{"id":"https://openalex.org/W2180899145","doi":"https://doi.org/10.1063/1.4935308","title":"An absolute calibration method of an ethyl alcohol biosensor based on wavelength-modulated differential photothermal radiometry","display_name":"An absolute calibration method of an ethyl alcohol biosensor based on wavelength-modulated differential photothermal radiometry","alternate_titles":[],"publication_year":2015,"publication_date":"2015-11-01","ids":{"openalex":"https://openalex.org/W2180899145","doi":"https://doi.org/10.1063/1.4935308","mag":"2180899145","pmid":"https://pubmed.ncbi.nlm.nih.gov/26628164"},"language":"en","primary_location":{"id":"doi:10.1063/1.4935308","doi":"https://doi.org/10.1063/1.4935308","is_oa":false,"landing_page_url":"https://doi.org/10.1063/1.4935308","pdf_url":null,"source":{"id":"https://openalex.org/S31010182","display_name":"Review of Scientific Instruments","issn_l":"0034-6748","issn":["0034-6748","1089-7623","1527-2400"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["cwts-core","dongbi-c","jufo-1","ki-jl-1","medline","norway-1","poland-70","russia-white-list-2","vabb-shw"],"host_organization":"https://openalex.org/P4310320257","host_organization_name":"American Institute of Physics","host_organization_lineage":["https://openalex.org/P4310320257"],"host_organization_lineage_names":["American Institute of Physics"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Review of Scientific Instruments","raw_type":"journal-article"},"parent_works":[],"lineage":["https://openalex.org/W2180899145"],"child_works_count":0,"type":"article","is_traditional":true,"indexed_in":["crossref","pubmed"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5015069293","display_name":"Yi Jun Liu","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I185261750","display_name":"University of Toronto","ror":"https://ror.org/03dbr7087","country_code":"CA","type":"education","lineage":["https://openalex.org/I185261750"]}],"countries":["CA"],"is_corresponding":false,"contributor_roles":[],"raw_author_name":"Yi Jun Liu","raw_affiliation_strings":["University of Toronto 1 Department of Mechanical and Industrial Engineering, Center for Advanced Diffusion-Wave Technologies (CADIFT), , Toronto, Ontario M5S 3G8, Canada","University of Toronto 2 Institute of Biomaterials and Biomedical Engineering, , Toronto, Ontario M5S 3G9, Canada"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"University of Toronto 1 Department of Mechanical and Industrial Engineering, Center for Advanced Diffusion-Wave Technologies (CADIFT), , Toronto, Ontario M5S 3G8, Canada","institution_ids":["https://openalex.org/I185261750"]},{"raw_affiliation_string":"University of Toronto 2 Institute of Biomaterials and Biomedical Engineering, , Toronto, Ontario M5S 3G9, Canada","institution_ids":["https://openalex.org/I185261750"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5046121183","display_name":"Andreas Mandelis","orcid":"https://orcid.org/0000-0003-0625-8611","observed_orcids":["https://orcid.org/0000-0003-0625-8611"]},"institutions":[{"id":"https://openalex.org/I185261750","display_name":"University of Toronto","ror":"https://ror.org/03dbr7087","country_code":"CA","type":"education","lineage":["https://openalex.org/I185261750"]}],"countries":["CA"],"is_corresponding":false,"contributor_roles":[],"raw_author_name":"Andreas Mandelis","raw_affiliation_strings":["University of Toronto 1 Department of Mechanical and Industrial Engineering, Center for Advanced Diffusion-Wave Technologies (CADIFT), , Toronto, Ontario M5S 3G8, Canada","University of Toronto 2 Institute of Biomaterials and Biomedical Engineering, , Toronto, Ontario M5S 3G9, Canada"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"University of Toronto 1 Department of Mechanical and Industrial Engineering, Center for Advanced Diffusion-Wave Technologies (CADIFT), , Toronto, Ontario M5S 3G8, Canada","institution_ids":["https://openalex.org/I185261750"]},{"raw_affiliation_string":"University of Toronto 2 Institute of Biomaterials and Biomedical Engineering, , Toronto, Ontario M5S 3G9, Canada","institution_ids":["https://openalex.org/I185261750"]}]},{"author_position":"last","author":{"id":null,"display_name":"Xinxin Guo","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I185261750","display_name":"University of Toronto","ror":"https://ror.org/03dbr7087","country_code":"CA","type":"education","lineage":["https://openalex.org/I185261750"]}],"countries":["CA"],"is_corresponding":false,"contributor_roles":[],"raw_author_name":"Xinxin Guo","raw_affiliation_strings":["University of Toronto 1 Department of Mechanical and Industrial Engineering, Center for Advanced Diffusion-Wave Technologies (CADIFT), , Toronto, Ontario M5S 3G8, Canada"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"University of Toronto 1 Department of Mechanical and Industrial Engineering, Center for Advanced Diffusion-Wave Technologies (CADIFT), , Toronto, Ontario M5S 3G8, Canada","institution_ids":["https://openalex.org/I185261750"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":["https://openalex.org/I185261750"],"apc_list":null,"apc_paid":null,"fwci":0.3341,"has_fulltext":false,"cited_by_count":7,"citation_normalized_percentile":{"value":0.41834815,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":86,"max":95},"biblio":{"volume":"86","issue":"11","first_page":"115003","last_page":"115003"},"is_retracted":false,"is_pulled":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11111","display_name":"Spectroscopy and Laser Applications","score":0.7724999785423279,"subfield":{"id":"https://openalex.org/subfields/1607","display_name":"Spectroscopy"},"field":{"id":"https://openalex.org/fields/16","display_name":"Chemistry"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11111","display_name":"Spectroscopy and Laser Applications","score":0.7724999785423279,"subfield":{"id":"https://openalex.org/subfields/1607","display_name":"Spectroscopy"},"field":{"id":"https://openalex.org/fields/16","display_name":"Chemistry"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11324","display_name":"Spectroscopy Techniques in Biomedical and Chemical Research","score":0.1363999992609024,"subfield":{"id":"https://openalex.org/subfields/1304","display_name":"Biophysics"},"field":{"id":"https://openalex.org/fields/13","display_name":"Biochemistry, Genetics and Molecular Biology"},"domain":{"id":"https://openalex.org/domains/1","display_name":"Life Sciences"}},{"id":"https://openalex.org/T11856","display_name":"Thermography and Photoacoustic Techniques","score":0.03240000084042549,"subfield":{"id":"https://openalex.org/subfields/2211","display_name":"Mechanics of Materials"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/ethanol-biosensor","display_name":"ethanol biosensor","score":0.7879999876022339},{"id":"https://openalex.org/keywords/absolute-calibration","display_name":"absolute calibration","score":0.9380000233650208},{"id":"https://openalex.org/keywords/ignition-interlock","display_name":"ignition interlock","score":0.8880000114440918},{"id":"https://openalex.org/keywords/mid-infrared-absorption-spectroscopy","display_name":"mid-infrared absorption spectroscopy","score":0.6940000057220459}],"concepts":[{"id":"https://openalex.org/C160756335","wikidata":"https://www.wikidata.org/wiki/Q669391","display_name":"Biosensor","level":2,"score":0.801912784576416},{"id":"https://openalex.org/C165838908","wikidata":"https://www.wikidata.org/wiki/Q736777","display_name":"Calibration","level":2,"score":0.6232635378837585},{"id":"https://openalex.org/C192562407","wikidata":"https://www.wikidata.org/wiki/Q228736","display_name":"Materials science","level":0,"score":0.5886383652687073},{"id":"https://openalex.org/C87456703","wikidata":"https://www.wikidata.org/wiki/Q247760","display_name":"Radiometry","level":2,"score":0.5323026180267334},{"id":"https://openalex.org/C182606246","wikidata":"https://www.wikidata.org/wiki/Q7187926","display_name":"Photothermal therapy","level":2,"score":0.5197272300720215},{"id":"https://openalex.org/C120665830","wikidata":"https://www.wikidata.org/wiki/Q14620","display_name":"Optics","level":1,"score":0.5162310600280762},{"id":"https://openalex.org/C6260449","wikidata":"https://www.wikidata.org/wiki/Q41364","display_name":"Wavelength","level":2,"score":0.5002009868621826},{"id":"https://openalex.org/C2780161600","wikidata":"https://www.wikidata.org/wiki/Q153","display_name":"Ethanol","level":2,"score":0.4520324766635895},{"id":"https://openalex.org/C2779843651","wikidata":"https://www.wikidata.org/wiki/Q7390335","display_name":"SIGNAL (programming language)","level":2,"score":0.45109108090400696},{"id":"https://openalex.org/C125287762","wikidata":"https://www.wikidata.org/wiki/Q1758948","display_name":"Absorption (acoustics)","level":2,"score":0.4260566532611847},{"id":"https://openalex.org/C21200559","wikidata":"https://www.wikidata.org/wiki/Q7451068","display_name":"Sensitivity (control systems)","level":2,"score":0.42213377356529236},{"id":"https://openalex.org/C2781066024","wikidata":"https://www.wikidata.org/wiki/Q156","display_name":"Alcohol","level":2,"score":0.42163926362991333},{"id":"https://openalex.org/C49040817","wikidata":"https://www.wikidata.org/wiki/Q193091","display_name":"Optoelectronics","level":1,"score":0.3315780758857727},{"id":"https://openalex.org/C185592680","wikidata":"https://www.wikidata.org/wiki/Q2329","display_name":"Chemistry","level":0,"score":0.21323585510253906},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.13797613978385925},{"id":"https://openalex.org/C171250308","wikidata":"https://www.wikidata.org/wiki/Q11468","display_name":"Nanotechnology","level":1,"score":0.12404096126556396},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.09195542335510254},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C199360897","wikidata":"https://www.wikidata.org/wiki/Q9143","display_name":"Programming language","level":1,"score":0.0},{"id":"https://openalex.org/C178790620","wikidata":"https://www.wikidata.org/wiki/Q11351","display_name":"Organic chemistry","level":1,"score":0.0},{"id":"https://openalex.org/C55493867","wikidata":"https://www.wikidata.org/wiki/Q7094","display_name":"Biochemistry","level":1,"score":0.0},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.0},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.0}],"mesh":[{"descriptor_ui":"D000431","descriptor_name":"Ethanol","qualifier_ui":"Q000032","qualifier_name":"analysis","is_major_topic":true},{"descriptor_ui":"D002138","descriptor_name":"Calibration","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D008956","descriptor_name":"Models, Chemical","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D011874","descriptor_name":"Radiometry","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D011874","descriptor_name":"Radiometry","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":false},{"descriptor_ui":"D011874","descriptor_name":"Radiometry","qualifier_ui":"Q000592","qualifier_name":"standards","is_major_topic":false},{"descriptor_ui":"D015374","descriptor_name":"Biosensing Techniques","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":true},{"descriptor_ui":"D015374","descriptor_name":"Biosensing Techniques","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":true},{"descriptor_ui":"D015374","descriptor_name":"Biosensing Techniques","qualifier_ui":"Q000592","qualifier_name":"standards","is_major_topic":false}],"locations_count":2,"locations":[{"id":"doi:10.1063/1.4935308","doi":"https://doi.org/10.1063/1.4935308","is_oa":false,"landing_page_url":"https://doi.org/10.1063/1.4935308","pdf_url":null,"source":{"id":"https://openalex.org/S31010182","display_name":"Review of Scientific Instruments","issn_l":"0034-6748","issn":["0034-6748","1089-7623","1527-2400"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["cwts-core","dongbi-c","jufo-1","ki-jl-1","medline","norway-1","poland-70","russia-white-list-2","vabb-shw"],"host_organization":"https://openalex.org/P4310320257","host_organization_name":"American Institute of Physics","host_organization_lineage":["https://openalex.org/P4310320257"],"host_organization_lineage_names":["American Institute of Physics"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Review of Scientific Instruments","raw_type":"journal-article"},{"id":"pmid:26628164","doi":null,"is_oa":false,"landing_page_url":"https://pubmed.ncbi.nlm.nih.gov/26628164","pdf_url":null,"source":{"id":"https://openalex.org/S4306525036","display_name":"PubMed","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I1299303238","host_organization_name":"National Institutes of Health","host_organization_lineage":["https://openalex.org/I1299303238"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"The Review of scientific instruments","raw_type":"Journal Article"}],"best_oa_location":null,"sustainable_development_goals":[],"study_designs":[],"awards":[],"funders":[{"id":"https://openalex.org/F4320334593","display_name":"Natural Sciences and Engineering Research Council of Canada","ror":"https://ror.org/01h531d29"}],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":17,"referenced_works":["https://openalex.org/W40187424","https://openalex.org/W1987221958","https://openalex.org/W2011210465","https://openalex.org/W2020443322","https://openalex.org/W2021937809","https://openalex.org/W2035723609","https://openalex.org/W2065324067","https://openalex.org/W2069558618","https://openalex.org/W2075964398","https://openalex.org/W2092581039","https://openalex.org/W2092811028","https://openalex.org/W2097683070","https://openalex.org/W2118781706","https://openalex.org/W2122071975","https://openalex.org/W2143150256","https://openalex.org/W2163993689","https://openalex.org/W3217528490"],"related_works":["https://openalex.org/W2565047367","https://openalex.org/W2035723609","https://openalex.org/W2948477913","https://openalex.org/W2891839994","https://openalex.org/W2004242789","https://openalex.org/W1868963832","https://openalex.org/W2005012884","https://openalex.org/W2157961520","https://openalex.org/W2996619505","https://openalex.org/W1584323894"],"abstract_inverted_index":{"In":[0],"this":[1],"work,":[2],"laser-based":[3],"wavelength-modulated":[4],"differential":[5,30],"photothermal":[6],"radiometry":[7],"(WM-DPTR)":[8],"is":[9],"applied":[10],"to":[11,111],"develop":[12],"a":[13,29,103],"non-invasive":[14],"in-vehicle":[15],"alcohol":[16,72,90],"biosensor.":[17],"WM-DPTR":[18,50],"features":[19],"unprecedented":[20],"ethanol-specificity":[21],"and":[22,35,52,59,78,116],"sensitivity":[23],"by":[24],"suppressing":[25],"baseline":[26,36],"variations":[27],"through":[28],"measurement":[31],"near":[32],"the":[33,38,69,81],"peak":[34],"of":[37,85,114],"mid-infrared":[39],"ethanol":[40,60,82],"absorption":[41],"spectrum.":[42],"Biosensor":[43],"signal":[44],"calibration":[45],"curves":[46],"are":[47],"obtained":[48],"from":[49,53,63],"theory":[51],"measurements":[54],"in":[55,106,108],"human":[56],"blood":[57],"serum":[58],"solutions":[61],"diffused":[62],"skin.":[64],"The":[65,88],"results":[66],"demonstrate":[67],"that":[68,98],"WM-DPTR-based":[70],"calibrated":[71],"biosensor":[73,91],"can":[74,92],"achieve":[75],"high":[76],"precision":[77],"accuracy":[79],"for":[80],"concentration":[83],"range":[84],"0-100":[86],"mg/dl.":[87],"high-performance":[89],"be":[93,100],"incorporated":[94],"into":[95],"ignition":[96],"interlocks":[97],"could":[99],"fitted":[101],"as":[102],"universal":[104],"accessory":[105],"vehicles":[107],"an":[109],"effort":[110],"reduce":[112],"incidents":[113],"drinking":[115],"driving.":[117]},"cited_by_api_url":"https://api.openalex.org/works?filter=cites:W2180899145","counts_by_year":[{"year":2024,"cited_by_count":1},{"year":2022,"cited_by_count":1},{"year":2021,"cited_by_count":1},{"year":2019,"cited_by_count":1},{"year":2018,"cited_by_count":2},{"year":2016,"cited_by_count":1}],"updated_date":"2026-11-16T12:05:36.265796","created_date":"2016-06-24T00:00:00"}
