{"id":"https://openalex.org/W2280817536","doi":"https://doi.org/10.1061/9780784408452","title":"Reliability-Based Design of Utility Pole Structures","display_name":"Reliability-Based Design of Utility Pole Structures","alternate_titles":[],"publication_year":2006,"publication_date":"2006-08-30","ids":{"openalex":"https://openalex.org/W2280817536","doi":"https://doi.org/10.1061/9780784408452","mag":"2280817536"},"language":"en","primary_location":{"id":"doi:10.1061/9780784408452","doi":"https://doi.org/10.1061/9780784408452","is_oa":false,"landing_page_url":"https://doi.org/10.1061/9780784408452","pdf_url":null,"source":{"id":"https://openalex.org/S4306462827","display_name":"American Society of Civil Engineers eBooks","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/P4310315747","host_organization_name":"American Society of Civil Engineers","host_organization_lineage":["https://openalex.org/P4310315747"],"host_organization_lineage_names":["American Society of Civil Engineers"],"type":"ebook platform"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":null,"raw_type":"monograph"},"parent_works":[],"lineage":["https://openalex.org/W2280817536"],"child_works_count":10,"type":"book","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5031435708","display_name":"Habib J. Dagher","orcid":"https://orcid.org/0000-0003-1734-4515","observed_orcids":["https://orcid.org/0000-0003-1734-4515"]},"institutions":[],"countries":[],"is_corresponding":true,"contributor_roles":[],"raw_author_name":"Dagher, Habib","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]}],"institutions":[],"countries_distinct_count":0,"institutions_distinct_count":0,"corresponding_author_ids":["https://openalex.org/A5031435708"],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.2671,"has_fulltext":false,"cited_by_count":54,"citation_normalized_percentile":{"value":0.66480447,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":92,"max":98},"biblio":{"volume":null,"issue":null,"first_page":null,"last_page":null},"is_retracted":false,"is_pulled":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10928","display_name":"Probabilistic and Robust Engineering Design","score":0.8901000022888184,"subfield":{"id":"https://openalex.org/subfields/2206","display_name":"Computational Mechanics"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10928","display_name":"Probabilistic and Robust Engineering Design","score":0.8901000022888184,"subfield":{"id":"https://openalex.org/subfields/2206","display_name":"Computational Mechanics"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12086","display_name":"Structural Integrity and Reliability Analysis","score":0.04600000008940697,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11941","display_name":"Power System Reliability and Maintenance","score":0.018300000578165054,"subfield":{"id":"https://openalex.org/subfields/2213","display_name":"Safety, Risk, Reliability and Quality"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/utility-poles","display_name":"utility poles","score":0.6779999732971191},{"id":"https://openalex.org/keywords/reliability-based-design","display_name":"reliability-based design","score":0.9559999704360962},{"id":"https://openalex.org/keywords/pole-structure","display_name":"pole structure","score":0.6510000228881836},{"id":"https://openalex.org/keywords/transmission-and-distribution-lines","display_name":"transmission and distribution lines","score":0.6200000047683716},{"id":"https://openalex.org/keywords/structural-reliability","display_name":"structural reliability","score":0.531000018119812},{"id":"https://openalex.org/keywords/pole-design","display_name":"pole design","score":0.6299999952316284}],"concepts":[{"id":"https://openalex.org/C43214815","wikidata":"https://www.wikidata.org/wiki/Q7310987","display_name":"Reliability (semiconductor)","level":3,"score":0.8154051303863525},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.6916452050209045},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.45603644847869873},{"id":"https://openalex.org/C2987092418","wikidata":"https://www.wikidata.org/wiki/Q62517323","display_name":"Structural reliability","level":3,"score":0.4503815770149231},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.4141015410423279},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.06723353266716003},{"id":"https://openalex.org/C49937458","wikidata":"https://www.wikidata.org/wiki/Q2599292","display_name":"Probabilistic logic","level":2,"score":0.0},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1061/9780784408452","doi":"https://doi.org/10.1061/9780784408452","is_oa":false,"landing_page_url":"https://doi.org/10.1061/9780784408452","pdf_url":null,"source":{"id":"https://openalex.org/S4306462827","display_name":"American Society of Civil Engineers eBooks","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/P4310315747","host_organization_name":"American Society of Civil Engineers","host_organization_lineage":["https://openalex.org/P4310315747"],"host_organization_lineage_names":["American Society of Civil Engineers"],"type":"ebook platform"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":null,"raw_type":"monograph"}],"best_oa_location":null,"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/9","score":0.7207000255584717,"display_name":"Industry, innovation and infrastructure"}],"study_designs":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":10,"referenced_works":["https://openalex.org/W1973429805","https://openalex.org/W2014208555","https://openalex.org/W2036576823","https://openalex.org/W2044167851","https://openalex.org/W2067274372","https://openalex.org/W2140481308","https://openalex.org/W2314084555","https://openalex.org/W2411470597","https://openalex.org/W2791708204","https://openalex.org/W3022793395"],"related_works":["https://openalex.org/W2325409323","https://openalex.org/W1544729644","https://openalex.org/W14736609","https://openalex.org/W2335328939","https://openalex.org/W2106151974","https://openalex.org/W2126514934","https://openalex.org/W105671876","https://openalex.org/W2083038709","https://openalex.org/W1594442863","https://openalex.org/W2315713888"],"abstract_inverted_index":{"Reliability-Based":[0],"Design":[1],"of":[2,14,55],"Utility":[3],"Pole":[4],"Structures":[5],"provides":[6,37],"state-of":[7],"the-art":[8],"technical":[9],"information":[10],"on":[11],"the":[12],"design":[13,44,66],"utility":[15],"pole":[16,72],"structures.":[17],"Among":[18],"other":[19],"useful":[20],"features,":[21],"this":[22,68],"manual":[23,69],"demonstrates":[24],"how":[25],"poles":[26],"differing":[27],"in":[28],"material":[29],"can":[30],"be":[31],"designed":[32],"to":[33],"equivalent":[34],"reliability":[35],"levels,":[36],"means":[38],"for":[39,46],"quantifying":[40],"adjusting":[41],"reliability,":[42],"offers":[43],"incentives":[45],"more":[47],"reliable":[48],"poles,":[49],"and":[50,53,64,79,81],"facilitates":[51],"innovation":[52],"introduction":[54],"new":[56],"material.":[57],"With":[58],"its":[59],"technically":[60],"innovative":[61],"subject":[62],"matter":[63],"detailed":[65],"examples,":[67],"will":[70],"benefit":[71],"manufacturers":[73],"as":[74,76],"well":[75],"electrical,":[77],"structural,":[78],"transmission":[80],"distribution":[82],"engineers.":[83]},"cited_by_api_url":"https://api.openalex.org/works?filter=cites:W2280817536","counts_by_year":[{"year":2026,"cited_by_count":3},{"year":2025,"cited_by_count":2},{"year":2024,"cited_by_count":2},{"year":2023,"cited_by_count":6},{"year":2022,"cited_by_count":3},{"year":2021,"cited_by_count":5},{"year":2020,"cited_by_count":7},{"year":2019,"cited_by_count":3},{"year":2018,"cited_by_count":3},{"year":2017,"cited_by_count":3},{"year":2016,"cited_by_count":3},{"year":2015,"cited_by_count":2},{"year":2014,"cited_by_count":5},{"year":2013,"cited_by_count":2},{"year":2012,"cited_by_count":3}],"updated_date":"2026-11-16T12:05:36.265796","created_date":"2016-06-24T00:00:00"}
