{"id":"https://openalex.org/W2186970159","doi":null,"title":"Parametric Analysis of Surface Condenser for Thermal Power Plant","display_name":"Parametric Analysis of Surface Condenser for Thermal Power Plant","publication_year":2013,"publication_date":"2013-01-01","ids":{"openalex":"https://openalex.org/W2186970159","mag":"2186970159"},"language":"en","primary_location":{"id":"mag:2186970159","doi":null,"is_oa":false,"landing_page_url":"http://inpressco.com/wp-content/uploads/2013/12/Paper8155-159.pdf","pdf_url":null,"source":null,"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":null},"volume":null,"type":"article","indexed_in":[],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5024131919","display_name":"Vikram Haldkar","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Vikram Haldkar","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"last","author":{"id":"https://openalex.org/A5043447365","display_name":"Abhay Sharma","orcid":"https://orcid.org/0000-0003-4417-7871","observed_orcids":["https://orcid.org/0000-0003-4417-7871"]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Abhay Kumar Sharma","raw_affiliation_strings":[],"raw_orcid":"https://orcid.org/0000-0003-4417-7871","affiliations":[]}],"institutions":[],"countries_distinct_count":0,"institutions_distinct_count":0,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.7999,"has_fulltext":false,"cited_by_count":8,"citation_normalized_percentile":{"value":0.77521169,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":88,"max":97},"biblio":{"volume":null,"issue":null,"first_page":null,"last_page":null},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T13856","display_name":"Advanced Power Generation Technologies","score":0.9053000211715698,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T13856","display_name":"Advanced Power Generation Technologies","score":0.9053000211715698,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10568","display_name":"Thermodynamic and Exergetic Analyses of Power and Cooling Systems","score":0.07580000162124634,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10998","display_name":"Heat Transfer and Optimization","score":0.010700000450015068,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/surface-condensers","display_name":"surface condensers","score":0.9869999885559082},{"id":"https://openalex.org/keywords/thermal-power-plants","display_name":"thermal power plants","score":0.9559999704360962},{"id":"https://openalex.org/keywords/parametric-study","display_name":"parametric study","score":0.7319999933242798},{"id":"https://openalex.org/keywords/heat-rate","display_name":"heat rate","score":0.7910000085830688},{"id":"https://openalex.org/keywords/power-output","display_name":"output power","score":0.9430000185966492},{"id":"https://openalex.org/keywords/condenser-pressure","display_name":"condenser pressure","score":0.8500000238418579},{"id":"https://openalex.org/keywords/temperature-difference","display_name":"temperature difference","score":0.9309999942779541},{"id":"https://openalex.org/keywords/condenser-efficiency","display_name":"condenser efficiency","score":0.8009999990463257},{"id":"https://openalex.org/keywords/operating-conditions","display_name":"operating conditions","score":0.5609999895095825}],"concepts":[{"id":"https://openalex.org/C2780934509","wikidata":"https://www.wikidata.org/wiki/Q571589","display_name":"Condenser (optics)","level":3,"score":0.841719388961792},{"id":"https://openalex.org/C2039551","wikidata":"https://www.wikidata.org/wiki/Q200297","display_name":"Thermal power station","level":2,"score":0.6518343687057495},{"id":"https://openalex.org/C4311470","wikidata":"https://www.wikidata.org/wiki/Q159719","display_name":"Power station","level":2,"score":0.6185518503189087},{"id":"https://openalex.org/C73673526","wikidata":"https://www.wikidata.org/wiki/Q1158818","display_name":"Steam-electric power station","level":4,"score":0.5581009984016418},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.5426322817802429},{"id":"https://openalex.org/C135824740","wikidata":"https://www.wikidata.org/wiki/Q15273089","display_name":"Surface condenser","level":4,"score":0.4843907952308655},{"id":"https://openalex.org/C194945478","wikidata":"https://www.wikidata.org/wiki/Q5693253","display_name":"Heat capacity rate","level":4,"score":0.4696064889431},{"id":"https://openalex.org/C39432304","wikidata":"https://www.wikidata.org/wiki/Q188847","display_name":"Environmental science","level":0,"score":0.4366476237773895},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.4340800940990448},{"id":"https://openalex.org/C172120300","wikidata":"https://www.wikidata.org/wiki/Q1134348","display_name":"Volumetric flow rate","level":2,"score":0.42717546224594116},{"id":"https://openalex.org/C116915560","wikidata":"https://www.wikidata.org/wiki/Q83504","display_name":"Nuclear engineering","level":1,"score":0.4259764552116394},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.3495301604270935},{"id":"https://openalex.org/C57879066","wikidata":"https://www.wikidata.org/wiki/Q41217","display_name":"Mechanics","level":1,"score":0.2689926028251648},{"id":"https://openalex.org/C14794904","wikidata":"https://www.wikidata.org/wiki/Q189859","display_name":"Steam turbine","level":2,"score":0.20722678303718567},{"id":"https://openalex.org/C97355855","wikidata":"https://www.wikidata.org/wiki/Q11473","display_name":"Thermodynamics","level":1,"score":0.1975034475326538},{"id":"https://openalex.org/C107706546","wikidata":"https://www.wikidata.org/wiki/Q189124","display_name":"Heat exchanger","level":2,"score":0.18283280730247498},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.17742371559143066},{"id":"https://openalex.org/C110910425","wikidata":"https://www.wikidata.org/wiki/Q900729","display_name":"Combined cycle","level":3,"score":0.15100222826004028},{"id":"https://openalex.org/C192811776","wikidata":"https://www.wikidata.org/wiki/Q2164304","display_name":"Superheated steam","level":3,"score":0.15054845809936523},{"id":"https://openalex.org/C48632124","wikidata":"https://www.wikidata.org/wiki/Q617088","display_name":"Heat spreader","level":3,"score":0.09402135014533997},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.07448747754096985},{"id":"https://openalex.org/C2778449969","wikidata":"https://www.wikidata.org/wiki/Q130760","display_name":"Turbine","level":2,"score":0.07411009073257446},{"id":"https://openalex.org/C120665830","wikidata":"https://www.wikidata.org/wiki/Q14620","display_name":"Optics","level":1,"score":0.0},{"id":"https://openalex.org/C2982854487","wikidata":"https://www.wikidata.org/wiki/Q9128","display_name":"Light source","level":2,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"mag:2186970159","doi":null,"is_oa":false,"landing_page_url":"http://inpressco.com/wp-content/uploads/2013/12/Paper8155-159.pdf","pdf_url":null,"source":null,"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":null}],"best_oa_location":null,"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/7","display_name":"Affordable and clean energy","score":0.878000020980835}],"study_designs":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":5,"referenced_works":["https://openalex.org/W2135952982","https://openalex.org/W2228713747","https://openalex.org/W2283775401","https://openalex.org/W2339376361","https://openalex.org/W2340008124"],"related_works":["https://openalex.org/W7097307868","https://openalex.org/W2932316575","https://openalex.org/W7096758927","https://openalex.org/W7130715247","https://openalex.org/W2950461707","https://openalex.org/W2608521390","https://openalex.org/W2769227367","https://openalex.org/W2283775401","https://openalex.org/W2340008124","https://openalex.org/W135351605"],"abstract_inverted_index":{"The":[0,9],"thermal":[1,10,67],"power":[2,11,46,62,68,76,86,100,148,171],"plants":[3,12,47],"are":[4,13,35,48,51,80,90,104],"used":[5],"to":[6,57,71],"generate":[7],"power.":[8],"designed":[14,40,75],"based":[15],"on":[16],"required":[17],"conditions":[18,34,108,145],"(like":[19],"a":[20,92],"good":[21],"quality":[22],"of":[23,28,53,66,94,109,114,124,132,167],"steam,":[24],"pressure":[25],"and":[26,63,77,101,127,150,170],"temperature":[27],"steam":[29],"etc.),":[30],"but":[31],"actually":[32],"inlet":[33],"not":[36],"as":[37],"per":[38],"the":[39,74,85,97,117,122,133,159,165,168],"conditions.":[41],"In":[42],"practical":[43],"situations,":[44],"when":[45],"installed":[49],"there":[50],"lots":[52],"constraints.":[54],"This":[55,155],"tends":[56],"reduce":[58],"or":[59,161],"increase":[60],"output":[61,149],"heat":[64,78,102,151],"rate":[65,79,103,113,152],"plants.":[69],"Due":[70],"these":[72],"conditions,":[73],"never":[81],"achieved.":[82],"Variations":[83],"in":[84],"outputs":[87],"from":[88],"plant":[89],"always":[91],"matter":[93],"disputes.":[95],"So":[96],"parameters":[98,162],"for":[99,106],"generated":[105],"different":[107],"condenser":[110,169],"pressure,":[111],"flow":[112],"water":[115],"through":[116],"condenser,":[118],"Temperature":[119],"difference.":[120],"On":[121],"basis":[123],"site":[125],"measurement":[126],"design":[128],"data":[129],"collection":[130],"performance":[131],"Condenser":[134],"unit":[135],"can":[136],"be":[137],"evaluated.":[138],"These":[139],"evaluations":[140],"indicate":[141],"that":[142],"if":[143],"operating":[144],"vary,":[146],"then":[147],"also":[153],"vary.":[154],"paper":[156],"deals":[157],"with":[158],"factors":[160],"which":[163],"reduced":[164],"efficiency":[166],"plant.":[172]},"counts_by_year":[{"year":2021,"cited_by_count":1},{"year":2018,"cited_by_count":1},{"year":2017,"cited_by_count":2},{"year":2015,"cited_by_count":1},{"year":2014,"cited_by_count":3}],"updated_date":"2025-11-06T04:12:42.849631","created_date":"2016-06-24T00:00:00"}
