{"id":"https://openalex.org/W2280439809","doi":"https://doi.org/10.1109/icacact.2014.7223491","title":"Experience with 550 kV current transformers","display_name":"Experience with 550 kV current transformers","publication_year":2015,"publication_date":"2015-08-01","ids":{"openalex":"https://openalex.org/W2280439809","doi":"https://doi.org/10.1109/icacact.2014.7223491","mag":"2280439809"},"language":"en","primary_location":{"id":"doi:10.1109/icacact.2014.7223491","doi":"https://doi.org/10.1109/icacact.2014.7223491","is_oa":false,"landing_page_url":"https://doi.org/10.1109/icacact.2014.7223491","pdf_url":null,"source":{"id":"https://openalex.org/S7407086244","display_name":"IEEE Electrical Insulation Conference (EIC)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2015 IEEE Electrical Insulation Conference (EIC)","raw_type":"proceedings-article"},"volume":null,"type":"conference-paper","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5019522381","display_name":"William McDermid","orcid":"https://orcid.org/0000-0001-8691-0491","observed_orcids":["https://orcid.org/0000-0001-8691-0491"]},"institutions":[{"id":"https://openalex.org/I33814908","display_name":"Manitoba Hydro","ror":"https://ror.org/03y90jx90","country_code":"CA","type":"company","lineage":["https://openalex.org/I33814908"]}],"countries":["CA"],"is_corresponding":false,"raw_author_name":"W. McDermid","raw_affiliation_strings":["Manitoba Hydro, 1510 Chewier Boulevard, Winnipeg, MB Canada R3T 1Y6"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Manitoba Hydro, 1510 Chewier Boulevard, Winnipeg, MB Canada R3T 1Y6","institution_ids":["https://openalex.org/I33814908"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5050759751","display_name":"T. Black","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I33814908","display_name":"Manitoba Hydro","ror":"https://ror.org/03y90jx90","country_code":"CA","type":"company","lineage":["https://openalex.org/I33814908"]}],"countries":["CA"],"is_corresponding":false,"raw_author_name":"T. Black","raw_affiliation_strings":["Manitoba Hydro, 1510 Chevrier Boulevard, Winnipeg, MB Canada R3T 2P4"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Manitoba Hydro, 1510 Chevrier Boulevard, Winnipeg, MB Canada R3T 2P4","institution_ids":["https://openalex.org/I33814908"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":["https://openalex.org/I33814908"],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":{"value":0.20995798,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":"600","last_page":"602"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T14502","display_name":"High-Voltage Power Transmission Systems","score":0.4058000147342682,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T14502","display_name":"High-Voltage Power Transmission Systems","score":0.4058000147342682,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12692","display_name":"Magnetic Field Sensors Techniques","score":0.35740000009536743,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10972","display_name":"Power Systems Fault Detection","score":0.07119999825954437,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/high-voltage-current-transformers","display_name":"high-voltage current transformers","score":0.8560000061988831},{"id":"https://openalex.org/keywords/in-service-failure","display_name":"in-service failure","score":0.8610000014305115},{"id":"https://openalex.org/keywords/transformer-design","display_name":"transformer design","score":0.44200000166893005},{"id":"https://openalex.org/keywords/manitoba-hydro","display_name":"Manitoba Hydro","score":0.6809999942779541},{"id":"https://openalex.org/keywords/hvdc-transmission","display_name":"HVDC transmission","score":0.5860000252723694},{"id":"https://openalex.org/keywords/failure-investigation","display_name":"failure investigation","score":0.3880000114440918}],"concepts":[{"id":"https://openalex.org/C133770746","wikidata":"https://www.wikidata.org/wiki/Q856535","display_name":"Current transformer","level":4,"score":0.6274535655975342},{"id":"https://openalex.org/C66322947","wikidata":"https://www.wikidata.org/wiki/Q11658","display_name":"Transformer","level":3,"score":0.5851196646690369},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.5633575320243835},{"id":"https://openalex.org/C148043351","wikidata":"https://www.wikidata.org/wiki/Q4456944","display_name":"Current (fluid)","level":2,"score":0.5051661133766174},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.43068042397499084},{"id":"https://openalex.org/C2780378061","wikidata":"https://www.wikidata.org/wiki/Q25351891","display_name":"Service (business)","level":2,"score":0.4275243878364563},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.4097399115562439},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.38745468854904175},{"id":"https://openalex.org/C76155785","wikidata":"https://www.wikidata.org/wiki/Q418","display_name":"Telecommunications","level":1,"score":0.3790328800678253},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.2079947590827942},{"id":"https://openalex.org/C144133560","wikidata":"https://www.wikidata.org/wiki/Q4830453","display_name":"Business","level":0,"score":0.16883394122123718},{"id":"https://openalex.org/C162853370","wikidata":"https://www.wikidata.org/wiki/Q39809","display_name":"Marketing","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/icacact.2014.7223491","doi":"https://doi.org/10.1109/icacact.2014.7223491","is_oa":false,"landing_page_url":"https://doi.org/10.1109/icacact.2014.7223491","pdf_url":null,"source":{"id":"https://openalex.org/S7407086244","display_name":"IEEE Electrical Insulation Conference (EIC)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2015 IEEE Electrical Insulation Conference (EIC)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"display_name":"Industry, innovation and infrastructure","id":"https://metadata.un.org/sdg/9","score":0.651199996471405}],"study_designs":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":2,"referenced_works":["https://openalex.org/W2028865474","https://openalex.org/W2126035453"],"related_works":["https://openalex.org/W2164597557","https://openalex.org/W2054192519","https://openalex.org/W2368913927","https://openalex.org/W2392067943","https://openalex.org/W2378861720","https://openalex.org/W4252307204","https://openalex.org/W2351422791","https://openalex.org/W3048032311","https://openalex.org/W2388383810","https://openalex.org/W2393370854"],"abstract_inverted_index":{"At":[0],"Manitoba":[1],"Hydro":[2],"the":[3,51],"first":[4],"550":[5],"kV":[6],"current":[7],"transformers":[8],"were":[9],"placed":[10],"in":[11,13,19,31,38],"service":[12],"1980":[14],"followed":[15],"by":[16],"additional":[17],"units":[18],"1994":[20],"and":[21,41],"2014.":[22,42],"A":[23],"total":[24],"of":[25],"three":[26],"different":[27],"designs":[28],"are":[29],"now":[30],"service.":[32],"In-service":[33],"failures":[34],"or":[35],"troubles":[36],"occurred":[37],"1986,":[39],"2004":[40],"The":[43],"paper":[44],"summarizes":[45],"what":[46],"has":[47],"been":[48],"learned":[49],"from":[50],"investigations.":[52]},"counts_by_year":[],"updated_date":"2026-10-06T10:28:23.643775","created_date":"2016-06-24T00:00:00"}