{"id":"https://openalex.org/W2186018345","doi":null,"title":"Can Conventional Cooling Equipment Meet Dehumidification Needs for Houses in Humid Climates","display_name":"Can Conventional Cooling Equipment Meet Dehumidification Needs for Houses in Humid Climates","publication_year":2008,"publication_date":"2008-01-01","ids":{"openalex":"https://openalex.org/W2186018345","mag":"2186018345"},"language":"en","primary_location":{"id":"mag:2186018345","doi":null,"is_oa":false,"landing_page_url":"https://aceee.org/files/proceedings/2008/data/papers/1_449.pdf","pdf_url":null,"source":null,"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":null},"volume":null,"type":"article","is_traditional":true,"indexed_in":[],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5015996001","display_name":"Don Shirey","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Don B. Shirey","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"last","author":{"id":"https://openalex.org/A5026046377","display_name":"C. T. Keith","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"C. T. Keith","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]}],"institutions":[],"countries_distinct_count":0,"institutions_distinct_count":0,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":1.2024,"has_fulltext":false,"cited_by_count":11,"citation_normalized_percentile":{"value":0.86857325,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":87,"max":96},"biblio":{"volume":null,"issue":null,"first_page":null,"last_page":null},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10121","display_name":"Building Energy and Comfort Optimization","score":0.9848999977111816,"subfield":{"id":"https://openalex.org/subfields/2215","display_name":"Building and Construction"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10121","display_name":"Building Energy and Comfort Optimization","score":0.9848999977111816,"subfield":{"id":"https://openalex.org/subfields/2215","display_name":"Building and Construction"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11529","display_name":"Refrigeration and Air Conditioning Technologies","score":0.007199999876320362,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11774","display_name":"Adsorption and Cooling Systems","score":0.004000000189989805,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/dehumidification","display_name":"dehumidification","score":0.8980000019073486},{"id":"https://openalex.org/keywords/humid-climate","display_name":"humid climate","score":0.8579999804496765},{"id":"https://openalex.org/keywords/indoor-humidity-control","display_name":"indoor humidity control","score":0.6079999804496765},{"id":"https://openalex.org/keywords/continuous-ventilation","display_name":"continuous ventilation","score":0.5870000123977661},{"id":"https://openalex.org/keywords/sensible-heat-ratio","display_name":"sensible heat ratio","score":0.8180000185966492},{"id":"https://openalex.org/keywords/overcooling","display_name":"overcooling","score":0.7129999995231628},{"id":"https://openalex.org/keywords/moisture-evaporation","display_name":"moisture evaporation","score":0.6809999942779541},{"id":"https://openalex.org/keywords/trnsys-simulation","display_name":"TRNSYS simulation","score":0.5830000042915344},{"id":"https://openalex.org/keywords/moisture-removal","display_name":"moisture removal","score":0.4169999957084656}],"concepts":[{"id":"https://openalex.org/C59242433","wikidata":"https://www.wikidata.org/wiki/Q1480581","display_name":"Sensible heat","level":2,"score":0.6843627095222473},{"id":"https://openalex.org/C39432304","wikidata":"https://www.wikidata.org/wiki/Q188847","display_name":"Environmental science","level":0,"score":0.6609598994255066},{"id":"https://openalex.org/C151420433","wikidata":"https://www.wikidata.org/wiki/Q180600","display_name":"Humidity","level":2,"score":0.5373033881187439},{"id":"https://openalex.org/C2778457487","wikidata":"https://www.wikidata.org/wiki/Q2384813","display_name":"TRNSYS","level":3,"score":0.5124569535255432},{"id":"https://openalex.org/C4638862","wikidata":"https://www.wikidata.org/wiki/Q1501558","display_name":"Chiller","level":2,"score":0.47039923071861267},{"id":"https://openalex.org/C164915370","wikidata":"https://www.wikidata.org/wiki/Q5167494","display_name":"Cooling capacity","level":2,"score":0.4687020480632782},{"id":"https://openalex.org/C79795727","wikidata":"https://www.wikidata.org/wiki/Q3068508","display_name":"Passive cooling","level":3,"score":0.4228290319442749},{"id":"https://openalex.org/C176864760","wikidata":"https://www.wikidata.org/wiki/Q217651","display_name":"Moisture","level":2,"score":0.41789355874061584},{"id":"https://openalex.org/C2781099182","wikidata":"https://www.wikidata.org/wiki/Q24963825","display_name":"Cooling load","level":3,"score":0.41540828347206116},{"id":"https://openalex.org/C153294291","wikidata":"https://www.wikidata.org/wiki/Q25261","display_name":"Meteorology","level":1,"score":0.372364342212677},{"id":"https://openalex.org/C21880701","wikidata":"https://www.wikidata.org/wiki/Q2144042","display_name":"Process engineering","level":1,"score":0.3203028440475464},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.3066951334476471},{"id":"https://openalex.org/C103742991","wikidata":"https://www.wikidata.org/wiki/Q173725","display_name":"Air conditioning","level":2,"score":0.23847419023513794},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.1974288821220398},{"id":"https://openalex.org/C204530211","wikidata":"https://www.wikidata.org/wiki/Q752823","display_name":"Thermal","level":2,"score":0.08395051956176758},{"id":"https://openalex.org/C97355855","wikidata":"https://www.wikidata.org/wiki/Q11473","display_name":"Thermodynamics","level":1,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"mag:2186018345","doi":null,"is_oa":false,"landing_page_url":"https://aceee.org/files/proceedings/2008/data/papers/1_449.pdf","pdf_url":null,"source":null,"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":null}],"best_oa_location":null,"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/13","display_name":"Climate action","score":0.5351999998092651}],"study_designs":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":3,"referenced_works":["https://openalex.org/W1545228857","https://openalex.org/W2273883221","https://openalex.org/W3200993333"],"related_works":["https://openalex.org/W7134488129","https://openalex.org/W2182108742","https://openalex.org/W6983767169","https://openalex.org/W2117378337","https://openalex.org/W7017215515","https://openalex.org/W4321177614","https://openalex.org/W241601475","https://openalex.org/W2790253721","https://openalex.org/W2588978817","https://openalex.org/W209662214"],"abstract_inverted_index":{"Traditionally,":[0],"conventional":[1,126],"cooling":[2,132,143,152,187,202],"systems":[3,153,194],"have":[4,23,29],"been":[5],"considered":[6],"adequate":[7],"for":[8,205],"meeting":[9],"dehumidification":[10,69,198],"loads":[11,26,188],"even":[12],"in":[13,139,210],"the":[14,122,171,180],"most":[15],"humid":[16],"climates.":[17],"However,":[18],"as":[19,128,130,157,159],"high-efficiency":[20],"home":[21],"designs":[22,59],"reduced":[24],"sensible":[25,142,147,186,201],"and":[27,45,78,90,108,111],"codes":[28],"begun":[30],"requiring":[31],"continuous":[32,61],"outdoor":[33],"ventilation":[34,62,109],"air,":[35],"high":[36,181],"indoor":[37,73],"humidity":[38,74,182],"conditions":[39,215],"are":[40,63,94,189],"becoming":[41],"more":[42,64,136],"prevalent":[43],"(Rudd":[44],"Henderson":[46],"2007).":[47,80],"This":[48],"paper":[49],"presents":[50],"detailed":[51,101],"simulation":[52,83,116,174],"results":[53,175],"that":[54,56,93,134,162,177],"confirm":[55],"highefficiency":[57],"envelope":[58],"with":[60,141,199],"likely":[65],"to":[66,70,96,120,212],"require":[67],"explicit":[68,197],"maintain":[71,213],"acceptable":[72],"levels":[75],"(Henderson,":[76],"Shirey":[77],"Raustad":[79],"The":[81,115,150,173],"TRNSYS-based":[82],"model":[84,117],"considers":[85],"several":[86],"aspects":[87],"of":[88,124,179,208],"building":[89],"equipment":[91],"performance":[92],"critical":[95],"quantifying":[97],"these":[98],"impacts,":[99,110],"including":[100],"coil":[102],"models,":[103],"off-cycle":[104],"moisture":[105,137],"evaporation,":[106],"infiltration":[107],"duct":[112],"air":[113,165],"leakage.":[114],"was":[118],"used":[119],"evaluate":[121],"efficacy":[123],"using":[125],"dehumidifiers":[127],"well":[129,158],"enhanced":[131,151],"technologies":[133],"provide":[135,196],"removal":[138],"conjunction":[140],"(i.e.,":[144],"a":[145],"lower":[146],"heat":[148],"ratio).":[149],"use":[154],"condenser":[155],"reheat":[156],"control":[160],"enhancements":[161],"reduce":[163],"supply":[164],"flow":[166],"rates":[167],"and/or":[168],"conditionally":[169],"overcool":[170],"space.":[172],"show":[176],"many":[178],"periods":[183],"occur":[184],"when":[185],"modest":[190],"or":[191,203],"non-existent.":[192],"Therefore,":[193],"must":[195],"little-to-no":[200],"allow":[204],"some":[206],"degree":[207],"overcooling":[209],"order":[211],"space":[214],"below":[216],"60%":[217],"RH.":[218]},"counts_by_year":[{"year":2023,"cited_by_count":1},{"year":2021,"cited_by_count":1},{"year":2020,"cited_by_count":1},{"year":2019,"cited_by_count":1},{"year":2018,"cited_by_count":2},{"year":2016,"cited_by_count":1},{"year":2014,"cited_by_count":2},{"year":2013,"cited_by_count":1}],"updated_date":"2026-11-04T10:54:05.112534","created_date":"2016-06-24T00:00:00"}