{"id":"https://openalex.org/W2340323369","doi":null,"title":"VENTILATION, ENERGY AND INDOOR AIR QUALITY","display_name":"VENTILATION, ENERGY AND INDOOR AIR QUALITY","publication_year":2002,"publication_date":"2002-01-01","ids":{"openalex":"https://openalex.org/W2340323369","mag":"2340323369"},"language":"en","primary_location":{"id":"mag:2340323369","doi":null,"is_oa":false,"landing_page_url":"https://www.irbnet.de/daten/iconda/CIB7771.pdf","pdf_url":null,"source":null,"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":null},"volume":null,"type":"article","is_traditional":true,"indexed_in":[],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5070323960","display_name":"Olli Sepp\u00e4nen","orcid":"https://orcid.org/0000-0002-2008-5924","observed_orcids":["https://orcid.org/0000-0002-2008-5924"]},"institutions":[],"countries":[],"is_corresponding":true,"raw_author_name":"Olli Sepp\u00e4nen","raw_affiliation_strings":[],"raw_orcid":"https://orcid.org/0000-0002-2008-5924","affiliations":[]}],"institutions":[],"countries_distinct_count":0,"institutions_distinct_count":0,"corresponding_author_ids":["https://openalex.org/A5070323960"],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.2398,"has_fulltext":false,"cited_by_count":4,"citation_normalized_percentile":{"value":0.51935399,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":88,"max":93},"biblio":{"volume":null,"issue":null,"first_page":null,"last_page":null},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11002","display_name":"Indoor Air Quality and Microbial Exposure","score":0.9843999743461609,"subfield":{"id":"https://openalex.org/subfields/2307","display_name":"Health, Toxicology and Mutagenesis"},"field":{"id":"https://openalex.org/fields/23","display_name":"Environmental Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11002","display_name":"Indoor Air Quality and Microbial Exposure","score":0.9843999743461609,"subfield":{"id":"https://openalex.org/subfields/2307","display_name":"Health, Toxicology and Mutagenesis"},"field":{"id":"https://openalex.org/fields/23","display_name":"Environmental Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10121","display_name":"Building Energy and Comfort Optimization","score":0.008200000040233135,"subfield":{"id":"https://openalex.org/subfields/2215","display_name":"Building and Construction"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10990","display_name":"Infection Control and Ventilation","score":0.0038999998942017555,"subfield":{"id":"https://openalex.org/subfields/2740","display_name":"Pulmonary and Respiratory Medicine"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/ventilation","display_name":"ventilation","score":0.6759999990463257},{"id":"https://openalex.org/keywords/indoor-air-quality","display_name":"indoor air quality","score":0.8289999961853027},{"id":"https://openalex.org/keywords/energy-consumption","display_name":"energy consumption","score":0.6370000243186951},{"id":"https://openalex.org/keywords/sick-building-syndrome","display_name":"sick building syndrome","score":0.7620000243186951},{"id":"https://openalex.org/keywords/air-conditioning","display_name":"air conditioning","score":0.6959999799728394},{"id":"https://openalex.org/keywords/air-tightness","display_name":"air tightness","score":0.8199999928474426},{"id":"https://openalex.org/keywords/cold-climate","display_name":"cold climate","score":0.5519999861717224},{"id":"https://openalex.org/keywords/respiratory-diseases","display_name":"respiratory diseases","score":0.574999988079071},{"id":"https://openalex.org/keywords/air-handling-systems","display_name":"air handling systems","score":0.746999979019165},{"id":"https://openalex.org/keywords/building-commissioning","display_name":"building commissioning","score":0.5839999914169312},{"id":"https://openalex.org/keywords/ventilation-rate","display_name":"ventilation rate","score":0.31299999356269836}],"concepts":[{"id":"https://openalex.org/C114997826","wikidata":"https://www.wikidata.org/wiki/Q1072290","display_name":"Sick building syndrome","level":3,"score":0.8030565977096558},{"id":"https://openalex.org/C200457457","wikidata":"https://www.wikidata.org/wiki/Q584049","display_name":"Ventilation (architecture)","level":2,"score":0.7582994699478149},{"id":"https://openalex.org/C65469","wikidata":"https://www.wikidata.org/wiki/Q905504","display_name":"Indoor air quality","level":2,"score":0.6651690602302551},{"id":"https://openalex.org/C103742991","wikidata":"https://www.wikidata.org/wiki/Q173725","display_name":"Air conditioning","level":2,"score":0.5229971408843994},{"id":"https://openalex.org/C196803488","wikidata":"https://www.wikidata.org/wiki/Q4986592","display_name":"Building envelope","level":3,"score":0.430225670337677},{"id":"https://openalex.org/C17005505","wikidata":"https://www.wikidata.org/wiki/Q11164636","display_name":"Energy recovery ventilation","level":4,"score":0.42728400230407715},{"id":"https://openalex.org/C39432304","wikidata":"https://www.wikidata.org/wiki/Q188847","display_name":"Environmental science","level":0,"score":0.42441385984420776},{"id":"https://openalex.org/C71924100","wikidata":"https://www.wikidata.org/wiki/Q11190","display_name":"Medicine","level":0,"score":0.4013177156448364},{"id":"https://openalex.org/C99454951","wikidata":"https://www.wikidata.org/wiki/Q932068","display_name":"Environmental health","level":1,"score":0.35757389664649963},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.2650811970233917},{"id":"https://openalex.org/C87717796","wikidata":"https://www.wikidata.org/wiki/Q146326","display_name":"Environmental engineering","level":1,"score":0.2328759729862213},{"id":"https://openalex.org/C122346748","wikidata":"https://www.wikidata.org/wiki/Q1798773","display_name":"HVAC","level":3,"score":0.2161233127117157},{"id":"https://openalex.org/C153294291","wikidata":"https://www.wikidata.org/wiki/Q25261","display_name":"Meteorology","level":1,"score":0.11154341697692871},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C204530211","wikidata":"https://www.wikidata.org/wiki/Q752823","display_name":"Thermal","level":2,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"mag:2340323369","doi":null,"is_oa":false,"landing_page_url":"https://www.irbnet.de/daten/iconda/CIB7771.pdf","pdf_url":null,"source":null,"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":null}],"best_oa_location":null,"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/3","score":0.8048999905586243,"display_name":"Good health and well-being"}],"study_designs":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":14,"referenced_works":["https://openalex.org/W210953004","https://openalex.org/W786264152","https://openalex.org/W1937446719","https://openalex.org/W1969624050","https://openalex.org/W2020548779","https://openalex.org/W2055434434","https://openalex.org/W2099290073","https://openalex.org/W2118071847","https://openalex.org/W2127082595","https://openalex.org/W2161463298","https://openalex.org/W2167394777","https://openalex.org/W2305804301","https://openalex.org/W2469666412","https://openalex.org/W2766560538"],"related_works":["https://openalex.org/W2169053172","https://openalex.org/W4300663027","https://openalex.org/W2990765978","https://openalex.org/W7061613105","https://openalex.org/W7099669468","https://openalex.org/W2136565245","https://openalex.org/W2461736336","https://openalex.org/W4254680755","https://openalex.org/W30517308","https://openalex.org/W3039803327"],"abstract_inverted_index":{"As":[0],"ventilation":[1,11,49,70,108],"is":[2,116],"a":[3,44],"significant":[4],"consumer":[5],"of":[6,10,95,107,113,138,151],"energy":[7,19,31],"the":[8,18,22,52,93,105,111,132,148],"rates":[9,71],"have":[12,39,72],"often":[13],"been":[14,67,102],"minimised,":[15],"particularly":[16,34,144],"after":[17],"crisis":[20],"in":[21,25,36,58,118,122,131],"early":[23],"70\u2019s,":[24],"order":[26],"to":[27],"reduce":[28],"equipment":[29],"and":[30,86,136],"costs.":[32],"Buildings,":[33],"those":[35],"cold":[37],"climates,":[38],"also":[40,101],"become":[41],"more":[42],"airtight":[43],"factor":[45],"which":[46],"has":[47,56,66,100],"reduced":[48],"airflow":[50],"through":[51],"building":[53,81,97],"envelope.":[54],"This":[55],"caused":[57],"many":[59,91],"countries":[60],"indoor":[61],"air":[62,88,139,152],"quality":[63],"problems.":[64],"It":[65],"shown":[68],"that":[69,129],"adverse":[73],"effects":[74,150],"on":[75,79,84],"communicable":[76],"respiratory":[77],"illnesses;":[78],"sick":[80,96],"syndrome":[82,98],"symptoms;":[83],"productivity":[85],"perceived":[87],"quality.":[89],"In":[90],"studies,":[92],"prevalence":[94,112],"symptoms":[99,115],"associated":[103],"with":[104],"characteristics":[106],"systems.":[109,154],"Often":[110],"SBS":[114],"higher":[117],"air-conditioned":[119],"buildings":[120],"than":[121],"naturally":[123],"ventilated":[124],"buildings.":[125],"The":[126],"evidence":[127],"suggests":[128],"improvements":[130],"hygiene,":[133],"commissioning,":[134],"operation":[135],"maintenance":[137],"handling":[140],"systems":[141],"may":[142],"be":[143],"important":[145],"for":[146],"reducing":[147],"negative":[149],"conditioning":[153]},"counts_by_year":[{"year":2023,"cited_by_count":1},{"year":2022,"cited_by_count":1},{"year":2018,"cited_by_count":1}],"updated_date":"2026-11-04T10:54:05.112534","created_date":"2016-06-24T00:00:00"}
