{"id":"https://openalex.org/W2240297486","doi":null,"title":"Hydraulic Modelling of Cable-in-Conduit Conductors (CICC): CFD Approach","display_name":"Hydraulic Modelling of Cable-in-Conduit Conductors (CICC): CFD Approach","publication_year":2012,"publication_date":"2012-01-01","ids":{"openalex":"https://openalex.org/W2240297486","mag":"2240297486"},"language":"fr","primary_location":{"id":"mag:2240297486","doi":null,"is_oa":false,"landing_page_url":"http://www.indianjournals.com/ijor.aspx?target=ijor:ijc&volume=38&issue=1to4&article=003","pdf_url":null,"source":{"id":"https://openalex.org/S2764674751","display_name":"Indian Journal of Cryogenics","issn_l":"0379-0479","issn":["0379-0479","2349-2120"],"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"journal"},"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false,"raw_source_name":"Indian Journal of Cryogenics","raw_type":null},"parent_works":[],"lineage":["https://openalex.org/W2240297486"],"child_works_count":0,"type":"article","is_traditional":true,"indexed_in":[],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5089002479","display_name":"D. Raja Sekhar","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"D. Raja Sekhar","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"middle","author":{"id":"https://openalex.org/A5103420019","display_name":"Vutukuru Vasudeva Rao","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"V.V. Rao","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"middle","author":{"id":"https://openalex.org/A5110571815","display_name":"B. Sarkar","orcid":"https://orcid.org/0000-0002-9674-7381","observed_orcids":["https://orcid.org/0000-0002-9674-7381"]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"B. Sarkar","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"last","author":{"id":"https://openalex.org/A5091744203","display_name":"Renu Bahl","orcid":"https://orcid.org/0009-0008-7956-8147","observed_orcids":["https://orcid.org/0009-0008-7956-8147"]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Renu Bahl","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]}],"institutions":[],"countries_distinct_count":0,"institutions_distinct_count":0,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":2,"citation_normalized_percentile":{"value":0.0,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":93,"max":95},"biblio":{"volume":"38","issue":null,"first_page":"13","last_page":"18"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11808","display_name":"Superconducting Materials and Applications","score":0.9868000149726868,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11808","display_name":"Superconducting Materials and Applications","score":0.9868000149726868,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12567","display_name":"Heat transfer and supercritical fluids","score":0.008700000122189522,"subfield":{"id":"https://openalex.org/subfields/2206","display_name":"Computational Mechanics"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12560","display_name":"Nuclear Engineering Thermal-Hydraulics","score":0.0013000000035390258,"subfield":{"id":"https://openalex.org/subfields/2104","display_name":"Nuclear Energy and Engineering"},"field":{"id":"https://openalex.org/fields/21","display_name":"Energy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/cable-in-conduit-conductors","display_name":"cable-in-conduit conductors","score":0.9779999852180481},{"id":"https://openalex.org/keywords/superconducting-cables","display_name":"superconducting cables","score":0.8080000281333923},{"id":"https://openalex.org/keywords/pressure-drop","display_name":"pressure drop","score":0.8650000095367432},{"id":"https://openalex.org/keywords/friction-factor","display_name":"friction factor","score":0.996999979019165},{"id":"https://openalex.org/keywords/supercritical-helium","display_name":"supercritical helium","score":0.7710000276565552},{"id":"https://openalex.org/keywords/coolant-flow","display_name":"coolant flow","score":0.7009999752044678},{"id":"https://openalex.org/keywords/mass-flow-rate","display_name":"mass flow rate","score":0.8270000219345093},{"id":"https://openalex.org/keywords/heat-transfer","display_name":"heat transfer","score":0.6359999775886536},{"id":"https://openalex.org/keywords/pumping-power","display_name":"pumping power","score":0.9399999976158142},{"id":"https://openalex.org/keywords/hydraulic-modeling","display_name":"hydraulic modeling","score":0.48399999737739563}],"concepts":[{"id":"https://openalex.org/C114088122","wikidata":"https://www.wikidata.org/wiki/Q1261069","display_name":"Pressure drop","level":2,"score":0.8838346600532532},{"id":"https://openalex.org/C2780411076","wikidata":"https://www.wikidata.org/wiki/Q5462653","display_name":"Fluent","level":3,"score":0.730128288269043},{"id":"https://openalex.org/C2776757364","wikidata":"https://www.wikidata.org/wiki/Q208544","display_name":"Gambit","level":4,"score":0.7041865587234497},{"id":"https://openalex.org/C89836073","wikidata":"https://www.wikidata.org/wiki/Q1719631","display_name":"Electrical conduit","level":2,"score":0.688057541847229},{"id":"https://openalex.org/C75892298","wikidata":"https://www.wikidata.org/wiki/Q1366187","display_name":"Mass flow rate","level":2,"score":0.6600608825683594},{"id":"https://openalex.org/C57879066","wikidata":"https://www.wikidata.org/wiki/Q41217","display_name":"Mechanics","level":1,"score":0.5853342413902283},{"id":"https://openalex.org/C91914117","wikidata":"https://www.wikidata.org/wiki/Q1056832","display_name":"Coolant","level":2,"score":0.5625365376472473},{"id":"https://openalex.org/C172120300","wikidata":"https://www.wikidata.org/wiki/Q1134348","display_name":"Volumetric flow rate","level":2,"score":0.47903338074684143},{"id":"https://openalex.org/C1633027","wikidata":"https://www.wikidata.org/wiki/Q815820","display_name":"Computational fluid dynamics","level":2,"score":0.4606781601905823},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.4565233588218689},{"id":"https://openalex.org/C192562407","wikidata":"https://www.wikidata.org/wiki/Q228736","display_name":"Materials science","level":0,"score":0.45359817147254944},{"id":"https://openalex.org/C116915560","wikidata":"https://www.wikidata.org/wiki/Q83504","display_name":"Nuclear engineering","level":1,"score":0.37874582409858704},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.3100452423095703},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.18893760442733765}],"mesh":[],"locations_count":1,"locations":[{"id":"mag:2240297486","doi":null,"is_oa":false,"landing_page_url":"http://www.indianjournals.com/ijor.aspx?target=ijor:ijc&volume=38&issue=1to4&article=003","pdf_url":null,"source":{"id":"https://openalex.org/S2764674751","display_name":"Indian Journal of Cryogenics","issn_l":"0379-0479","issn":["0379-0479","2349-2120"],"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"journal"},"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false,"raw_source_name":"Indian Journal of Cryogenics","raw_type":null}],"best_oa_location":null,"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/9","display_name":"Industry, innovation and infrastructure","score":0.4943999946117401}],"study_designs":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":0,"referenced_works":[],"related_works":["https://openalex.org/W2130462227","https://openalex.org/W2082889770","https://openalex.org/W2128584007","https://openalex.org/W7133555209","https://openalex.org/W3111954816","https://openalex.org/W2119200103","https://openalex.org/W2114413266","https://openalex.org/W2048108087","https://openalex.org/W2168523805","https://openalex.org/W3180518162"],"abstract_inverted_index":{"A":[0],"practical":[1],"design":[2,34],"of":[3,13,35,76],"cable-in-conduit":[4],"conductor":[5],"(GIGG)":[6],"cables,":[7],"for":[8,37,70,108],"different":[9],"applications,":[10],"involves":[11],"calculation":[12],"pressure":[14,71,82,125,138,153],"drop,":[15],"friction":[16],"factor":[17,130],"and":[18,39,92],"heat":[19],"transfer.":[20],"The":[21,74,87,97],"flow":[22,78,118],"analysis":[23,43],"is":[24,68,90,112,134],"expected":[25],"to":[26,32,50,101,150],"address":[27],"the":[28,33,46,52,58,81,116,121,124,132,137,147,152],"hydraulic":[29],"issues":[30],"relevant":[31],"GICCs":[36],"safe":[38],"optimum":[40],"operation.":[41],"Flow":[42],"also":[44,145],"yields":[45],"pumping":[47],"power":[48],"required":[49],"circulate":[51],"coolant":[53],"(Supercritical":[54],"Helium":[55],"(SHe)).":[56],"In":[57],"present":[59],"work,":[60],"a":[61,104],"dual":[62],"channel":[63],"GIGG":[64,133],"with":[65],"central":[66],"spiral":[67],"considered":[69],"drop":[72,83,126,139],"analysis.":[73,110],"effect":[75],"mass":[77,117],"rate":[79,119],"on":[80],"has":[84],"been":[85],"investigated.":[86],"computational":[88],"domain":[89],"built":[91],"meshed":[93],"in":[94,131],"GAMBIT":[95],"2.0.":[96],"mesh":[98],"was":[99],"exported":[100],"FLUENT":[102],"6.3,":[103],"commercial":[105],"GFO":[106,148],"code,":[107],"further":[109],"It":[111],"observed":[113],"that":[114],"as":[115],"through":[120],"conduit":[122],"increases,":[123],"increases":[127],"appreciably.":[128],"Friction":[129],"calculated":[135],"from":[136,141],"obtained":[140],"FLUENT.":[142],"This":[143],"paper":[144],"presents":[146],"methodology":[149],"find":[151],"drop.":[154]},"counts_by_year":[{"year":2021,"cited_by_count":2}],"updated_date":"2026-09-29T14:09:16.559479","created_date":"2016-06-24T00:00:00"}
