{"id":"https://openalex.org/W2170660880","doi":"https://doi.org/10.1109/arftg77.2011.6034558","title":"Evaluation of complex residual error in vector network analyzer measurement system in the range of millimeter-wave and submillimeter-wave frequencies","display_name":"Evaluation of complex residual error in vector network analyzer measurement system in the range of millimeter-wave and submillimeter-wave frequencies","alternate_titles":[],"publication_year":2011,"publication_date":"2011-06-01","ids":{"openalex":"https://openalex.org/W2170660880","doi":"https://doi.org/10.1109/arftg77.2011.6034558","mag":"2170660880"},"language":"en","primary_location":{"id":"doi:10.1109/arftg77.2011.6034558","doi":"https://doi.org/10.1109/arftg77.2011.6034558","is_oa":false,"landing_page_url":"https://doi.org/10.1109/arftg77.2011.6034558","pdf_url":null,"source":{"id":"https://openalex.org/S4306417708","display_name":"ARFTG Microwave Measurement Conference","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"77th ARFTG Microwave Measurement Conference","raw_type":"proceedings-article"},"parent_works":[],"lineage":["https://openalex.org/W2170660880"],"child_works_count":0,"type":"conference-paper","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5026725703","display_name":"Ryoko Kishikawa","orcid":"https://orcid.org/0000-0002-5545-4136","observed_orcids":["https://orcid.org/0000-0002-5545-4136"]},"institutions":[{"id":"https://openalex.org/I4405273829","display_name":"National Metrology Institute of Japan","ror":"https://ror.org/00j3eeb74","country_code":"JP","type":"government","lineage":["https://openalex.org/I4405273829","https://openalex.org/I73613424"]},{"id":"https://openalex.org/I73613424","display_name":"National Institute of Advanced Industrial Science and Technology","ror":"https://ror.org/01703db54","country_code":"JP","type":"government","lineage":["https://openalex.org/I73613424"]}],"countries":["JP"],"is_corresponding":false,"raw_author_name":"Ryoko Kishikawa","raw_affiliation_strings":["National Metrology Institute of Japan, National Institute of Advanced Industrial Science and Technology, Tsukuba, Ibaraki, Japan"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"National Metrology Institute of Japan, National Institute of Advanced Industrial Science and Technology, Tsukuba, Ibaraki, Japan","institution_ids":["https://openalex.org/I4405273829","https://openalex.org/I73613424"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5031714807","display_name":"Masahiro Horibe","orcid":"https://orcid.org/0000-0002-1193-607X","observed_orcids":["https://orcid.org/0000-0002-1193-607X"]},"institutions":[{"id":"https://openalex.org/I4405273829","display_name":"National Metrology Institute of Japan","ror":"https://ror.org/00j3eeb74","country_code":"JP","type":"government","lineage":["https://openalex.org/I4405273829","https://openalex.org/I73613424"]},{"id":"https://openalex.org/I73613424","display_name":"National Institute of Advanced Industrial Science and Technology","ror":"https://ror.org/01703db54","country_code":"JP","type":"government","lineage":["https://openalex.org/I73613424"]}],"countries":["JP"],"is_corresponding":false,"raw_author_name":"Masahiro Horibe","raw_affiliation_strings":["National Metrology Institute of Japan, National Institute of Advanced Industrial Science and Technology, Tsukuba, Ibaraki, Japan"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"National Metrology Institute of Japan, National Institute of Advanced Industrial Science and Technology, Tsukuba, Ibaraki, Japan","institution_ids":["https://openalex.org/I4405273829","https://openalex.org/I73613424"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5071891582","display_name":"Masaaki Shida","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I4405273829","display_name":"National Metrology Institute of Japan","ror":"https://ror.org/00j3eeb74","country_code":"JP","type":"government","lineage":["https://openalex.org/I4405273829","https://openalex.org/I73613424"]},{"id":"https://openalex.org/I73613424","display_name":"National Institute of Advanced Industrial Science and Technology","ror":"https://ror.org/01703db54","country_code":"JP","type":"government","lineage":["https://openalex.org/I73613424"]}],"countries":["JP"],"is_corresponding":false,"raw_author_name":"Masaaki Shida","raw_affiliation_strings":["National Metrology Institute of Japan, National Institute of Advanced Industrial Science and Technology, Tsukuba, Ibaraki, Japan"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"National Metrology Institute of Japan, National Institute of Advanced Industrial Science and Technology, Tsukuba, Ibaraki, Japan","institution_ids":["https://openalex.org/I4405273829","https://openalex.org/I73613424"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":2,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.4237,"has_fulltext":false,"cited_by_count":4,"citation_normalized_percentile":{"value":0.46083656,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":88,"max":96},"biblio":{"volume":null,"issue":null,"first_page":"1","last_page":"7"},"is_retracted":false,"is_pulled":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11607","display_name":"Microwave and Dielectric Measurement Techniques","score":0.986299991607666,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11607","display_name":"Microwave and Dielectric Measurement Techniques","score":0.986299991607666,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12300","display_name":"Advanced Electrical Measurement Techniques","score":0.004600000102072954,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10262","display_name":"Microwave Engineering and Waveguides","score":0.003800000064074993,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/vector-network-analyzer","display_name":"vector network analyzer","score":0.9110000133514404},{"id":"https://openalex.org/keywords/measurement-error-analysis","display_name":"measurement error analysis","score":0.49000000953674316},{"id":"https://openalex.org/keywords/millimeter-wave","display_name":"millimeter wave","score":0.6620000004768372},{"id":"https://openalex.org/keywords/submillimeter-wave","display_name":"submillimeter waves","score":0.9990000128746033},{"id":"https://openalex.org/keywords/coaxial-transmission-line","display_name":"coaxial transmission line","score":0.7129999995231628},{"id":"https://openalex.org/keywords/waveguide-transmission-lines","display_name":"waveguide transmission lines","score":0.781000018119812},{"id":"https://openalex.org/keywords/s-parameters","display_name":"S-parameters","score":0.6899999976158142},{"id":"https://openalex.org/keywords/si-traceability","display_name":"SI traceability","score":0.6819999814033508}],"concepts":[{"id":"https://openalex.org/C195766429","wikidata":"https://www.wikidata.org/wiki/Q394","display_name":"Metrology","level":2,"score":0.6904243230819702},{"id":"https://openalex.org/C99101257","wikidata":"https://www.wikidata.org/wiki/Q1529374","display_name":"Network analyzer (electrical)","level":2,"score":0.6789733171463013},{"id":"https://openalex.org/C51221625","wikidata":"https://www.wikidata.org/wiki/Q1751466","display_name":"Coaxial","level":2,"score":0.6683955192565918},{"id":"https://openalex.org/C109792285","wikidata":"https://www.wikidata.org/wiki/Q174789","display_name":"Millimeter","level":2,"score":0.6201894879341125},{"id":"https://openalex.org/C195266298","wikidata":"https://www.wikidata.org/wiki/Q2165620","display_name":"Scattering parameters","level":2,"score":0.6169698238372803},{"id":"https://openalex.org/C44838205","wikidata":"https://www.wikidata.org/wiki/Q127995","display_name":"Microwave","level":2,"score":0.6107366681098938},{"id":"https://openalex.org/C45764600","wikidata":"https://www.wikidata.org/wiki/Q570342","display_name":"Extremely high frequency","level":2,"score":0.5898933410644531},{"id":"https://openalex.org/C120665830","wikidata":"https://www.wikidata.org/wiki/Q14620","display_name":"Optics","level":1,"score":0.5889900326728821},{"id":"https://openalex.org/C155512373","wikidata":"https://www.wikidata.org/wiki/Q287450","display_name":"Residual","level":2,"score":0.567585289478302},{"id":"https://openalex.org/C200687136","wikidata":"https://www.wikidata.org/wiki/Q11233438","display_name":"Waveguide","level":2,"score":0.5490435361862183},{"id":"https://openalex.org/C33441834","wikidata":"https://www.wikidata.org/wiki/Q693004","display_name":"Transmission line","level":2,"score":0.5041614770889282},{"id":"https://openalex.org/C137209882","wikidata":"https://www.wikidata.org/wiki/Q1403517","display_name":"Measurement uncertainty","level":2,"score":0.4483187198638916},{"id":"https://openalex.org/C133386390","wikidata":"https://www.wikidata.org/wiki/Q184996","display_name":"Dielectric","level":2,"score":0.4188840091228485},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.3785625398159027},{"id":"https://openalex.org/C192562407","wikidata":"https://www.wikidata.org/wiki/Q228736","display_name":"Materials science","level":0,"score":0.37746405601501465},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.2567914128303528},{"id":"https://openalex.org/C49040817","wikidata":"https://www.wikidata.org/wiki/Q193091","display_name":"Optoelectronics","level":1,"score":0.22808480262756348},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.18873730301856995},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.18399661779403687},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.17753314971923828},{"id":"https://openalex.org/C11413529","wikidata":"https://www.wikidata.org/wiki/Q8366","display_name":"Algorithm","level":1,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/arftg77.2011.6034558","doi":"https://doi.org/10.1109/arftg77.2011.6034558","is_oa":false,"landing_page_url":"https://doi.org/10.1109/arftg77.2011.6034558","pdf_url":null,"source":{"id":"https://openalex.org/S4306417708","display_name":"ARFTG Microwave Measurement Conference","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"77th ARFTG Microwave Measurement Conference","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[],"study_designs":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":12,"referenced_works":["https://openalex.org/W2041820778","https://openalex.org/W2099471856","https://openalex.org/W2121284122","https://openalex.org/W2125420972","https://openalex.org/W2158451083","https://openalex.org/W2158820649","https://openalex.org/W2496571228","https://openalex.org/W2534243319","https://openalex.org/W2537692582","https://openalex.org/W2552758358","https://openalex.org/W2808011227","https://openalex.org/W4230331417"],"related_works":["https://openalex.org/W2373880276","https://openalex.org/W2577729934","https://openalex.org/W2130620549","https://openalex.org/W4407476427","https://openalex.org/W2064344706","https://openalex.org/W2095830355","https://openalex.org/W2168303205","https://openalex.org/W2154456406","https://openalex.org/W3146575488","https://openalex.org/W1531001889"],"abstract_inverted_index":{"This":[0],"paper":[1],"describes":[2],"a":[3,85],"technique":[4,32],"for":[5,41,63,81],"the":[6,22,64,69],"evaluation":[7],"of":[8,24,38,46,73],"complex":[9],"residual":[10,77],"errors":[11],"in":[12,21],"coaxial":[13,47,87],"and":[14,27,51,90,94],"waveguide":[15,52,96],"vector":[16],"network":[17],"analyzer":[18],"(VNA)":[19],"measurements":[20,83],"range":[23],"microwave,":[25],"millimeter":[26],"submillimeter":[28],"wave":[29],"frequencies.":[30],"The":[31],"is":[33],"based":[34],"on":[35],"reference":[36],"values":[37,56],"scattering":[39],"parameters":[40],"transmission":[42,66],"line":[43,88],"standards":[44],"consisting":[45],"air":[48],"dielectric":[49],"lines":[50,67],"standard":[53,65],"sections.":[54],"Reference":[55],"traceable":[57],"to":[58,99],"SI-base":[59],"units":[60],"were":[61],"calibrated":[62],"by":[68],"National":[70],"Metrology":[71],"Institute":[72],"Japan":[74],"(NMIJ).":[75],"Complex":[76],"analyses":[78],"are":[79],"shown":[80],"VNA":[82],"with":[84,91],"PC-7":[86],"system":[89],"WR-15,":[92],"WR-10":[93],"WR-3":[95],"systems":[97],"up":[98],"330":[100],"GHz.":[101]},"cited_by_api_url":"https://api.openalex.org/works?filter=cites:W2170660880","counts_by_year":[{"year":2018,"cited_by_count":1},{"year":2016,"cited_by_count":2},{"year":2012,"cited_by_count":1}],"updated_date":"2026-11-16T12:05:36.265796","created_date":"2016-06-24T00:00:00"}
