{"id":"https://openalex.org/W2188504221","doi":null,"title":"PLC BASED PID IMPLEMENTATION IN PROCESS CONTROL OF TEMPERATURE FLOW AND LEVEL","display_name":"PLC BASED PID IMPLEMENTATION IN PROCESS CONTROL OF TEMPERATURE FLOW AND LEVEL","alternate_titles":[],"publication_year":2015,"publication_date":"2015-01-01","ids":{"openalex":"https://openalex.org/W2188504221","mag":"2188504221"},"language":"en","primary_location":{"id":"mag:2188504221","doi":null,"is_oa":false,"landing_page_url":"http://www.iaeme.com/MasterAdmin/UploadFolder/PLC%20BASED%20PID%20IMPLEMENTATION%20IN%20PROCESS%20CONTROL%20OF%20TEMPERATURE%20FLOW%20AND%20LEVEL/PLC%20BASED%20PID%20IMPLEMENTATION%20IN%20PROCESS%20CONTROL%20OF%20TEMPERATURE%20FLOW%20AND%20LEVEL.pdf","pdf_url":null,"source":null,"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":null},"parent_works":[],"lineage":["https://openalex.org/W2188504221"],"child_works_count":0,"type":"article","is_traditional":true,"indexed_in":[],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5080461174","display_name":"Ramavatar Singh Rathore","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Ramavatar Singh Rathore","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"middle","author":{"id":null,"display_name":"Anil Kumar Sharma","orcid":"https://orcid.org/0000-0001-9809-4700","observed_orcids":["https://orcid.org/0000-0001-9809-4700"]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Anil Kumar Sharma","raw_affiliation_strings":[],"raw_orcid":"https://orcid.org/0000-0001-9809-4700","affiliations":[]},{"author_position":"last","author":{"id":"https://openalex.org/A5081891046","display_name":"Hirendra Kr","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Hirendra Kr","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]}],"institutions":[],"countries_distinct_count":0,"institutions_distinct_count":0,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.9956,"has_fulltext":false,"cited_by_count":13,"citation_normalized_percentile":{"value":0.7691974,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":86,"max":96},"biblio":{"volume":null,"issue":null,"first_page":null,"last_page":null},"is_retracted":false,"is_pulled":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T13344","display_name":"Industrial Automation and Control Systems","score":0.9932000041007996,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T13344","display_name":"Industrial Automation and Control Systems","score":0.9932000041007996,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11081","display_name":"Advanced Control Systems Design","score":0.005100000184029341,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T14225","display_name":"Advanced Sensor and Control Systems","score":0.00039999998989515007,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/pid-control","display_name":"PID control","score":0.7900000214576721},{"id":"https://openalex.org/keywords/programmable-logic-controller","display_name":"programmable logic controller","score":0.9919999837875366},{"id":"https://openalex.org/keywords/temperature-control","display_name":"temperature control","score":0.9580000042915344},{"id":"https://openalex.org/keywords/flow-control","display_name":"flow control","score":0.9789999723434448},{"id":"https://openalex.org/keywords/level-control","display_name":"level control","score":0.9800000190734863},{"id":"https://openalex.org/keywords/ladder-logic-programming","display_name":"ladder diagram programming","score":0.6230000257492065},{"id":"https://openalex.org/keywords/codesys","display_name":"CODESYS","score":0.5370000004768372},{"id":"https://openalex.org/keywords/cascade-control","display_name":"cascade control","score":0.7870000004768372},{"id":"https://openalex.org/keywords/ratio-control","display_name":"ratio control","score":0.8960000276565552},{"id":"https://openalex.org/keywords/feedback-control","display_name":"feedback control","score":0.9319999814033508},{"id":"https://openalex.org/keywords/flow-sensors","display_name":"flow sensors","score":0.7310000061988831},{"id":"https://openalex.org/keywords/level-sensors","display_name":"level sensors","score":0.7599999904632568},{"id":"https://openalex.org/keywords/industrial-process-control","display_name":"industrial process control","score":0.6650000214576721}],"concepts":[{"id":"https://openalex.org/C47116090","wikidata":"https://www.wikidata.org/wiki/Q716829","display_name":"PID controller","level":3,"score":0.8711060881614685},{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.6700518727302551},{"id":"https://openalex.org/C536315585","wikidata":"https://www.wikidata.org/wiki/Q7698332","display_name":"Temperature control","level":2,"score":0.6386233568191528},{"id":"https://openalex.org/C203479927","wikidata":"https://www.wikidata.org/wiki/Q5165939","display_name":"Controller (irrigation)","level":2,"score":0.6038075089454651},{"id":"https://openalex.org/C173018170","wikidata":"https://www.wikidata.org/wiki/Q165678","display_name":"Microcontroller","level":2,"score":0.5801887512207031},{"id":"https://openalex.org/C37374048","wikidata":"https://www.wikidata.org/wiki/Q188674","display_name":"Programmable logic controller","level":2,"score":0.5682567358016968},{"id":"https://openalex.org/C98045186","wikidata":"https://www.wikidata.org/wiki/Q205663","display_name":"Process (computing)","level":2,"score":0.499981164932251},{"id":"https://openalex.org/C133731056","wikidata":"https://www.wikidata.org/wiki/Q4917288","display_name":"Control engineering","level":1,"score":0.47942155599594116},{"id":"https://openalex.org/C17500928","wikidata":"https://www.wikidata.org/wiki/Q959968","display_name":"Control system","level":2,"score":0.475408136844635},{"id":"https://openalex.org/C155386361","wikidata":"https://www.wikidata.org/wiki/Q1649571","display_name":"Process control","level":3,"score":0.4715965688228607},{"id":"https://openalex.org/C34146451","wikidata":"https://www.wikidata.org/wiki/Q5048094","display_name":"Cascade","level":2,"score":0.4410169720649719},{"id":"https://openalex.org/C81988521","wikidata":"https://www.wikidata.org/wiki/Q676838","display_name":"Control unit","level":2,"score":0.4211432933807373},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.3654463291168213},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.34317493438720703},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.24706357717514038},{"id":"https://openalex.org/C9390403","wikidata":"https://www.wikidata.org/wiki/Q3966","display_name":"Computer hardware","level":1,"score":0.10920971632003784},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.08053198456764221},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.0},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.0},{"id":"https://openalex.org/C42360764","wikidata":"https://www.wikidata.org/wiki/Q83588","display_name":"Chemical engineering","level":1,"score":0.0},{"id":"https://openalex.org/C6557445","wikidata":"https://www.wikidata.org/wiki/Q173113","display_name":"Agronomy","level":1,"score":0.0},{"id":"https://openalex.org/C86803240","wikidata":"https://www.wikidata.org/wiki/Q420","display_name":"Biology","level":0,"score":0.0}],"mesh":[],"locations_count":2,"locations":[{"id":"mag:2188504221","doi":null,"is_oa":false,"landing_page_url":"http://www.iaeme.com/MasterAdmin/UploadFolder/PLC%20BASED%20PID%20IMPLEMENTATION%20IN%20PROCESS%20CONTROL%20OF%20TEMPERATURE%20FLOW%20AND%20LEVEL/PLC%20BASED%20PID%20IMPLEMENTATION%20IN%20PROCESS%20CONTROL%20OF%20TEMPERATURE%20FLOW%20AND%20LEVEL.pdf","pdf_url":null,"source":null,"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":null},{"id":"pmh:oai:CiteSeerX.psu:10.1.1.695.4120","doi":null,"is_oa":false,"landing_page_url":"http://citeseerx.ist.psu.edu/viewdoc/summary?doi=10.1.1.695.4120","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"http://www.iaeme.com/MasterAdmin/UploadFolder/PLC+BASED+PID+IMPLEMENTATION+IN+PROCESS+CONTROL+OF+TEMPERATURE+FLOW+AND+LEVEL/PLC+BASED+PID+IMPLEMENTATION+IN+PROCESS+CONTROL+OF+TEMPERATURE+FLOW+AND+LEVEL.pdf","raw_type":"text"}],"best_oa_location":null,"sustainable_development_goals":[],"study_designs":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":20,"referenced_works":["https://openalex.org/W1598310993","https://openalex.org/W1908778769","https://openalex.org/W1969123050","https://openalex.org/W2009129255","https://openalex.org/W2021692831","https://openalex.org/W2023678973","https://openalex.org/W2050910562","https://openalex.org/W2054744791","https://openalex.org/W2105180218","https://openalex.org/W2117353021","https://openalex.org/W2120341780","https://openalex.org/W2146389119","https://openalex.org/W2167020817","https://openalex.org/W2183383576","https://openalex.org/W2187784317","https://openalex.org/W2321990534","https://openalex.org/W2535576260","https://openalex.org/W2543284068","https://openalex.org/W2548105809","https://openalex.org/W2741291035"],"related_works":["https://openalex.org/W2350586220","https://openalex.org/W2362993377","https://openalex.org/W2022817325","https://openalex.org/W2167020817","https://openalex.org/W150514662","https://openalex.org/W2376928977","https://openalex.org/W3027280649","https://openalex.org/W2021921686","https://openalex.org/W2313376602","https://openalex.org/W2350224724"],"abstract_inverted_index":{"In":[0,86,104,193],"the":[1,5,18,29,45,66,81,84,89,107,136,168,175,181,188,191,211],"present":[2],"Industrial":[3],"scenario":[4],"Temperature,":[6],"Flow,":[7],"Level,":[8],"Pressure":[9],"and":[10,129,151,162,203],"density":[11],"of":[12,28,47,83,109,165],"a":[13,71,75,141],"process":[14,214],"is":[15,23,36,50,91,112,140,172,185],"controlled":[16],"using":[17,40,115,190],"Proportional-Integral-Derivative":[19],"(PID)":[20],"controller":[21,54,60,111],"which":[22],"based":[24,92],"on":[25,93],"microcontroller.":[26],"Out":[27],"above":[30,212],"mentioned":[31,213],"variables":[32],"controlling,":[33,200],"Temperature":[34],"control":[35,42,65,138],"very":[37],"difficult":[38],"by":[39,114,174,187],"ordinary":[41],"techniques;":[43],"hence":[44],"motive":[46],"our":[48],"research":[49],"to":[51,64,68,74,198],"implement":[52],"PID":[53,110],"design":[55],"along":[56,99],"with":[57,100,179],"programmable":[58],"logic":[59],"(PLC)":[61],"in":[62,118,177,196],"order":[63],"time":[67],"heat":[69],"up":[70],"particular":[72],"solution":[73],"desired":[76,173],"temperature":[77,126,137],"efficiently":[78],"without":[79],"sacrificing":[80],"stability":[82],"system.":[85],"this":[87,105,194],"work":[88,106,195],"controlling":[90,108,210],"PLC":[94,119,199],"MISTUBISHI":[95],"NEXGENIE":[96],"1000":[97],"NG14RL":[98],"some":[101],"Analog":[102],"cards.":[103],"performed":[113],"ladder":[116],"diagram":[117],"software":[120],"Codesys":[121],"ENE":[122],"server":[123],"V2.3.":[124],"The":[125],"control,":[127],"flow":[128,160],"level":[130,163,171],"unit":[131,139,144,154],"NE40UX":[132],"are":[133,206],"used":[134,208],"where":[135],"special":[142,152],"I/O":[143,153],"that":[145,155,180],"receives":[146,156],"inputs":[147,157],"directly":[148,158],"from":[149,159],"RTDs":[150],"sensors":[161],"sensor":[164],"plant.":[166],"Whatever":[167],"temperature,":[169],"flow,":[170],"user":[176,189],"accordance":[178],"set":[182,186],"point":[183],"(SP)":[184],"PC.":[192],"addition":[197],"Cascade,":[201],"Ratio":[202],"Feedback":[204],"loops":[205],"also":[207],"for":[209]},"cited_by_api_url":"https://api.openalex.org/works?filter=cites:W2188504221","counts_by_year":[{"year":2026,"cited_by_count":1},{"year":2024,"cited_by_count":1},{"year":2022,"cited_by_count":1},{"year":2021,"cited_by_count":1},{"year":2020,"cited_by_count":2},{"year":2019,"cited_by_count":2},{"year":2018,"cited_by_count":3},{"year":2017,"cited_by_count":1},{"year":2015,"cited_by_count":1}],"updated_date":"2026-11-16T12:05:36.265796","created_date":"2016-06-24T00:00:00"}