{"id":"https://openalex.org/W2187779445","doi":null,"title":"Identification of the electric chiller model for the energyplus program using monitored data in an existing cooling plant","display_name":"Identification of the electric chiller model for the energyplus program using monitored data in an existing cooling plant","publication_year":2011,"publication_date":"2011-01-01","ids":{"openalex":"https://openalex.org/W2187779445","mag":"2187779445"},"language":"en","primary_location":{"id":"pmh:oai:espace2.etsmtl.ca:21067","doi":null,"is_oa":false,"landing_page_url":"https://espace2.etsmtl.ca/id/eprint/21067/","pdf_url":null,"source":{"id":"https://openalex.org/S4306402392","display_name":"Espace \u00c9TS (ETS)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I9736820","host_organization_name":"\u00c9cole de Technologie Sup\u00e9rieure","host_organization_lineage":["https://openalex.org/I9736820"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"acceptedVersion","is_accepted":true,"is_published":false,"raw_source_name":"","raw_type":"Compte rendu de conf\u00e9rence"},"volume":null,"type":"conference-paper","is_traditional":true,"indexed_in":[],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5041700976","display_name":"Danielle Monfet","orcid":"https://orcid.org/0000-0003-4122-0483","observed_orcids":["https://orcid.org/0000-0003-4122-0483"]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Danielle Monfet","raw_affiliation_strings":[],"raw_orcid":"https://orcid.org/0000-0003-4122-0483","affiliations":[]},{"author_position":"last","author":{"id":"https://openalex.org/A5086231003","display_name":"Radu Zmeureanu","orcid":"https://orcid.org/0000-0003-0469-9499","observed_orcids":["https://orcid.org/0000-0003-0469-9499"]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Radu Zmeureanu","raw_affiliation_strings":[],"raw_orcid":"https://orcid.org/0000-0003-0469-9499","affiliations":[]}],"institutions":[],"countries_distinct_count":0,"institutions_distinct_count":0,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":1.0827,"has_fulltext":false,"cited_by_count":11,"citation_normalized_percentile":{"value":0.80009266,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":88,"max":96},"biblio":{"volume":null,"issue":null,"first_page":null,"last_page":null},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10121","display_name":"Building Energy and Comfort Optimization","score":0.9965999722480774,"subfield":{"id":"https://openalex.org/subfields/2215","display_name":"Building and Construction"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10121","display_name":"Building Energy and Comfort Optimization","score":0.9965999722480774,"subfield":{"id":"https://openalex.org/subfields/2215","display_name":"Building and Construction"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11529","display_name":"Refrigeration and Air Conditioning Technologies","score":0.002300000051036477,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11185","display_name":"Integrated Energy Systems Optimization","score":9.999999747378752e-05,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/chiller-modeling","display_name":"chiller modeling","score":0.8159999847412109},{"id":"https://openalex.org/keywords/energyplus","display_name":"EnergyPlus","score":0.7739999890327454},{"id":"https://openalex.org/keywords/model-parameter-identification","display_name":"model parameter identification","score":0.6269999742507935},{"id":"https://openalex.org/keywords/cooling-plant","display_name":"cooling plant","score":0.8539999723434448},{"id":"https://openalex.org/keywords/hvac-system-simulation","display_name":"HVAC system simulation","score":0.39899998903274536},{"id":"https://openalex.org/keywords/data-driven-modeling","display_name":"data-driven modeling","score":0.3319999873638153}],"concepts":[{"id":"https://openalex.org/C4638862","wikidata":"https://www.wikidata.org/wiki/Q1501558","display_name":"Chiller","level":2,"score":0.8710273504257202},{"id":"https://openalex.org/C24463637","wikidata":"https://www.wikidata.org/wiki/Q5099037","display_name":"Chiller boiler system","level":5,"score":0.5325286388397217},{"id":"https://openalex.org/C139945424","wikidata":"https://www.wikidata.org/wiki/Q1940696","display_name":"Mean squared error","level":2,"score":0.5269955992698669},{"id":"https://openalex.org/C40293303","wikidata":"https://www.wikidata.org/wiki/Q27137","display_name":"Electric power","level":3,"score":0.5112936496734619},{"id":"https://openalex.org/C39432304","wikidata":"https://www.wikidata.org/wiki/Q188847","display_name":"Environmental science","level":0,"score":0.4858970046043396},{"id":"https://openalex.org/C182254935","wikidata":"https://www.wikidata.org/wiki/Q1722733","display_name":"Water chiller","level":4,"score":0.4533786177635193},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.39981991052627563},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.3872937858104706},{"id":"https://openalex.org/C105795698","wikidata":"https://www.wikidata.org/wiki/Q12483","display_name":"Statistics","level":1,"score":0.36925044655799866},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.25192779302597046},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.08168351650238037},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C131097465","wikidata":"https://www.wikidata.org/wiki/Q178898","display_name":"Gas compressor","level":2,"score":0.0},{"id":"https://openalex.org/C97355855","wikidata":"https://www.wikidata.org/wiki/Q11473","display_name":"Thermodynamics","level":1,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C199499590","wikidata":"https://www.wikidata.org/wiki/Q266790","display_name":"Refrigerant","level":3,"score":0.0}],"mesh":[],"locations_count":2,"locations":[{"id":"pmh:oai:espace2.etsmtl.ca:21067","doi":null,"is_oa":false,"landing_page_url":"https://espace2.etsmtl.ca/id/eprint/21067/","pdf_url":null,"source":{"id":"https://openalex.org/S4306402392","display_name":"Espace \u00c9TS (ETS)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I9736820","host_organization_name":"\u00c9cole de Technologie Sup\u00e9rieure","host_organization_lineage":["https://openalex.org/I9736820"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"acceptedVersion","is_accepted":true,"is_published":false,"raw_source_name":"","raw_type":"Compte rendu de conf\u00e9rence"},{"id":"mag:2187779445","doi":null,"is_oa":false,"landing_page_url":"https://www.researchgate.net/profile/R_Zmeureanu/publication/263280147_IDENTIFICATION_OF_THE_ELECTRIC_CHILLER_MODEL_FOR_THE_ENERGYPLUS_PROGRAM_USING_MONITORED_DATA_IN_AN_EXISTING_COOLING_PLANT/links/0c96053a77ac29ff14000000.pdf","pdf_url":null,"source":null,"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":null}],"best_oa_location":null,"sustainable_development_goals":[{"score":0.9090999960899353,"display_name":"Affordable and clean energy","id":"https://metadata.un.org/sdg/7"},{"score":0.685699999332428,"display_name":"Climate action","id":"https://metadata.un.org/sdg/13"}],"study_designs":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":4,"referenced_works":["https://openalex.org/W162693901","https://openalex.org/W1759799173","https://openalex.org/W2051326420","https://openalex.org/W2111909511"],"related_works":["https://openalex.org/W2057032101","https://openalex.org/W4400900168","https://openalex.org/W4412458917","https://openalex.org/W3168899032","https://openalex.org/W2932855283","https://openalex.org/W2018972999","https://openalex.org/W267178075","https://openalex.org/W3125880466","https://openalex.org/W7164925708","https://openalex.org/W2047995165"],"abstract_inverted_index":{"This":[0],"paper":[1],"proposes":[2],"an":[3,24],"approach":[4],"to":[5,30,63,72,103],"identify":[6,104],"the":[7,10,15,32,42,50,55,58,68,75,78,85,91,94,98,105,109,112,115],"coefficients":[8],"of":[9,39,47,57,67,111],"chiller":[11,44,96],"model":[12,106],"used":[13,29,102],"by":[14],"EnergyPlus":[16],"program.":[17],"Data":[18],"collected":[19,53],"every":[20],"15":[21],"minutes":[22],"from":[23],"existing":[25],"cooling":[26],"plant":[27],"are":[28,61,80],"evaluate":[31],"approach.":[33],"The":[34],"results":[35],"demonstrate":[36],"that":[37],"28-days":[38],"data":[40,48,100],"for":[41,49,84,90],"first":[43,92],"and":[45,82,93],"7-days":[46],"second":[51,95],"chiller,":[52],"at":[54],"beginning":[56],"summer":[59,76,113],"season,":[60,114],"sufficient":[62],"obtain":[64],"accurate":[65],"prediction":[66],"electric":[69,86],"power":[70,87],"input":[71],"chillers":[73],"over":[74,97],"season:":[77],"CV(RMSE)":[79,116],"3.7%":[81],"4.9%":[83],"input,":[88],"respectively,":[89],"training":[99],"set":[101],"coefficients.":[107],"For":[108],"remainder":[110],"is":[117],"below":[118],"7.6%.":[119]},"counts_by_year":[{"year":2024,"cited_by_count":1},{"year":2023,"cited_by_count":1},{"year":2021,"cited_by_count":2},{"year":2020,"cited_by_count":2},{"year":2019,"cited_by_count":2},{"year":2018,"cited_by_count":2},{"year":2013,"cited_by_count":1}],"updated_date":"2026-11-05T12:25:35.769452","created_date":"2016-06-24T00:00:00"}