{"id":"https://openalex.org/W2245877339","doi":"https://doi.org/10.1093/oxfordjournals.rpd.a082414","title":"Influence of Ventilation Rate on Indoor Radon Concentration in a Test Chamber","display_name":"Influence of Ventilation Rate on Indoor Radon Concentration in a Test Chamber","alternate_titles":[],"publication_year":1994,"publication_date":"1994-12-01","ids":{"openalex":"https://openalex.org/W2245877339","doi":"https://doi.org/10.1093/oxfordjournals.rpd.a082414","mag":"2245877339"},"language":"en","primary_location":{"id":"doi:10.1093/oxfordjournals.rpd.a082414","doi":"https://doi.org/10.1093/oxfordjournals.rpd.a082414","is_oa":false,"landing_page_url":"https://doi.org/10.1093/oxfordjournals.rpd.a082414","pdf_url":null,"source":{"id":"https://openalex.org/S201595455","display_name":"Radiation Protection Dosimetry","issn_l":"0144-8420","issn":["0144-8420","1742-3406"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["cwts-core","dongbi-c","doyens","jufo-1","ki-jl-1","medline","norway-1","poland-40","russia-white-list-3","vabb-shw"],"host_organization":"https://openalex.org/P4310311648","host_organization_name":"Oxford University Press","host_organization_lineage":["https://openalex.org/P4310311648","https://openalex.org/P4310311647"],"host_organization_lineage_names":["Oxford University Press","University of Oxford"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Radiation Protection Dosimetry","raw_type":"journal-article"},"parent_works":[],"lineage":["https://openalex.org/W2245877339"],"child_works_count":0,"pull_notice_works":[],"type":"article","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5064789497","display_name":"D. Capra","type":null,"orcid":null,"observed_orcids":[]},"acted_on_behalf_of":[],"institutions":[],"countries":[],"is_corresponding":false,"contributor_roles":[],"raw_author_name":"D. Capra","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"middle","author":{"id":"https://openalex.org/A5028585885","display_name":"Camillo Silibello","type":null,"orcid":"https://orcid.org/0000-0002-0400-6755","observed_orcids":["https://orcid.org/0000-0002-0400-6755"]},"acted_on_behalf_of":[],"institutions":[],"countries":[],"is_corresponding":false,"contributor_roles":[],"raw_author_name":"C. Silibello","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"last","author":{"id":"https://openalex.org/A5082584939","display_name":"Giulio Queirazza","type":null,"orcid":null,"observed_orcids":[]},"acted_on_behalf_of":[],"institutions":[],"countries":[],"is_corresponding":false,"contributor_roles":[],"raw_author_name":"G. Queirazza","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]}],"institutions":[],"countries_distinct_count":0,"institutions_distinct_count":0,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":{"value":4533,"currency":"USD","value_usd":4533},"apc_paid":null,"fwci":0.4345,"has_fulltext":false,"cited_by_count":6,"reviewed_by_count":0,"citation_normalized_percentile":{"value":0.48659794,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":86,"max":92},"biblio":{"volume":"56","issue":"1-4","first_page":"15","last_page":"18"},"is_retracted":false,"is_pulled":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10946","display_name":"Radioactivity and Radon Measurements","score":1.0,"subfield":{"id":"https://openalex.org/subfields/3108","display_name":"Radiation"},"field":{"id":"https://openalex.org/fields/31","display_name":"Physics and Astronomy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10946","display_name":"Radioactivity and Radon Measurements","score":1.0,"subfield":{"id":"https://openalex.org/subfields/3108","display_name":"Radiation"},"field":{"id":"https://openalex.org/fields/31","display_name":"Physics and Astronomy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11002","display_name":"Indoor Air Quality and Microbial Exposure","score":9.999999747378752e-05,"subfield":{"id":"https://openalex.org/subfields/2307","display_name":"Health, Toxicology and Mutagenesis"},"field":{"id":"https://openalex.org/fields/23","display_name":"Environmental Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11089","display_name":"Radioactive contamination and transfer","score":0.0,"subfield":{"id":"https://openalex.org/subfields/2310","display_name":"Pollution"},"field":{"id":"https://openalex.org/fields/23","display_name":"Environmental Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/indoor-radon-concentration","display_name":"indoor radon concentration","score":0.9480000138282776},{"id":"https://openalex.org/keywords/ventilation-rate","display_name":"ventilation rate","score":0.9810000061988831},{"id":"https://openalex.org/keywords/radon-sources","display_name":"radon sources","score":0.8159999847412109},{"id":"https://openalex.org/keywords/test-chamber","display_name":"test chamber","score":0.7730000019073486},{"id":"https://openalex.org/keywords/building-materials","display_name":"building materials","score":0.6489999890327454},{"id":"https://openalex.org/keywords/ambient-air","display_name":"ambient air","score":0.7279999852180481},{"id":"https://openalex.org/keywords/soil-radon","display_name":"soil radon","score":0.6200000047683716},{"id":"https://openalex.org/keywords/differential-pressure","display_name":"pressure difference","score":0.7639999985694885},{"id":"https://openalex.org/keywords/radon-mitigation","display_name":"radon mitigation","score":0.7599999904632568},{"id":"https://openalex.org/keywords/mathematical-modeling","display_name":"mathematical modeling","score":0.6520000100135803}],"concepts":[{"id":"https://openalex.org/C545943180","wikidata":"https://www.wikidata.org/wiki/Q1133","display_name":"Radon","level":2,"score":0.8352383375167847},{"id":"https://openalex.org/C39432304","wikidata":"https://www.wikidata.org/wiki/Q188847","display_name":"Environmental science","level":0,"score":0.753497838973999},{"id":"https://openalex.org/C116067010","wikidata":"https://www.wikidata.org/wiki/Q4698686","display_name":"Airflow","level":2,"score":0.7187185883522034},{"id":"https://openalex.org/C200457457","wikidata":"https://www.wikidata.org/wiki/Q584049","display_name":"Ventilation (architecture)","level":2,"score":0.7134243845939636},{"id":"https://openalex.org/C2993878198","wikidata":"https://www.wikidata.org/wiki/Q905504","display_name":"Indoor air","level":2,"score":0.5880568027496338},{"id":"https://openalex.org/C2776132308","wikidata":"https://www.wikidata.org/wiki/Q11070850","display_name":"Inflow","level":2,"score":0.5739521980285645},{"id":"https://openalex.org/C2984663118","wikidata":"https://www.wikidata.org/wiki/Q7424019","display_name":"Differential pressure","level":2,"score":0.5103723406791687},{"id":"https://openalex.org/C65469","wikidata":"https://www.wikidata.org/wiki/Q905504","display_name":"Indoor air quality","level":2,"score":0.4772886335849762},{"id":"https://openalex.org/C87717796","wikidata":"https://www.wikidata.org/wiki/Q146326","display_name":"Environmental engineering","level":1,"score":0.40233686566352844},{"id":"https://openalex.org/C153294291","wikidata":"https://www.wikidata.org/wiki/Q25261","display_name":"Meteorology","level":1,"score":0.29440295696258545},{"id":"https://openalex.org/C57879066","wikidata":"https://www.wikidata.org/wiki/Q41217","display_name":"Mechanics","level":1,"score":0.18828359246253967},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.12222576141357422},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.08493614196777344},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0}],"mesh":[],"locations_count":2,"locations":[{"id":"doi:10.1093/oxfordjournals.rpd.a082414","doi":"https://doi.org/10.1093/oxfordjournals.rpd.a082414","is_oa":false,"landing_page_url":"https://doi.org/10.1093/oxfordjournals.rpd.a082414","pdf_url":null,"source":{"id":"https://openalex.org/S201595455","display_name":"Radiation Protection Dosimetry","issn_l":"0144-8420","issn":["0144-8420","1742-3406"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["cwts-core","dongbi-c","doyens","jufo-1","ki-jl-1","medline","norway-1","poland-40","russia-white-list-3","vabb-shw"],"host_organization":"https://openalex.org/P4310311648","host_organization_name":"Oxford University Press","host_organization_lineage":["https://openalex.org/P4310311648","https://openalex.org/P4310311647"],"host_organization_lineage_names":["Oxford University Press","University of Oxford"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Radiation Protection Dosimetry","raw_type":"journal-article"},{"id":"doi:10.1093/rpd/56.1-4.15","doi":"https://doi.org/10.1093/rpd/56.1-4.15","is_oa":false,"landing_page_url":"http://doi.org/10.1093/rpd/56.1-4.15","pdf_url":null,"source":{"id":"https://openalex.org/S201595455","display_name":"Radiation Protection Dosimetry","issn_l":"0144-8420","issn":["0144-8420","1742-3406"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["cwts-core","dongbi-c","doyens","jufo-1","ki-jl-1","medline","norway-1","poland-40","russia-white-list-3","vabb-shw"],"host_organization":"https://openalex.org/P4310311648","host_organization_name":"Oxford University Press","host_organization_lineage":["https://openalex.org/P4310311648","https://openalex.org/P4310311647"],"host_organization_lineage_names":["Oxford University Press","University of Oxford"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Radiation Protection Dosimetry","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[],"study_designs":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":0,"referenced_works":[],"related_works":["https://openalex.org/W2002373417","https://openalex.org/W1409657797","https://openalex.org/W2077868753","https://openalex.org/W2048119990","https://openalex.org/W1969098474","https://openalex.org/W7025567323","https://openalex.org/W2439010950","https://openalex.org/W2473207705","https://openalex.org/W17675664","https://openalex.org/W3172551625"],"abstract_inverted_index":{"A":[0],"methodological":[1],"approach":[2],"is":[3],"proposed":[4],"in":[5,22,83],"order":[6],"to":[7,19,31,108],"identify":[8],"the":[9,15,36,39,63,67,86,109,116,120],"sources":[10],"of":[11,28,38,69,94,102,111],"indoor":[12,112],"radon":[13,70,90],"and":[14,46,56,74,79,99],"proper":[16],"remedial":[17],"actions":[18],"be":[20],"undertaken":[21],"highly":[23],"contaminated":[24],"houses.":[25],"The":[26,81],"application":[27],"this":[29],"methodology":[30],"a":[32,100],"test":[33,64],"chamber":[34,65],"allows":[35],"evaluation":[37],"following":[40,87],"sources:":[41],"building":[42],"materials,":[43],"outdoor":[44,97],"air":[45,98],"underlying":[47,105],"soil.":[48],"Estimates":[49],"are":[50],"performed":[51],"by":[52],"both":[53],"experimental":[54],"techniques":[55],"mathematical":[57],"modelling.":[58],"Measurements":[59],"carried":[60],"out":[61],"inside":[62],"indicate":[66],"dependence":[68],"concentration":[71],"on":[72,89],"ventilation":[73,84],"differential":[75],"pressure":[76,113],"between":[77],"indoors":[78],"outdoors.":[80],"increase":[82,93],"induces":[85],"effects":[88],"entry:":[91],"an":[92],"entrance":[95],"from":[96,104,119],"diminution":[101],"inflow":[103],"crawlspace":[106],"due":[107],"rise":[110],"that":[114],"inhibits":[115],"upward":[117],"airflow":[118],"crawlspace.":[121]},"cited_by_api_url":"https://api.openalex.org/works?filter=cites:W2245877339","counts_by_year":[{"year":2022,"cited_by_count":1},{"year":2018,"cited_by_count":1},{"year":2013,"cited_by_count":1}],"updated_date":"2026-11-25T09:40:18.809321","created_date":"2016-06-24T00:00:00"}
