{"id":"https://openalex.org/W22664005","doi":null,"title":"Implantable volume monitor and miniaturized stimulator dedicated to bladder control.","display_name":"Implantable volume monitor and miniaturized stimulator dedicated to bladder control.","alternate_titles":[],"publication_year":1997,"publication_date":"1997-03-01","ids":{"openalex":"https://openalex.org/W22664005","mag":"22664005","pmid":"https://pubmed.ncbi.nlm.nih.gov/9148710"},"language":"en","primary_location":{"id":"pmid:9148710","doi":null,"is_oa":false,"landing_page_url":"https://pubmed.ncbi.nlm.nih.gov/9148710","pdf_url":null,"source":{"id":"https://openalex.org/S4306525036","display_name":"PubMed","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I1299303238","host_organization_name":"National Institutes of Health","host_organization_lineage":["https://openalex.org/I1299303238"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Artificial organs","raw_type":"Journal Article"},"parent_works":[],"lineage":["https://openalex.org/W22664005"],"child_works_count":0,"type":"article","is_traditional":true,"indexed_in":["pubmed"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5082509767","display_name":"Mohamad Sawan","orcid":"https://orcid.org/0000-0002-4137-7272","observed_orcids":["https://orcid.org/0000-0002-4137-7272"]},"institutions":[{"id":"https://openalex.org/I45683168","display_name":"Polytechnique Montr\u00e9al","ror":"https://ror.org/05f8d4e86","country_code":"CA","type":"education","lineage":["https://openalex.org/I45683168"]}],"countries":["CA"],"is_corresponding":false,"raw_author_name":"M Sawan","raw_affiliation_strings":["Department of Electrical and Computer Engineering, Ecole Polytechnique de Montr\u00e9al, Qu\u00e9bec, Canada"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Electrical and Computer Engineering, Ecole Polytechnique de Montr\u00e9al, Qu\u00e9bec, Canada","institution_ids":["https://openalex.org/I45683168"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5043616116","display_name":"Karim Arabi","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"K Arabi","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"last","author":{"id":"https://openalex.org/A5059941118","display_name":"B. Provost","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"B Provost","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":1.6172,"has_fulltext":false,"cited_by_count":26,"citation_normalized_percentile":{"value":0.82080407,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":86,"max":95},"biblio":{"volume":"21","issue":"3","first_page":"219","last_page":"222"},"is_retracted":false,"is_pulled":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10279","display_name":"Urinary Bladder and Prostate Research","score":0.4672999978065491,"subfield":{"id":"https://openalex.org/subfields/2748","display_name":"Urology"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},"topics":[{"id":"https://openalex.org/T10279","display_name":"Urinary Bladder and Prostate Research","score":0.4672999978065491,"subfield":{"id":"https://openalex.org/subfields/2748","display_name":"Urology"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},{"id":"https://openalex.org/T11601","display_name":"Neuroscience and Neural Engineering","score":0.4602000117301941,"subfield":{"id":"https://openalex.org/subfields/2804","display_name":"Cellular and Molecular Neuroscience"},"field":{"id":"https://openalex.org/fields/28","display_name":"Neuroscience"},"domain":{"id":"https://openalex.org/domains/1","display_name":"Life Sciences"}},{"id":"https://openalex.org/T11778","display_name":"Electrical and Bioimpedance Tomography","score":0.011500000022351742,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/bladder-volume-monitoring","display_name":"bladder volume monitoring","score":0.8130000233650208},{"id":"https://openalex.org/keywords/neuromuscular-stimulation","display_name":"neuromuscular stimulation","score":0.9139999747276306},{"id":"https://openalex.org/keywords/spinal-cord-injury","display_name":"spinal cord injury","score":0.9010000228881836},{"id":"https://openalex.org/keywords/neurogenic-bladder","display_name":"neurogenic bladder","score":0.7739999890327454},{"id":"https://openalex.org/keywords/optical-communication-links","display_name":"optical communication links","score":0.7630000114440918}],"concepts":[{"id":"https://openalex.org/C197424946","wikidata":"https://www.wikidata.org/wiki/Q1165717","display_name":"Waveform","level":3,"score":0.559363603591919},{"id":"https://openalex.org/C203479927","wikidata":"https://www.wikidata.org/wiki/Q5165939","display_name":"Controller (irrigation)","level":2,"score":0.5373420119285583},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.5086827874183655},{"id":"https://openalex.org/C9390403","wikidata":"https://www.wikidata.org/wiki/Q3966","display_name":"Computer hardware","level":1,"score":0.5039436221122742},{"id":"https://openalex.org/C2779843651","wikidata":"https://www.wikidata.org/wiki/Q7390335","display_name":"SIGNAL (programming language)","level":2,"score":0.48975038528442383},{"id":"https://openalex.org/C20556612","wikidata":"https://www.wikidata.org/wiki/Q4469374","display_name":"Volume (thermodynamics)","level":2,"score":0.45039764046669006},{"id":"https://openalex.org/C136229726","wikidata":"https://www.wikidata.org/wiki/Q327092","display_name":"Biomedical engineering","level":1,"score":0.44772815704345703},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.43230515718460083},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.42491763830184937},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.29477056860923767},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.2620362937450409},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.09761127829551697},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C199360897","wikidata":"https://www.wikidata.org/wiki/Q9143","display_name":"Programming language","level":1,"score":0.0},{"id":"https://openalex.org/C6557445","wikidata":"https://www.wikidata.org/wiki/Q173113","display_name":"Agronomy","level":1,"score":0.0},{"id":"https://openalex.org/C86803240","wikidata":"https://www.wikidata.org/wiki/Q420","display_name":"Biology","level":0,"score":0.0}],"mesh":[{"descriptor_ui":"D001743","descriptor_name":"Urinary Bladder","qualifier_ui":"Q000502","qualifier_name":"physiology","is_major_topic":true},{"descriptor_ui":"D003198","descriptor_name":"Computer Simulation","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D004599","descriptor_name":"Electric Stimulation Therapy","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":true},{"descriptor_ui":"D006801","descriptor_name":"Humans","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D011786","descriptor_name":"Quality Control","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D013119","descriptor_name":"Spinal Cord Injuries","qualifier_ui":"Q000150","qualifier_name":"complications","is_major_topic":false},{"descriptor_ui":"D013119","descriptor_name":"Spinal Cord Injuries","qualifier_ui":"Q000503","qualifier_name":"physiopathology","is_major_topic":false},{"descriptor_ui":"D013119","descriptor_name":"Spinal Cord Injuries","qualifier_ui":"Q000534","qualifier_name":"rehabilitation","is_major_topic":true},{"descriptor_ui":"D013686","descriptor_name":"Telemetry","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D014057","descriptor_name":"Tomography, X-Ray Computed","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D014549","descriptor_name":"Urinary Incontinence","qualifier_ui":"Q000628","qualifier_name":"therapy","is_major_topic":true}],"locations_count":3,"locations":[{"id":"pmid:9148710","doi":null,"is_oa":false,"landing_page_url":"https://pubmed.ncbi.nlm.nih.gov/9148710","pdf_url":null,"source":{"id":"https://openalex.org/S4306525036","display_name":"PubMed","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I1299303238","host_organization_name":"National Institutes of Health","host_organization_lineage":["https://openalex.org/I1299303238"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Artificial organs","raw_type":"Journal Article"},{"id":"pmh:oai:publications.polymtl.ca:30069","doi":null,"is_oa":false,"landing_page_url":"https://publications.polymtl.ca/30069/","pdf_url":null,"source":{"id":"https://openalex.org/S4306401013","display_name":"PolyPublie (\u00c9cole Polytechnique de Montr\u00e9al)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I45683168","host_organization_name":"Polytechnique Montr\u00e9al","host_organization_lineage":["https://openalex.org/I45683168"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"Sawan, M., Arabi, K., & Provost, B. (1997). Implantable volume monitor and miniaturized stimulator dedicated to bladder control. Artificial Organs, 21(3), 219-222.","raw_type":"http://purl.org/coar/resource_type/c_6501"},{"id":"mag:22664005","doi":null,"is_oa":false,"landing_page_url":"https://pubmed.ncbi.nlm.nih.gov/9148710","pdf_url":null,"source":{"id":"https://openalex.org/S4306525036","display_name":"PubMed","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I1299303238","host_organization_name":"National Institutes of Health","host_organization_lineage":["https://openalex.org/I1299303238"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false,"raw_source_name":"PubMed","raw_type":null}],"best_oa_location":null,"sustainable_development_goals":[{"score":0.8048999905586243,"display_name":"Good health and well-being","id":"https://metadata.un.org/sdg/3"}],"study_designs":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":10,"referenced_works":["https://openalex.org/W157258055","https://openalex.org/W1963545439","https://openalex.org/W1996904669","https://openalex.org/W2014088607","https://openalex.org/W2031915073","https://openalex.org/W2057932327","https://openalex.org/W2105869309","https://openalex.org/W2113041255","https://openalex.org/W2148913966","https://openalex.org/W2162322495"],"related_works":["https://openalex.org/W2086800856","https://openalex.org/W1513606259","https://openalex.org/W2106572546","https://openalex.org/W2400807962","https://openalex.org/W2120674009","https://openalex.org/W2165718482","https://openalex.org/W2160196495","https://openalex.org/W2050113720","https://openalex.org/W1976536104","https://openalex.org/W1890253689"],"abstract_inverted_index":{"This":[0],"paper":[1],"describes":[2],"a":[3,16,25,33,65,85,108],"new":[4],"miniaturized":[5,28],"implantable":[6,80],"bladder":[7,52,73],"controller":[8],"that":[9],"is":[10,46,82,104],"composed":[11],"of":[12,111,126],"4":[13],"main":[14],"parts:":[15],"volume":[17,130],"monitoring":[18,131],"device":[19],"based":[20],"on":[21],"the":[22,72,124,127,134],"tomography":[23],"approach,":[24],"fully":[26],"programmable":[27],"central":[29],"processor":[30],"and":[31,36,39,55,90,129],"stimulator,":[32],"bidirectional":[34],"data":[35],"power":[37],"link,":[38],"an":[40,120],"external":[41,135],"controller.":[42,136],"The":[43,62,79,102],"proposed":[44],"system":[45,63],"intended":[47],"to":[48,57,70,94,106,133],"restore":[49],"both":[50],"normal":[51],"functions":[53,74],"(retention":[54],"voiding)":[56],"spinal":[58],"cord":[59],"injured":[60],"patients.":[61],"contains":[64],"mixed-signal":[66],"(analog/digital)":[67],"feedback":[68],"loop":[69],"command":[71],"through":[75],"neuromuscular":[76],"stimulation":[77,112,116],"techniques.":[78],"circuitry":[81],"powered":[83],"by":[84],"single":[86],"encoded":[87],"radiofrequency":[88],"carried":[89],"may":[91],"have":[92],"up":[93],"8":[95],"independently":[96],"controlled":[97],"monopolar":[98],"(4":[99],"bipolar)":[100],"channels.":[101],"microstimulator":[103],"able":[105],"generate":[107],"wide":[109],"range":[110],"patterns,":[113],"including":[114],"selective":[115],"waveforms.":[117],"In":[118],"addition,":[119],"optical":[121],"link":[122],"transmits":[123],"state":[125],"implant":[128],"results":[132]},"cited_by_api_url":"https://api.openalex.org/works?filter=cites:W22664005","counts_by_year":[{"year":2020,"cited_by_count":1},{"year":2014,"cited_by_count":2},{"year":2013,"cited_by_count":1}],"updated_date":"2026-11-16T12:05:36.265796","created_date":"2016-06-24T00:00:00"}
