{"id":"https://openalex.org/W2170357635","doi":"https://doi.org/10.1109/eem.2011.5953038","title":"Optimization of voltage regulators settings and transformer tap zones in distribution systems with great load variation using distribution automation and the smart grids initiatives","display_name":"Optimization of voltage regulators settings and transformer tap zones in distribution systems with great load variation using distribution automation and the smart grids initiatives","publication_year":2011,"publication_date":"2011-05-01","ids":{"openalex":"https://openalex.org/W2170357635","doi":"https://doi.org/10.1109/eem.2011.5953038","mag":"2170357635"},"language":"en","primary_location":{"id":"doi:10.1109/eem.2011.5953038","doi":"https://doi.org/10.1109/eem.2011.5953038","is_oa":false,"landing_page_url":"https://doi.org/10.1109/eem.2011.5953038","pdf_url":null,"source":{"id":"https://openalex.org/S4363608161","display_name":"International Conference on the European Energy Market (EEM)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2011 8th International Conference on the European Energy Market (EEM)","raw_type":"proceedings-article"},"parent_works":[],"lineage":["https://openalex.org/W2170357635"],"child_works_count":0,"type":"conference-paper","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5022836310","display_name":"Paulo Pereira","orcid":"https://orcid.org/0000-0001-9599-2476","observed_orcids":["https://orcid.org/0000-0001-9599-2476"]},"institutions":[{"id":"https://openalex.org/I33501960","display_name":"Universidade Federal de Santa Maria","ror":"https://ror.org/01b78mz79","country_code":"BR","type":"education","lineage":["https://openalex.org/I33501960"]}],"countries":["BR"],"is_corresponding":false,"raw_author_name":"Paulo Pereira","raw_affiliation_strings":["UFSM Federal University of Santa Maria, Santa Maria, Rio Grande do Sul, Brazil"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"UFSM Federal University of Santa Maria, Santa Maria, Rio Grande do Sul, Brazil","institution_ids":["https://openalex.org/I33501960"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5024073219","display_name":"Luciane Neves Canha","orcid":"https://orcid.org/0000-0002-2195-6015","observed_orcids":["https://orcid.org/0000-0002-2195-6015"]},"institutions":[{"id":"https://openalex.org/I33501960","display_name":"Universidade Federal de Santa Maria","ror":"https://ror.org/01b78mz79","country_code":"BR","type":"education","lineage":["https://openalex.org/I33501960"]}],"countries":["BR"],"is_corresponding":false,"raw_author_name":"Luciane Canha","raw_affiliation_strings":["UFSM Federal University of Santa Maria, Santa Maria, Rio Grande do Sul, Brazil"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"UFSM Federal University of Santa Maria, Santa Maria, Rio Grande do Sul, Brazil","institution_ids":["https://openalex.org/I33501960"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5007111243","display_name":"Rafael Gressler Milbradt","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I33501960","display_name":"Universidade Federal de Santa Maria","ror":"https://ror.org/01b78mz79","country_code":"BR","type":"education","lineage":["https://openalex.org/I33501960"]}],"countries":["BR"],"is_corresponding":false,"raw_author_name":"Rafael Milbradt","raw_affiliation_strings":["UFSM Federal University of Santa Maria, Santa Maria, Rio Grande do Sul, Brazil"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"UFSM Federal University of Santa Maria, Santa Maria, Rio Grande do Sul, Brazil","institution_ids":["https://openalex.org/I33501960"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5010879861","display_name":"Alzenira da Rosa Abaide","orcid":"https://orcid.org/0000-0003-1043-1608","observed_orcids":["https://orcid.org/0000-0003-1043-1608"]},"institutions":[{"id":"https://openalex.org/I33501960","display_name":"Universidade Federal de Santa Maria","ror":"https://ror.org/01b78mz79","country_code":"BR","type":"education","lineage":["https://openalex.org/I33501960"]}],"countries":["BR"],"is_corresponding":false,"raw_author_name":"Alzenira Abaide","raw_affiliation_strings":["UFSM Federal University of Santa Maria, Santa Maria, Rio Grande do Sul, Brazil"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"UFSM Federal University of Santa Maria, Santa Maria, Rio Grande do Sul, Brazil","institution_ids":["https://openalex.org/I33501960"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5113529990","display_name":"Sandro M. Schmaedecke","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I4210099365","display_name":"Governo do Estado do Rio Grande do Sul","ror":"https://ror.org/00jdxsj17","country_code":"BR","type":"government","lineage":["https://openalex.org/I4210099365"]}],"countries":["BR"],"is_corresponding":false,"raw_author_name":"Sandro Schmaedecke","raw_affiliation_strings":["CEEE-D-State Company of Electric Power Distribution of Rio Grande do Sul, Porto Alegre, Rio Grande do Sul, Brazil"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"CEEE-D-State Company of Electric Power Distribution of Rio Grande do Sul, Porto Alegre, Rio Grande do Sul, Brazil","institution_ids":["https://openalex.org/I4210099365"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5056435988","display_name":"Gustavo Arend","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I4210099365","display_name":"Governo do Estado do Rio Grande do Sul","ror":"https://ror.org/00jdxsj17","country_code":"BR","type":"government","lineage":["https://openalex.org/I4210099365"]}],"countries":["BR"],"is_corresponding":false,"raw_author_name":"Gustavo Arend","raw_affiliation_strings":["CEEE-D-State Company of Electric Power Distribution of Rio Grande do Sul, Porto Alegre, Rio Grande do Sul, Brazil"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"CEEE-D-State Company of Electric Power Distribution of Rio Grande do Sul, Porto Alegre, Rio Grande do Sul, Brazil","institution_ids":["https://openalex.org/I4210099365"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5067683934","display_name":"Ederson Pereira Madruga","orcid":"https://orcid.org/0000-0003-0476-4772","observed_orcids":["https://orcid.org/0000-0003-0476-4772"]},"institutions":[{"id":"https://openalex.org/I33501960","display_name":"Universidade Federal de Santa Maria","ror":"https://ror.org/01b78mz79","country_code":"BR","type":"education","lineage":["https://openalex.org/I33501960"]}],"countries":["BR"],"is_corresponding":false,"raw_author_name":"Ederson Madruga","raw_affiliation_strings":["UFSM Federal University of Santa Maria, Santa Maria, Rio Grande do Sul, Brazil"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"UFSM Federal University of Santa Maria, Santa Maria, Rio Grande do Sul, Brazil","institution_ids":["https://openalex.org/I33501960"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":2,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":3.3893,"has_fulltext":false,"cited_by_count":15,"citation_normalized_percentile":{"value":0.92470953,"is_in_top_1_percent":false,"is_in_top_10_percent":true},"cited_by_percentile_year":{"min":88,"max":97},"biblio":{"volume":null,"issue":null,"first_page":"365","last_page":"369"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10454","display_name":"Optimal Power Flow Distribution","score":0.86080002784729,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10454","display_name":"Optimal Power Flow Distribution","score":0.86080002784729,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12451","display_name":"Smart Grid and Power Systems","score":0.11999999731779099,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10573","display_name":"Power Quality and Harmonics","score":0.009499999694526196,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/voltage-regulator","display_name":"voltage regulator","score":0.8140000104904175},{"id":"https://openalex.org/keywords/transformer-tap-settings","display_name":"transformer tap settings","score":0.8550000190734863},{"id":"https://openalex.org/keywords/distribution-systems","display_name":"distribution systems","score":0.8149999976158142},{"id":"https://openalex.org/keywords/voltage-control","display_name":"voltage regulation","score":0.7480000257492065},{"id":"https://openalex.org/keywords/distribution-automation","display_name":"distribution automation","score":0.734000027179718},{"id":"https://openalex.org/keywords/smart-grid","display_name":"smart grid","score":0.9819999933242798},{"id":"https://openalex.org/keywords/load-variation","display_name":"load variation","score":0.9190000295639038},{"id":"https://openalex.org/keywords/voltage-quality","display_name":"voltage quality","score":0.7409999966621399}],"concepts":[{"id":"https://openalex.org/C115901376","wikidata":"https://www.wikidata.org/wiki/Q184199","display_name":"Automation","level":2,"score":0.6672230958938599},{"id":"https://openalex.org/C66322947","wikidata":"https://www.wikidata.org/wiki/Q11658","display_name":"Transformer","level":3,"score":0.6194053888320923},{"id":"https://openalex.org/C10558101","wikidata":"https://www.wikidata.org/wiki/Q689855","display_name":"Smart grid","level":2,"score":0.6057528257369995},{"id":"https://openalex.org/C196226539","wikidata":"https://www.wikidata.org/wiki/Q7940752","display_name":"Voltage regulation","level":3,"score":0.5792279243469238},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.5646361112594604},{"id":"https://openalex.org/C122940293","wikidata":"https://www.wikidata.org/wiki/Q1755966","display_name":"Tap changer","level":4,"score":0.5160622000694275},{"id":"https://openalex.org/C117323899","wikidata":"https://www.wikidata.org/wiki/Q1907989","display_name":"Distribution transformer","level":4,"score":0.48044320940971375},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.46939247846603394},{"id":"https://openalex.org/C544738498","wikidata":"https://www.wikidata.org/wiki/Q861135","display_name":"Distributed generation","level":3,"score":0.439385324716568},{"id":"https://openalex.org/C2779530757","wikidata":"https://www.wikidata.org/wiki/Q1207505","display_name":"Quality (philosophy)","level":2,"score":0.43627089262008667},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.40644800662994385},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.3840784430503845},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.3656163811683655},{"id":"https://openalex.org/C188573790","wikidata":"https://www.wikidata.org/wiki/Q12705","display_name":"Renewable energy","level":2,"score":0.18960285186767578},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.1000012457370758},{"id":"https://openalex.org/C111472728","wikidata":"https://www.wikidata.org/wiki/Q9471","display_name":"Epistemology","level":1,"score":0.0},{"id":"https://openalex.org/C138885662","wikidata":"https://www.wikidata.org/wiki/Q5891","display_name":"Philosophy","level":0,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/eem.2011.5953038","doi":"https://doi.org/10.1109/eem.2011.5953038","is_oa":false,"landing_page_url":"https://doi.org/10.1109/eem.2011.5953038","pdf_url":null,"source":{"id":"https://openalex.org/S4363608161","display_name":"International Conference on the European Energy Market (EEM)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2011 8th International Conference on the European Energy Market (EEM)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/9","display_name":"Industry, innovation and infrastructure","score":1.0},{"id":"https://metadata.un.org/sdg/7","display_name":"Affordable and clean energy","score":0.9853000044822693}],"study_designs":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":5,"referenced_works":["https://openalex.org/W1541786028","https://openalex.org/W2011385388","https://openalex.org/W2494074628","https://openalex.org/W2760001642","https://openalex.org/W6632345154"],"related_works":["https://openalex.org/W2760001642","https://openalex.org/W4415539546","https://openalex.org/W2011543148","https://openalex.org/W2171836942","https://openalex.org/W7199599214","https://openalex.org/W2777561963","https://openalex.org/W2086554304","https://openalex.org/W2565280663","https://openalex.org/W2603909306"],"abstract_inverted_index":{"The":[0],"efficiency,":[1],"useful":[2],"life":[3],"and":[4,32,66,71,118],"proper":[5],"functioning":[6],"of":[7,15,21,64,68,87,95,98,114],"electrical":[8],"devices":[9],"directly":[10],"depend":[11],"on":[12],"the":[13,19,24,30,36,52,76,85,88,93,96,99,103,115,120],"quality":[14,113],"energy":[16,22],"supplied.":[17],"Moreover,":[18],"supply":[20],"within":[23],"adequate":[25,48],"limits":[26],"is":[27,107],"necessary":[28],"for":[29],"economic":[31],"social":[33],"development":[34],"in":[35,42,58,102],"regions":[37],"served.":[38],"Given":[39],"these":[40],"factors,":[41],"order":[43],"to":[44,79,92,109],"improve":[45],"quality,":[46],"ensure":[47],"voltage":[49,61,100],"levels":[50],"over":[51],"distribution":[53,55,104],"networks,":[54],"companies":[56],"invest":[57],"system":[59],"improvements,":[60],"regulators,":[62],"exchange":[63],"conductors":[65],"construction":[67],"new":[69],"feeders":[70],"substations.":[72],"In":[73],"this":[74],"paper":[75],"authors":[77],"intend":[78],"present":[80],"a":[81,111],"methodology":[82],"that":[83],"uses":[84],"potential":[86],"smart":[89],"grids":[90],"applied":[91],"increase":[94],"efficiency":[97],"control":[101],"systems.":[105],"It":[106],"intended":[108],"reach":[110],"better":[112],"rendered":[116],"services":[117],"consequently":[119],"customers'":[121],"larger":[122],"satisfaction.":[123]},"counts_by_year":[{"year":2023,"cited_by_count":1},{"year":2021,"cited_by_count":3},{"year":2017,"cited_by_count":1},{"year":2016,"cited_by_count":2},{"year":2014,"cited_by_count":1},{"year":2013,"cited_by_count":4},{"year":2012,"cited_by_count":3}],"updated_date":"2026-11-14T11:04:58.165337","created_date":"2016-06-24T00:00:00"}
