{"id":"https://openalex.org/W2198294775","doi":null,"title":"Arithmetic and Logical Models of Stranded Transmission Line Conductors for Voltage and Voltage-Drop Analysis","display_name":"Arithmetic and Logical Models of Stranded Transmission Line Conductors for Voltage and Voltage-Drop Analysis","publication_year":2015,"publication_date":"2015-11-03","ids":{"openalex":"https://openalex.org/W2198294775","mag":"2198294775"},"language":"en","primary_location":{"id":"pmh:oai:CiteSeerX.psu:10.1.1.680.9697","doi":null,"is_oa":false,"landing_page_url":"http://citeseerx.ist.psu.edu/viewdoc/summary?doi=10.1.1.680.9697","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"http://www.issr-journals.org/links/papers.php?application%3Dpdf%26article%3DIJISR-14-189-03%26journal%3Dijisr","raw_type":"text"},"volume":null,"type":"article","indexed_in":[],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5021594495","display_name":"Abdul Rasak Zubair","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I181631907","display_name":"University of Ibadan","ror":"https://ror.org/03wx2rr30","country_code":"NG","type":"education","lineage":["https://openalex.org/I181631907"]}],"countries":["NG"],"is_corresponding":false,"raw_author_name":"Abdul Rasak Zubair","raw_affiliation_strings":["DEPARTMENT OF ELECTRICAL/ELECTRONIC ENGINEERING, UNIVERSITY OF IBADAN, IBADAN. OYO STATE. NIGERIA"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"DEPARTMENT OF ELECTRICAL/ELECTRONIC ENGINEERING, UNIVERSITY OF IBADAN, IBADAN. OYO STATE. NIGERIA","institution_ids":["https://openalex.org/I181631907"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5032945722","display_name":"Adeboye Olatunbosun","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I181631907","display_name":"University of Ibadan","ror":"https://ror.org/03wx2rr30","country_code":"NG","type":"education","lineage":["https://openalex.org/I181631907"]}],"countries":["NG"],"is_corresponding":false,"raw_author_name":"Adeboye Olatunbosun","raw_affiliation_strings":["DEPARTMENT OF ELECTRICAL/ELECTRONIC ENGINEERING, UNIVERSITY OF IBADAN, IBADAN. OYO STATE. NIGERIA"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"DEPARTMENT OF ELECTRICAL/ELECTRONIC ENGINEERING, UNIVERSITY OF IBADAN, IBADAN. OYO STATE. NIGERIA","institution_ids":["https://openalex.org/I181631907"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":["https://openalex.org/I181631907"],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":1,"citation_normalized_percentile":{"value":0.08650865,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":90,"max":94},"biblio":{"volume":null,"issue":null,"first_page":null,"last_page":null},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T14502","display_name":"High-Voltage Power Transmission Systems","score":0.9965999722480774,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T14502","display_name":"High-Voltage Power Transmission Systems","score":0.9965999722480774,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12804","display_name":"Thermal Analysis in Power Transmission","score":0.0027000000700354576,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10511","display_name":"High voltage insulation and dielectric phenomena","score":9.999999747378752e-05,"subfield":{"id":"https://openalex.org/subfields/2505","display_name":"Materials Chemistry"},"field":{"id":"https://openalex.org/fields/25","display_name":"Materials Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/stranded-conductors","display_name":"stranded conductors","score":0.9449999928474426},{"id":"https://openalex.org/keywords/transmission-lines","display_name":"transmission lines","score":0.7319999933242798},{"id":"https://openalex.org/keywords/voltage-drop","display_name":"voltage drop","score":0.6489999890327454},{"id":"https://openalex.org/keywords/skin-effect","display_name":"skin effect","score":0.625},{"id":"https://openalex.org/keywords/corona","display_name":"corona","score":0.6830000281333923},{"id":"https://openalex.org/keywords/inductance-and-capacitance","display_name":"inductance and capacitance","score":0.8619999885559082}],"concepts":[{"id":"https://openalex.org/C33441834","wikidata":"https://www.wikidata.org/wiki/Q693004","display_name":"Transmission line","level":2,"score":0.6748834252357483},{"id":"https://openalex.org/C202374169","wikidata":"https://www.wikidata.org/wiki/Q124291","display_name":"Electrical conductor","level":2,"score":0.6439619064331055},{"id":"https://openalex.org/C34800285","wikidata":"https://www.wikidata.org/wiki/Q5159395","display_name":"Conductor","level":2,"score":0.6284724473953247},{"id":"https://openalex.org/C29210110","wikidata":"https://www.wikidata.org/wiki/Q177897","display_name":"Inductance","level":3,"score":0.5944486856460571},{"id":"https://openalex.org/C82178898","wikidata":"https://www.wikidata.org/wiki/Q166839","display_name":"Voltage drop","level":3,"score":0.5913713574409485},{"id":"https://openalex.org/C140311924","wikidata":"https://www.wikidata.org/wiki/Q200928","display_name":"Electric power transmission","level":2,"score":0.586004912853241},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.5225764513015747},{"id":"https://openalex.org/C198352243","wikidata":"https://www.wikidata.org/wiki/Q37105","display_name":"Line (geometry)","level":2,"score":0.5160581469535828},{"id":"https://openalex.org/C30066665","wikidata":"https://www.wikidata.org/wiki/Q164399","display_name":"Capacitance","level":3,"score":0.46753546595573425},{"id":"https://openalex.org/C28719098","wikidata":"https://www.wikidata.org/wiki/Q44946","display_name":"Point (geometry)","level":2,"score":0.43903297185897827},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.4296833872795105},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.31835269927978516},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.3142969310283661},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.24283581972122192},{"id":"https://openalex.org/C2524010","wikidata":"https://www.wikidata.org/wiki/Q8087","display_name":"Geometry","level":1,"score":0.23530858755111694},{"id":"https://openalex.org/C17525397","wikidata":"https://www.wikidata.org/wiki/Q176140","display_name":"Electrode","level":2,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"pmh:oai:CiteSeerX.psu:10.1.1.680.9697","doi":null,"is_oa":false,"landing_page_url":"http://citeseerx.ist.psu.edu/viewdoc/summary?doi=10.1.1.680.9697","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"http://www.issr-journals.org/links/papers.php?application%3Dpdf%26article%3DIJISR-14-189-03%26journal%3Dijisr","raw_type":"text"}],"best_oa_location":null,"sustainable_development_goals":[{"display_name":"Industry, innovation and infrastructure","score":0.6773999929428101,"id":"https://metadata.un.org/sdg/9"}],"sustainable_development_goals_aurora":[{"display_name":"Affordable and clean energy","score":0.8899999856948853,"id":"https://metadata.un.org/sdg/7"}],"study_designs":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":9,"referenced_works":["https://openalex.org/W1984526534","https://openalex.org/W2087713543","https://openalex.org/W2093558627","https://openalex.org/W2094722317","https://openalex.org/W2098557532","https://openalex.org/W2112952761","https://openalex.org/W2136004825","https://openalex.org/W2321752882","https://openalex.org/W2543620628"],"related_works":["https://openalex.org/W2699321289","https://openalex.org/W2564755123","https://openalex.org/W2079130596","https://openalex.org/W2112952761","https://openalex.org/W2090037670","https://openalex.org/W2039568858","https://openalex.org/W1569297369","https://openalex.org/W3150803506","https://openalex.org/W2770160573","https://openalex.org/W2249187501","https://openalex.org/W2362308018","https://openalex.org/W2828019255","https://openalex.org/W2938959807","https://openalex.org/W1996123616","https://openalex.org/W2835575187","https://openalex.org/W2550871529","https://openalex.org/W2926754747","https://openalex.org/W2829353291","https://openalex.org/W2867109968","https://openalex.org/W2062863710"],"abstract_inverted_index":{"ABSTRACT:":[0],"Transmission":[1,43],"lines":[2],"are":[3,92,106],"used":[4],"for":[5,64],"transportation":[6],"of":[7,12,17,38,40,58,76,83,102,104,121,123],"energy":[8],"from":[9],"the":[10,15,36,53,59,99,114],"point":[11,16],"generation":[13],"to":[14,72],"usage.":[18],"A":[19],"transmission":[20],"line":[21,31,44],"may":[22],"be":[23],"single-core":[24],"conductor":[25],"or":[26],"stranded":[27,90,124],"conductor.":[28],"Stranding":[29],"reduces":[30],"reactance,":[32],"skin":[33],"effect":[34],"and":[35,49,66,80,87,118],"tendency":[37],"occurrence":[39],"corona":[41],"effect.":[42],"parameters":[45],"such":[46],"as":[47],"inductance":[48],"capacitance":[50],"depend":[51],"on":[52],"geometric":[54],"mean":[55],"radius":[56],"(GMR)":[57],"line.":[60],"GMR":[61,122],"is":[62,70],"essential":[63],"Voltage":[65],"Voltage-Drop":[67],"analysis":[68],"which":[69,96,111],"necessary":[71],"ensure":[73],"save":[74],"operation":[75],"power":[77],"system.":[78],"Arithmetic":[79],"logical":[81],"models":[82,95],"triangular,":[84],"hexagonal,":[85],"circular":[86],"sector":[88],"shaped":[89],"conductors":[91],"presented.":[93],"The":[94],"accurately":[97],"predict":[98],"Cartesian":[100],"coordinates":[101],"centers":[103],"strands":[105],"coded":[107],"into":[108],"computer":[109],"programs":[110],"facilitate":[112],"both":[113],"accurate":[115,119],"graphical":[116],"drawing":[117],"computation":[120],"conductors.":[125]},"counts_by_year":[{"year":2025,"cited_by_count":1}],"updated_date":"2026-10-16T09:59:22.235173","created_date":"2025-10-27T00:00:00"}
