{"id":"https://openalex.org/W2186902808","doi":null,"title":"EMBEDDED WEARABLE SYSTEM FOR HYDRATION MEASUREMENT","display_name":"EMBEDDED WEARABLE SYSTEM FOR HYDRATION MEASUREMENT","publication_year":2011,"publication_date":"2011-01-01","ids":{"openalex":"https://openalex.org/W2186902808","mag":"2186902808"},"language":"en","primary_location":{"id":"mag:2186902808","doi":null,"is_oa":false,"landing_page_url":"http://cibtech.org/J-ENGINEERING-TECHNOLOGY/PUBLICATIONS/2011/Vol%201%20No.%201/019-JET-KAMAT.pdf","pdf_url":null,"source":null,"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":null},"volume":null,"type":"article","is_traditional":true,"indexed_in":[],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5075674913","display_name":"Pooja A. Uchagaonkar","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Pooja A. Uchagaonkar","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"middle","author":{"id":"https://openalex.org/A5001971706","display_name":"Shubham Shinde","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Shubham Shinde","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"last","author":{"id":"https://openalex.org/A5103547675","display_name":"Vishal V. Patil","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Vishal V. Patil","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]}],"institutions":[],"countries_distinct_count":0,"institutions_distinct_count":0,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.1665,"has_fulltext":false,"cited_by_count":3,"citation_normalized_percentile":{"value":0.55700896,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":88,"max":93},"biblio":{"volume":null,"issue":null,"first_page":null,"last_page":null},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11196","display_name":"Non-Invasive Vital Sign Monitoring","score":0.5336999893188477,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11196","display_name":"Non-Invasive Vital Sign Monitoring","score":0.5336999893188477,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12279","display_name":"Body Composition Measurement Techniques","score":0.2093999981880188,"subfield":{"id":"https://openalex.org/subfields/2737","display_name":"Physiology (medical)"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},{"id":"https://openalex.org/T11932","display_name":"Wireless Body Area Networks","score":0.1054999977350235,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/hydration-monitoring","display_name":"hydration monitoring","score":0.9210000038146973},{"id":"https://openalex.org/keywords/dehydration","display_name":"dehydration","score":0.8379999995231628},{"id":"https://openalex.org/keywords/bioelectrical-impedance-analysis","display_name":"bioelectrical impedance analysis","score":0.9860000014305115},{"id":"https://openalex.org/keywords/wearable-medical-devices","display_name":"wearable medical devices","score":0.972000002861023},{"id":"https://openalex.org/keywords/continuous-physiological-monitoring","display_name":"continuous physiological monitoring","score":0.7639999985694885}],"concepts":[{"id":"https://openalex.org/C150594956","wikidata":"https://www.wikidata.org/wiki/Q1334829","display_name":"Wearable computer","level":2,"score":0.8150780200958252},{"id":"https://openalex.org/C90734943","wikidata":"https://www.wikidata.org/wiki/Q17008777","display_name":"Conceptualization","level":2,"score":0.583540141582489},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.5455120205879211},{"id":"https://openalex.org/C33872192","wikidata":"https://www.wikidata.org/wiki/Q864287","display_name":"Bioelectrical impedance analysis","level":3,"score":0.43342870473861694},{"id":"https://openalex.org/C54290928","wikidata":"https://www.wikidata.org/wiki/Q4845080","display_name":"Wearable technology","level":3,"score":0.4127143621444702},{"id":"https://openalex.org/C107457646","wikidata":"https://www.wikidata.org/wiki/Q207434","display_name":"Human\u2013computer interaction","level":1,"score":0.3907884359359741},{"id":"https://openalex.org/C112930515","wikidata":"https://www.wikidata.org/wiki/Q4389547","display_name":"Risk analysis (engineering)","level":1,"score":0.3237583339214325},{"id":"https://openalex.org/C71924100","wikidata":"https://www.wikidata.org/wiki/Q11190","display_name":"Medicine","level":0,"score":0.20617714524269104},{"id":"https://openalex.org/C149635348","wikidata":"https://www.wikidata.org/wiki/Q193040","display_name":"Embedded system","level":1,"score":0.19418078660964966},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.1339169144630432},{"id":"https://openalex.org/C142724271","wikidata":"https://www.wikidata.org/wiki/Q7208","display_name":"Pathology","level":1,"score":0.0},{"id":"https://openalex.org/C2780221984","wikidata":"https://www.wikidata.org/wiki/Q131191","display_name":"Body mass index","level":2,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"mag:2186902808","doi":null,"is_oa":false,"landing_page_url":"http://cibtech.org/J-ENGINEERING-TECHNOLOGY/PUBLICATIONS/2011/Vol%201%20No.%201/019-JET-KAMAT.pdf","pdf_url":null,"source":null,"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":null}],"best_oa_location":null,"sustainable_development_goals":[{"display_name":"Good health and well-being","score":0.504800021648407,"id":"https://metadata.un.org/sdg/3"}],"study_designs":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":10,"referenced_works":["https://openalex.org/W1984240987","https://openalex.org/W2012213266","https://openalex.org/W2016832091","https://openalex.org/W2047922146","https://openalex.org/W2099354209","https://openalex.org/W2101713668","https://openalex.org/W2115320557","https://openalex.org/W2126870209","https://openalex.org/W2165894511","https://openalex.org/W2418216367"],"related_works":["https://openalex.org/W4385293391","https://openalex.org/W3208064511","https://openalex.org/W4292865274","https://openalex.org/W2603315612","https://openalex.org/W2599329807","https://openalex.org/W4403276783","https://openalex.org/W4412399930","https://openalex.org/W7160266099","https://openalex.org/W6898721960","https://openalex.org/W4384703541"],"abstract_inverted_index":{"As":[0],"far":[1],"as":[2,98],"the":[3,10,15,74,83,91,95,117,134],"human":[4,63,84],"physiology":[5],"is":[6,9,33,47,140],"concerned,":[7],"water":[8,38],"most":[11],"vital":[12],"element":[13],"for":[14,78],"overall":[16],"well":[17,109],"being.":[18,64,85],"It":[19],"plays":[20],"crucial":[21],"role":[22],"in":[23,36,39,51,61,82,94,137],"all":[24],"bodily":[25],"processes":[26],"by":[27,111],"providing":[28],"a":[29,34,40,62],"universal":[30],"medium.":[31],"Dehydration":[32,54],"condition,":[35],"which":[37],"living":[41],"body":[42],"reduces":[43],"unusually,":[44],"and":[45,58,71,104,107,114],"it":[46],"likely":[48],"to":[49],"encounter":[50],"daily":[52],"life.":[53],"impairs":[55],"both":[56],"physical":[57],"mental":[59],"performance":[60],"The":[65],"present":[66],"paper":[67,139],"reports":[68],"conceptualization,":[69],"design":[70],"development":[72],"of":[73],"wearable":[75],"embedded":[76],"device":[77],"hydration":[79,131],"level":[80],"measurement":[81],"Wearable":[86],"Medical":[87],"Devices":[88],"(WMDs)":[89],"are":[90,129],"emerging":[92],"trends":[93],"biomedical":[96],"domain":[97],"they":[99],"offer":[100],"patient":[101],"management":[102],"system":[103],"ensures":[105],"heath":[106],"medical":[108,119],"being":[110],"continuous":[112],"monitoring":[113,132],"thus":[115],"makes":[116],"ubiquitous":[118],"treatment":[120],"possible":[121],"that":[122],"too":[123],"at":[124],"minimal":[125],"cost.":[126],"Though":[127],"there":[128],"several":[130],"techniques,":[133],"one":[135],"used":[136],"this":[138],"bioelectrical":[141],"Impedance":[142],"Analysis":[143],"(BIA).":[144]},"counts_by_year":[{"year":2023,"cited_by_count":1},{"year":2020,"cited_by_count":1},{"year":2014,"cited_by_count":1}],"updated_date":"2026-11-04T10:54:05.112534","created_date":"2016-06-24T00:00:00"}
