{"id":"https://openalex.org/W2299891599","doi":null,"title":"Calculation of pressure rise in electrical installations due to internal arcs considering SF 6-air mixtures and arc energy absorbers","display_name":"Calculation of pressure rise in electrical installations due to internal arcs considering SF 6-air mixtures and arc energy absorbers","publication_year":2010,"publication_date":"2010-01-01","ids":{"openalex":"https://openalex.org/W2299891599","mag":"2299891599"},"language":"en","primary_location":{"id":"pmh:oai:publications.rwth-aachen.de:51647","doi":null,"is_oa":true,"landing_page_url":"https://publications.rwth-aachen.de/record/51647","pdf_url":null,"source":{"id":"https://openalex.org/S4306401033","display_name":"RWTH Publications (RWTH Aachen)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I887968799","host_organization_name":"RWTH Aachen University","host_organization_lineage":["https://openalex.org/I887968799"],"host_organization_lineage_names":[],"type":"repository"},"license":"other-oa","license_id":"https://openalex.org/licenses/other-oa","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Aachen : Mainz, Aachener Beitr\u00e4ge zur Hochspannungstechnik 14, III, 125 S. : Ill., graph. Darst. (2010). = Zugl.: Aachen, Techn. Hochsch., Diss., 2010","raw_type":"info:eu-repo/semantics/doctoralThesis"},"volume":null,"type":"dissertation","is_traditional":true,"indexed_in":[],"open_access":{"is_oa":true,"oa_status":"green","oa_url":"https://publications.rwth-aachen.de/record/51647","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5023715219","display_name":"Kittipong Anantavanich","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Kittipong Anantavanich","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"last","author":{"id":"https://openalex.org/A5034814851","display_name":"Gerhard J. Pietsch","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Gerhard J. Pietsch","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]}],"institutions":[],"countries_distinct_count":0,"institutions_distinct_count":0,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":null,"has_fulltext":false,"cited_by_count":21,"citation_normalized_percentile":null,"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":null,"last_page":null},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T12077","display_name":"Vacuum and Plasma Arcs","score":0.9193999767303467,"subfield":{"id":"https://openalex.org/subfields/3107","display_name":"Atomic and Molecular Physics, and Optics"},"field":{"id":"https://openalex.org/fields/31","display_name":"Physics and Astronomy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T12077","display_name":"Vacuum and Plasma Arcs","score":0.9193999767303467,"subfield":{"id":"https://openalex.org/subfields/3107","display_name":"Atomic and Molecular Physics, and Optics"},"field":{"id":"https://openalex.org/fields/31","display_name":"Physics and Astronomy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11317","display_name":"Fire dynamics and safety research","score":0.05350000038743019,"subfield":{"id":"https://openalex.org/subfields/2213","display_name":"Safety, Risk, Reliability and Quality"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12737","display_name":"Electrical Fault Detection and Protection","score":0.002099999925121665,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/pressure-increase","display_name":"pressure rise","score":0.8309999704360962},{"id":"https://openalex.org/keywords/electrical-installations","display_name":"electrical installations","score":0.5799999833106995},{"id":"https://openalex.org/keywords/overpressure","display_name":"overpressure","score":0.5509999990463257},{"id":"https://openalex.org/keywords/heat-sinks","display_name":"heat sinks","score":0.7459999918937683},{"id":"https://openalex.org/keywords/flow-resistance","display_name":"flow resistance","score":0.9070000052452087},{"id":"https://openalex.org/keywords/computational-fluid-dynamics","display_name":"computational fluid dynamics","score":0.6100000143051147},{"id":"https://openalex.org/keywords/gas-flow-modeling","display_name":"gas flow modeling","score":0.39399999380111694}],"concepts":[{"id":"https://openalex.org/C114375839","wikidata":"https://www.wikidata.org/wiki/Q207456","display_name":"Electric arc","level":3,"score":0.7442322969436646},{"id":"https://openalex.org/C29452850","wikidata":"https://www.wikidata.org/wiki/Q3823104","display_name":"Overpressure","level":2,"score":0.7121013402938843},{"id":"https://openalex.org/C93893174","wikidata":"https://www.wikidata.org/wiki/Q1273786","display_name":"Switchgear","level":2,"score":0.7108139991760254},{"id":"https://openalex.org/C83415579","wikidata":"https://www.wikidata.org/wiki/Q161973","display_name":"Arc (geometry)","level":2,"score":0.5077763199806213},{"id":"https://openalex.org/C116915560","wikidata":"https://www.wikidata.org/wiki/Q83504","display_name":"Nuclear engineering","level":1,"score":0.5009164810180664},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.4406055808067322},{"id":"https://openalex.org/C57879066","wikidata":"https://www.wikidata.org/wiki/Q41217","display_name":"Mechanics","level":1,"score":0.3926301598548889},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.3904304504394531},{"id":"https://openalex.org/C171146098","wikidata":"https://www.wikidata.org/wiki/Q124192","display_name":"Automotive engineering","level":1,"score":0.33156514167785645},{"id":"https://openalex.org/C39432304","wikidata":"https://www.wikidata.org/wiki/Q188847","display_name":"Environmental science","level":0,"score":0.3284091353416443},{"id":"https://openalex.org/C17525397","wikidata":"https://www.wikidata.org/wiki/Q176140","display_name":"Electrode","level":2,"score":0.14696288108825684},{"id":"https://openalex.org/C185592680","wikidata":"https://www.wikidata.org/wiki/Q2329","display_name":"Chemistry","level":0,"score":0.09683573246002197},{"id":"https://openalex.org/C97355855","wikidata":"https://www.wikidata.org/wiki/Q11473","display_name":"Thermodynamics","level":1,"score":0.09363409876823425},{"id":"https://openalex.org/C147789679","wikidata":"https://www.wikidata.org/wiki/Q11372","display_name":"Physical chemistry","level":1,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0}],"mesh":[],"locations_count":2,"locations":[{"id":"pmh:oai:publications.rwth-aachen.de:51647","doi":null,"is_oa":true,"landing_page_url":"https://publications.rwth-aachen.de/record/51647","pdf_url":null,"source":{"id":"https://openalex.org/S4306401033","display_name":"RWTH Publications (RWTH Aachen)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I887968799","host_organization_name":"RWTH Aachen University","host_organization_lineage":["https://openalex.org/I887968799"],"host_organization_lineage_names":[],"type":"repository"},"license":"other-oa","license_id":"https://openalex.org/licenses/other-oa","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Aachen : Mainz, Aachener Beitr\u00e4ge zur Hochspannungstechnik 14, III, 125 S. : Ill., graph. Darst. (2010). = Zugl.: Aachen, Techn. Hochsch., Diss., 2010","raw_type":"info:eu-repo/semantics/doctoralThesis"},{"id":"mag:2299891599","doi":null,"is_oa":false,"landing_page_url":"https://publications.rwth-aachen.de/record/51647/files/3206.pdf","pdf_url":null,"source":null,"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":null}],"best_oa_location":{"id":"pmh:oai:publications.rwth-aachen.de:51647","doi":null,"is_oa":true,"landing_page_url":"https://publications.rwth-aachen.de/record/51647","pdf_url":null,"source":{"id":"https://openalex.org/S4306401033","display_name":"RWTH Publications (RWTH Aachen)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I887968799","host_organization_name":"RWTH Aachen University","host_organization_lineage":["https://openalex.org/I887968799"],"host_organization_lineage_names":[],"type":"repository"},"license":"other-oa","license_id":"https://openalex.org/licenses/other-oa","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Aachen : Mainz, Aachener Beitr\u00e4ge zur Hochspannungstechnik 14, III, 125 S. : Ill., graph. Darst. (2010). = Zugl.: Aachen, Techn. Hochsch., Diss., 2010","raw_type":"info:eu-repo/semantics/doctoralThesis"},"sustainable_development_goals":[{"display_name":"Affordable and clean energy","id":"https://metadata.un.org/sdg/7","score":0.4000000059604645}],"study_designs":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":45,"referenced_works":["https://openalex.org/W587297200","https://openalex.org/W621452971","https://openalex.org/W645729583","https://openalex.org/W1490011997","https://openalex.org/W1507466384","https://openalex.org/W1523480373","https://openalex.org/W1597944220","https://openalex.org/W1604226382","https://openalex.org/W1713825393","https://openalex.org/W1934779262","https://openalex.org/W1965480470","https://openalex.org/W1977507853","https://openalex.org/W1981401379","https://openalex.org/W1982566634","https://openalex.org/W2008195928","https://openalex.org/W2008329925","https://openalex.org/W2030206533","https://openalex.org/W2050323896","https://openalex.org/W2051193921","https://openalex.org/W2055444566","https://openalex.org/W2062392012","https://openalex.org/W2068507361","https://openalex.org/W2070215586","https://openalex.org/W2077007998","https://openalex.org/W2093743524","https://openalex.org/W2098868714","https://openalex.org/W2112122346","https://openalex.org/W2112217311","https://openalex.org/W2114114159","https://openalex.org/W2119138376","https://openalex.org/W2122709917","https://openalex.org/W2155016636","https://openalex.org/W2165128316","https://openalex.org/W2167398005","https://openalex.org/W2250105847","https://openalex.org/W2479410395","https://openalex.org/W2520461684","https://openalex.org/W2529079547","https://openalex.org/W2543317682","https://openalex.org/W2565198913","https://openalex.org/W2731166448","https://openalex.org/W2759085566","https://openalex.org/W2788495115","https://openalex.org/W3093382014","https://openalex.org/W3184518629"],"related_works":["https://openalex.org/W2343588562","https://openalex.org/W2543317682","https://openalex.org/W2768475236","https://openalex.org/W2213164721","https://openalex.org/W2237418712","https://openalex.org/W2994841280","https://openalex.org/W2753769605","https://openalex.org/W2981014779","https://openalex.org/W2312466852","https://openalex.org/W1923792141"],"abstract_inverted_index":{"Internal":[0],"arcs":[1],"cause":[2],"sudden":[3],"temperature":[4],"and":[5,97,168,190,207,213,221,248,267,304,313,319],"thus":[6],"pressure":[7,53,66,74,144,289],"increase":[8],"in":[9,47,56,146,229,329],"electrical":[10],"installations,":[11],"which":[12,69,92,140,293],"may":[13],"endanger":[14],"personnel,":[15],"installation":[16],"rooms":[17,318],"or":[18,51,128],"buildings":[19],"as":[20,22],"well":[21],"the":[23,88,98,107,147,166,179,222,234,251,257,272,286],"security":[24],"of":[25,38,86,110,149,157,162,170,181,196,224,250,256,259,288,317],"power":[26,49],"supply.":[27],"Overpressure":[28],"can":[29],"be":[30,124],"controlled":[31],"by":[32,45,52,263,326],"e.g.":[33],"relief":[34],"openings.":[35,320],"The":[36,154,254],"proof":[37],"internal":[39,78,150],"arc":[40,130,182,225],"withstand":[41],"is":[42,113,116,165,178,243,261,291,294],"usually":[43],"performed":[44],"tests":[46,59],"high":[48],"laboratories":[50],"calculations":[54],"especially":[55,117],"cases,":[57],"where":[58],"are":[60,70,85,133,141,152,193,211,217,227,324],"impractical.":[61],"Nowadays,":[62],"there":[63],"exist":[64],"reliable":[65,171,238,308],"calculation":[67,90,100,231,274,322,333],"methods,":[68],"able":[71,299],"to":[72,77,123,201,297,300],"determine":[73],"rise":[75,145],"due":[76],"arcing.":[79],"For":[80,185],"practical":[81],"applications,":[82],"two":[83],"methods":[84,112,232,323],"importance,":[87],"CFD":[89],"method,":[91,275],"provides":[93],"spatially":[94,103],"resolved":[95],"results,":[96],"standard":[99,273],"method":[101],"providing":[102],"averaged":[104],"results.":[105,334],"However,":[106],"application":[108],"range":[109],"these":[111],"limited.":[114],"This":[115],"true":[118],"if":[119,129],"SF6-air":[120,159,219,302],"mixtures":[121,220,303],"have":[122],"considered":[125,194],"(SF6-insulated":[126],"switchgear)":[127],"energy":[131,183],"absorbers":[132,226,260,305],"installed.":[134],"In":[135,199],"this":[136,186],"thesis,":[137],"both":[138,203,230],"effects,":[139],"important":[142],"for":[143,233,285],"case":[148],"arcing,":[151],"treated.":[153],"key":[155],"point":[156],"modelling":[158,180],"mixture":[160],"flows":[161],"changing":[163],"composition":[164],"generation":[167],"treatment":[169],"gas":[172,239,309],"data.":[173,240],"A":[174],"further":[175],"main":[176],"focus":[177],"absorbers.":[184],"purpose,":[187],"heat":[188,265],"absorption":[189],"flow":[191],"resistance":[192],"first":[195,235],"all":[197],"separately.":[198],"order":[200],"describe":[202],"effects":[204],"simultaneously,":[205],"existing":[206],"improved":[208,278],"model":[209,215],"approaches":[210],"evaluated":[212],"appropriate":[214],"combinations":[216],"proposed.":[218],"effect":[223,258],"implemented":[228],"time":[236],"with":[237,332],"Special":[241],"care":[242],"taken":[244],"on":[245,271,307],"data":[246],"handling":[247],"modification":[249],"equation":[252],"systems.":[253],"inclusion":[255],"achieved":[262],"considering":[264],"sinks":[266],"friction":[268],"forces.":[269],"Based":[270],"a":[276],"versatile":[277],"software":[279],"tool":[280],"(Improved":[281],"Standard":[282],"Calculation":[283],"Method)":[284],"determination":[287],"developments":[290],"developed,":[292],"fast,":[295],"easy":[296],"handle,":[298],"treat":[301],"based":[306],"data,":[310],"platform":[311],"independent":[312],"including":[314],"any":[315],"number":[316],"Both":[321],"validated":[325],"comparing":[327],"measurements":[328],"different":[330],"arrangements":[331]},"counts_by_year":[{"year":2024,"cited_by_count":1},{"year":2021,"cited_by_count":1},{"year":2019,"cited_by_count":2},{"year":2018,"cited_by_count":1},{"year":2017,"cited_by_count":3},{"year":2015,"cited_by_count":3},{"year":2014,"cited_by_count":4},{"year":2013,"cited_by_count":3}],"updated_date":"2026-09-11T09:22:31.653822","created_date":"2016-06-24T00:00:00"}
