{"id":"https://openalex.org/W2184828827","doi":null,"title":"Back-EMF BasedDetection ofStator Winding Inter-turn Fault forPM Synchronous MotorDrives","display_name":"Back-EMF BasedDetection ofStator Winding Inter-turn Fault forPM Synchronous MotorDrives","alternate_titles":[],"publication_year":2007,"publication_date":"2007-01-01","ids":{"openalex":"https://openalex.org/W2184828827","mag":"2184828827"},"language":"en","primary_location":{"id":"mag:2184828827","doi":null,"is_oa":false,"landing_page_url":"https://ieeexplore.ieee.org/abstract/document/4544105","pdf_url":null,"source":null,"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":null},"parent_works":[],"lineage":["https://openalex.org/W2184828827"],"child_works_count":0,"type":"article","is_traditional":true,"indexed_in":[],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5016291572","display_name":"Thierry Boileau","orcid":"https://orcid.org/0000-0001-8766-1597","observed_orcids":["https://orcid.org/0000-0001-8766-1597"]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Thierry Boileau","raw_affiliation_strings":[],"raw_orcid":"https://orcid.org/0000-0001-8766-1597","affiliations":[]},{"author_position":"middle","author":{"id":"https://openalex.org/A5080591980","display_name":"Babak Nahid\u2010Mobarakeh","orcid":"https://orcid.org/0000-0003-3452-2731","observed_orcids":["https://orcid.org/0000-0003-3452-2731"]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Babak Nahid\u2013Mobarakeh","raw_affiliation_strings":[],"raw_orcid":"https://orcid.org/0000-0003-3452-2731","affiliations":[]},{"author_position":"last","author":{"id":"https://openalex.org/A5077777665","display_name":"Farid Meibody\u2010Tabar","orcid":"https://orcid.org/0000-0001-5242-9210","observed_orcids":["https://orcid.org/0000-0001-5242-9210"]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Farid Meibody\u2010Tabar","raw_affiliation_strings":[],"raw_orcid":"https://orcid.org/0000-0001-5242-9210","affiliations":[]}],"institutions":[],"countries_distinct_count":0,"institutions_distinct_count":0,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.4908,"has_fulltext":false,"cited_by_count":2,"citation_normalized_percentile":{"value":0.7226119,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":87,"max":93},"biblio":{"volume":null,"issue":null,"first_page":null,"last_page":null},"is_retracted":false,"is_pulled":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10220","display_name":"Machine Fault Diagnosis Techniques","score":0.7592999935150146,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10220","display_name":"Machine Fault Diagnosis Techniques","score":0.7592999935150146,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10278","display_name":"Electric Motor Design and Analysis","score":0.16990000009536743,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10504","display_name":"Sensorless Control of Electric Motors","score":0.045499999076128006,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/permanent-magnet-synchronous-motor","display_name":"permanent magnet synchronous motor","score":0.8230000138282776},{"id":"https://openalex.org/keywords/back-emf","display_name":"back electromotive force","score":0.878000020980835},{"id":"https://openalex.org/keywords/fault-detection","display_name":"fault detection","score":0.9399999976158142},{"id":"https://openalex.org/keywords/negative-sequence-impedance","display_name":"negative sequence impedance","score":0.5979999899864197},{"id":"https://openalex.org/keywords/second-harmonic","display_name":"second harmonic","score":0.6100000143051147},{"id":"https://openalex.org/keywords/motor-condition-monitoring","display_name":"motor condition monitoring","score":0.5479999780654907},{"id":"https://openalex.org/keywords/online-fault-diagnosis","display_name":"real-time fault diagnosis","score":0.6290000081062317}],"concepts":[{"id":"https://openalex.org/C85641259","wikidata":"https://www.wikidata.org/wiki/Q290042","display_name":"Turn (biochemistry)","level":2,"score":0.6856305003166199},{"id":"https://openalex.org/C175551986","wikidata":"https://www.wikidata.org/wiki/Q47089","display_name":"Fault (geology)","level":2,"score":0.6657376289367676},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.5156132578849792},{"id":"https://openalex.org/C152745839","wikidata":"https://www.wikidata.org/wiki/Q5438153","display_name":"Fault detection and isolation","level":3,"score":0.5118317008018494},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.4722190201282501},{"id":"https://openalex.org/C17829176","wikidata":"https://www.wikidata.org/wiki/Q179043","display_name":"Electrical impedance","level":2,"score":0.4261455237865448},{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.41100212931632996},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.2865108847618103},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.24022015929222107},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.1279037892818451},{"id":"https://openalex.org/C172707124","wikidata":"https://www.wikidata.org/wiki/Q423488","display_name":"Actuator","level":2,"score":0.10895019769668579},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.10619780421257019},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.06610897183418274},{"id":"https://openalex.org/C127313418","wikidata":"https://www.wikidata.org/wiki/Q1069","display_name":"Geology","level":0,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C165205528","wikidata":"https://www.wikidata.org/wiki/Q83371","display_name":"Seismology","level":1,"score":0.0},{"id":"https://openalex.org/C46141821","wikidata":"https://www.wikidata.org/wiki/Q209402","display_name":"Nuclear magnetic resonance","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"mag:2184828827","doi":null,"is_oa":false,"landing_page_url":"https://ieeexplore.ieee.org/abstract/document/4544105","pdf_url":null,"source":null,"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":null}],"best_oa_location":null,"sustainable_development_goals":[],"study_designs":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":0,"referenced_works":[],"related_works":["https://openalex.org/W2122214279","https://openalex.org/W4306888714","https://openalex.org/W2045169377","https://openalex.org/W2080973360","https://openalex.org/W4309757699","https://openalex.org/W2204313450","https://openalex.org/W2080850924","https://openalex.org/W2043899981","https://openalex.org/W4404678925","https://openalex.org/W2033802545"],"abstract_inverted_index":{"Inthispaper,":[0],"a":[1],"newtechnique":[2],"forstator":[3],"Then,a":[4],"new":[5],"inter-turn":[6,10],"faultindicator":[7],"willbe":[8],"winding":[9],"fault":[11,58],"detection":[12,30],"inPermanent":[13],"Magnetpresented.":[14],"Itisbasedontheinstantaneous":[15],"mechanical":[16,26],"Synchronous":[17],"Machines":[18],"isproposed.":[19],"Itconsists":[20],"of":[21,43],"poweranalysis.":[22],"Therearealotofworksintheliterature":[23],"extracting":[24],"the":[25],"power":[27],"secondharmoniconinter-turn":[28],"faults":[29],"forInduction":[31],"Machines.":[32,69],"A":[33],"component":[34],"whichappears":[35],"whenthemachine":[36],"isfaulty.":[37],"This":[38],"numberofthese":[39],"methods":[40],"arebased":[41],"ontheevaluation":[42],"harmonic":[44],"isprocessed":[45],"inordertoobtain":[46],"afault":[47],"indicator.":[48],"Itwillbeshownthattheamplitude":[49],"ofthisindicator":[50],"negative":[51,79],"andpositive":[52],"impedance":[53],"sequences":[54,80],"(2,7).But":[55],"depends":[56],"ontheinter-turn":[57],"severity.":[59],"Theproposedtheseapproaches":[60],"arenoteasily":[61],"transposable":[62],"on":[63],"technique":[64],"allows":[65],"detecting":[66],"thefault":[67],"inrealtimeanditsSynchronous":[68],"Indeed,":[70],"whenthiskindof":[71],"implementation":[72],"iseasy.":[73],"Theexperimental":[74],"results":[75],"showthe":[76],"machine":[77],"isunbalanced,":[78],"EMF":[81],"exist,":[82],"validity":[83],"oftheproposed":[84],"method.":[85],"sotheimpedance":[86],"evaluations":[87],"needtheevaluation":[88],"ofthe":[89],"IndexTerms-":[90],"Fault":[91],"diagnosis,":[92],"Inter-turn":[93],"fault,":[94],"PMSM,EMF.Weprefer":[95],"todevelop":[96],"amethod":[97],"exploiting":[98],"thefact":[99],"Health":[100],"monitoring.":[101]},"cited_by_api_url":"https://api.openalex.org/works?filter=cites:W2184828827","counts_by_year":[{"year":2017,"cited_by_count":1}],"updated_date":"2026-11-16T12:05:36.265796","created_date":"2016-06-24T00:00:00"}
