{"id":"https://openalex.org/W2188691787","doi":null,"title":"Vent Right and Then? Mechanical Ventilation, Dehumidification and Energy Use in Humid Climates","display_name":"Vent Right and Then? Mechanical Ventilation, Dehumidification and Energy Use in Humid Climates","publication_year":2014,"publication_date":"2014-01-01","ids":{"openalex":"https://openalex.org/W2188691787","mag":"2188691787"},"language":"en","primary_location":{"id":"mag:2188691787","doi":null,"is_oa":false,"landing_page_url":"http://fsec.ucf.edu/en/publications/pdf/FSEC-PF-460-14.pdf","pdf_url":null,"source":null,"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":null},"volume":null,"type":"article","is_traditional":true,"indexed_in":[],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5112509617","display_name":"Philip W. Fairey","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Philip Fairey","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"middle","author":{"id":"https://openalex.org/A5010010977","display_name":"Danny Parker","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Danny Parker","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"middle","author":{"id":"https://openalex.org/A5111508390","display_name":"Robin Vieira","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Robin Vieira","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"last","author":{"id":"https://openalex.org/A5085621044","display_name":"ERIC C. MARTIN","orcid":"https://orcid.org/0000-0002-7171-548X","observed_orcids":["https://orcid.org/0000-0002-7171-548X"]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"\u00c9ric Martin","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]}],"institutions":[],"countries_distinct_count":0,"institutions_distinct_count":0,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":{"value":0.0,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":null,"last_page":null},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10121","display_name":"Building Energy and Comfort Optimization","score":0.9369999766349792,"subfield":{"id":"https://openalex.org/subfields/2215","display_name":"Building and Construction"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10121","display_name":"Building Energy and Comfort Optimization","score":0.9369999766349792,"subfield":{"id":"https://openalex.org/subfields/2215","display_name":"Building and Construction"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11002","display_name":"Indoor Air Quality and Microbial Exposure","score":0.026000000536441803,"subfield":{"id":"https://openalex.org/subfields/2307","display_name":"Health, Toxicology and Mutagenesis"},"field":{"id":"https://openalex.org/fields/23","display_name":"Environmental Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T13263","display_name":"Building energy efficiency and sustainability","score":0.017899999395012856,"subfield":{"id":"https://openalex.org/subfields/2215","display_name":"Building and Construction"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/mechanical-ventilation","display_name":"mechanical ventilation","score":0.9639999866485596},{"id":"https://openalex.org/keywords/dehumidification","display_name":"dehumidification","score":0.8539999723434448},{"id":"https://openalex.org/keywords/humid-climate","display_name":"humid climate","score":0.8450000286102295},{"id":"https://openalex.org/keywords/indoor-relative-humidity","display_name":"indoor relative humidity","score":0.9629999995231628},{"id":"https://openalex.org/keywords/air-infiltration-rate","display_name":"air infiltration rate","score":0.5989999771118164},{"id":"https://openalex.org/keywords/air-sealing","display_name":"air sealing","score":0.5230000019073486},{"id":"https://openalex.org/keywords/cooling-energy-consumption","display_name":"cooling energy consumption","score":0.6510000228881836},{"id":"https://openalex.org/keywords/moisture-removal","display_name":"moisture removal","score":0.652999997138977}],"concepts":[{"id":"https://openalex.org/C206145494","wikidata":"https://www.wikidata.org/wiki/Q4654236","display_name":"ASHRAE 90.1","level":2,"score":0.8127361536026001},{"id":"https://openalex.org/C39432304","wikidata":"https://www.wikidata.org/wiki/Q188847","display_name":"Environmental science","level":0,"score":0.6764500141143799},{"id":"https://openalex.org/C200457457","wikidata":"https://www.wikidata.org/wiki/Q584049","display_name":"Ventilation (architecture)","level":2,"score":0.6699469089508057},{"id":"https://openalex.org/C2777080012","wikidata":"https://www.wikidata.org/wiki/Q3766250","display_name":"Mechanical ventilation","level":2,"score":0.5822676420211792},{"id":"https://openalex.org/C2779343474","wikidata":"https://www.wikidata.org/wiki/Q3109175","display_name":"Context (archaeology)","level":2,"score":0.5493306517601013},{"id":"https://openalex.org/C158960510","wikidata":"https://www.wikidata.org/wiki/Q180600","display_name":"Relative humidity","level":2,"score":0.5036429762840271},{"id":"https://openalex.org/C103742991","wikidata":"https://www.wikidata.org/wiki/Q173725","display_name":"Air conditioning","level":2,"score":0.43456488847732544},{"id":"https://openalex.org/C151420433","wikidata":"https://www.wikidata.org/wiki/Q180600","display_name":"Humidity","level":2,"score":0.42408937215805054},{"id":"https://openalex.org/C17005505","wikidata":"https://www.wikidata.org/wiki/Q11164636","display_name":"Energy recovery ventilation","level":4,"score":0.42203840613365173},{"id":"https://openalex.org/C176864760","wikidata":"https://www.wikidata.org/wiki/Q217651","display_name":"Moisture","level":2,"score":0.4101569652557373},{"id":"https://openalex.org/C153294291","wikidata":"https://www.wikidata.org/wiki/Q25261","display_name":"Meteorology","level":1,"score":0.3266105055809021},{"id":"https://openalex.org/C122346748","wikidata":"https://www.wikidata.org/wiki/Q1798773","display_name":"HVAC","level":3,"score":0.2794577181339264},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.22609904408454895},{"id":"https://openalex.org/C127313418","wikidata":"https://www.wikidata.org/wiki/Q1069","display_name":"Geology","level":0,"score":0.11142879724502563},{"id":"https://openalex.org/C205649164","wikidata":"https://www.wikidata.org/wiki/Q1071","display_name":"Geography","level":0,"score":0.10186043381690979},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.08650481700897217},{"id":"https://openalex.org/C151730666","wikidata":"https://www.wikidata.org/wiki/Q7205","display_name":"Paleontology","level":1,"score":0.0},{"id":"https://openalex.org/C118552586","wikidata":"https://www.wikidata.org/wiki/Q7867","display_name":"Psychiatry","level":1,"score":0.0},{"id":"https://openalex.org/C15744967","wikidata":"https://www.wikidata.org/wiki/Q9418","display_name":"Psychology","level":0,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"mag:2188691787","doi":null,"is_oa":false,"landing_page_url":"http://fsec.ucf.edu/en/publications/pdf/FSEC-PF-460-14.pdf","pdf_url":null,"source":null,"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":null}],"best_oa_location":null,"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/13","display_name":"Climate action","score":0.75}],"study_designs":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":6,"referenced_works":["https://openalex.org/W2182935677","https://openalex.org/W2184421385","https://openalex.org/W2283273815","https://openalex.org/W2336675327","https://openalex.org/W3195101188","https://openalex.org/W3200283427"],"related_works":["https://openalex.org/W2147430670","https://openalex.org/W7030079473","https://openalex.org/W3210119493","https://openalex.org/W7002018062","https://openalex.org/W2273883221","https://openalex.org/W2274506492","https://openalex.org/W7046040201","https://openalex.org/W2089331435","https://openalex.org/W4255239647","https://openalex.org/W2588978817"],"abstract_inverted_index":{"The":[0],"desirability":[1],"of":[2,24,35,63,97,131],"mechanical":[3,56,69,82,94,124],"ventilation":[4,45,70,83,96,125,220],"in":[5,17,103,126,165,192],"homes":[6,28,67,75,185,204],"and":[7,49,52,54,71,77,81,180,187,224],"acceptable":[8],"infiltration":[9],"rates":[10],"are":[11,41],"sometimes":[12],"contentious":[13],"topics":[14],"\u2013":[15],"particularly":[16],"humid":[18,129],"climates.":[19],"We":[20,58],"present":[21,60],"preliminary":[22],"results":[23,62,91,164],"two":[25],"monitored":[26],"lab":[27],"constructed":[29],"to":[30,84,144,157,171],"represent":[31],"the":[32,44,98,118,127,159],"thermal":[33],"characteristics":[34],"typical":[36,72,172],"existing":[37,74],"Florida":[38],"homes.":[39],"They":[40],"configured":[42],"for":[43,210],"study":[46],"with":[47,53,68,76,105,117,223],"tight":[48,99,160,184],"leaky":[50,119,203],"envelopes":[51],"without":[55,78,123,225],"ventilation.":[57],"also":[59,153,208],"simulation":[61],"high":[64],"performance":[65],"new":[66,183],"older":[73],"air":[79,147],"tightening":[80],"provide":[85],"added":[86],"context.":[87],"Lab":[88],"home":[89,100,120,161],"test":[90],"indicate":[92,154],"that":[93,155],"supply":[95],"(2":[101],"ach50)":[102,122,189,206],"accordance":[104],"ASHRAE":[106],"62.2-3013":[107],"increased":[108,139,146],"average":[109],"indoor":[110,167],"relative":[111,168],"humidity":[112,169],"by":[113,140],"2.2%":[114],"as":[115],"compared":[116],"(8":[121],"hot,":[128],"climate":[130,200],"central":[132],"Florida.":[133],"However,":[134],"cooling":[135],"energy":[136],"use":[137],"was":[138,216],"about":[141],"27%":[142],"due":[143,170],"substantially":[145],"conditioner":[148],"moisture":[149,174],"removal":[150],"(>63%).":[151],"Results":[152],"failure":[156],"ventilate":[158],"during":[162],"winter":[163],"excessive":[166],"internal":[173],"gains.":[175],"To":[176],"explore":[177],"other":[178],"conditions":[179],"climates,":[181],"highly-efficient":[182],"(1.5":[186],"3":[188],"were":[190,207],"simulated":[191,209],"twelve":[193],"TMY3":[194],"weather":[195],"files":[196],"representing":[197],"five":[198],"U.S.":[199],"zones.":[201],"Existing":[202],"(11":[205],"one":[211],"TMY":[212],"city.":[213],"Parametric":[214],"analysis":[215],"accomplished":[217],"using":[218],"different":[219],"system":[221],"types":[222],"dehumidification.":[226],"Background":[227]},"counts_by_year":[],"updated_date":"2026-09-22T06:50:58.402377","created_date":"2016-06-24T00:00:00"}
