103303742","wikidata":"https://www.wikidata.org/wiki/Q1293595","display_name":"Flyback converter","level":4,"score":0.6814380288124084},{"id":"https://openalex.org/C151799858","wikidata":"https://www.wikidata.org/wiki/Q587008","display_name":"Switched-mode power supply","level":3,"score":0.5917025208473206},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.5030726790428162},{"id":"https://openalex.org/C66322947","wikidata":"https://www.wikidata.org/wiki/Q11658","display_name":"Transformer","level":3,"score":0.49264246225357056},{"id":"https://openalex.org/C55118286","wikidata":"https://www.wikidata.org/wiki/Q634739","display_name":"Forward converter","level":4,"score":0.48424002528190613},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.4738864302635193},{"id":"https://openalex.org/C29210110","wikidata":"https://www.wikidata.org/wiki/Q177897","display_name":"Inductance","level":3,"score":0.45364853739738464},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.42077648639678955},{"id":"https://openalex.org/C92746544","wikidata":"https://www.wikidata.org/wiki/Q585184","display_name":"Pulse-width modulation","level":3,"score":0.4149937927722931},{"id":"https://openalex.org/C110706871","wikidata":"https://www.wikidata.org/wiki/Q851210","display_name":"Voltage regulator","level":3,"score":0.4138648211956024},{"id":"https://openalex.org/C150818752","wikidata":"https://www.wikidata.org/wiki/Q83804","display_name":"Buck converter","level":3,"score":0.41061824560165405},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.3987710773944855},{"id":"https://openalex.org/C78336795","wikidata":"https://www.wikidata.org/wiki/Q760134","display_name":"Boost converter","level":3,"score":0.18298718333244324}],"mesh":[],"locations_count":1,"locations":[{"id":"mag:2348401359","doi":null,"is_oa":false,"landing_page_url":"http://en.cnki.com.cn/Article_en/CJFDTOTAL-DCYQ201110019.htm","pdf_url":null,"source":{"id":"https://openalex.org/S2764410550","display_name":"Electrical Measurement & Instrumentation","issn_l":"1001-1390","issn":["1001-1390"],"is_oa":false,"is_in_doaj":true,"is_core":false,"listed_in":["doaj"],"host_organization":"https://openalex.org/P4320800717","host_organization_name":"Technical Publications (NAID 618077)","host_organization_lineage":["https://openalex.org/P4320800717"],"host_organization_lineage_names":["Technical Publications (NAID 618077)"],"type":"journal"},"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false,"raw_source_name":"Electrical Measurement & Instrumentation","raw_type":null}],"best_oa_location":null,"sustainable_development_goals":[],"study_designs":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":0,"referenced_works":[],"related_works":["https://openalex.org/W2988370582","https://openalex.org/W2388973331","https://openalex.org/W2355426092","https://openalex.org/W2386623673","https://openalex.org/W2363282557","https://openalex.org/W2362271646","https://openalex.org/W2377684685","https://openalex.org/W2942429633","https://openalex.org/W3128941456","https://openalex.org/W2366146220"],"abstract_inverted_index":{"The":[0],"working":[1,80],"characteristics":[2,101],"and":[3,54,60,72,79,112],"principles":[4,21],"of":[5,19,25,41,102,104],"a":[6],"novel":[7,30],"peak":[8],"current-mode":[9],"PWM":[10],"IC":[11],"FAN6754A":[12],"are":[13,63,82],"described.The":[14],"analysis":[15],"is":[16,35],"put":[17],"forward":[18],"design":[20,49,76],"in":[22,84],"operating":[23],"process":[24,81],"flyback":[26,31],"switching":[27,32],"power":[28,33],"supplies.A":[29],"supply":[34],"provided":[36],"to":[37],"meet":[38],"the":[39,42,85,96,100],"needs":[40],"secondary":[43],"circuit,with":[44],"emphasis":[45],"on":[46],"its":[47],"transformer":[48],"including":[50],"inductance":[51],"current,transformer":[52],"type,windings":[53],"gap":[55],"length":[56],"etc.The":[57],"voltage":[58,68,107,113],"control":[59],"stable":[61],"output":[62],"realized":[64],"by":[65],"using":[66],"three-terminal":[67],"regulator":[69],"TL431,input/output":[70],"isolation":[71],"feedback":[73],"with":[74],"opti-coupler.Its":[75],"principle,module":[77],"functions":[78],"analyzed.And":[83],"circuit":[86],"there":[87],"exists":[88],"thermistors,over-voltage,and":[89],"over-current":[90],"protection":[91],"etc.Experimental":[92],"results":[93],"show":[94],"that":[95],"designed":[97],"converter":[98],"has":[99],"efficiency":[103],"near":[105],"89%,steady,low":[106],"ripples,high":[108],"load":[109],"regulation":[110],"rate":[111,115],"adjustment":[114],"etc.":[116]},"counts_by_year":[],"updated_date":"2026-07-28T07:46:37.118299","created_date":"2016-06-24T00:00:00"}
