{"id":"https://openalex.org/W2167753191","doi":"https://doi.org/10.1049/iet-epa.2010.0272","title":"Online fault-detecting scheme of an inverter-fed permanent magnet synchronous motor under stator winding shorted turn and inverter switch open","display_name":"Online fault-detecting scheme of an inverter-fed permanent magnet synchronous motor under stator winding shorted turn and inverter switch open","alternate_titles":[],"publication_year":2011,"publication_date":"2011-07-05","ids":{"openalex":"https://openalex.org/W2167753191","doi":"https://doi.org/10.1049/iet-epa.2010.0272","mag":"2167753191"},"language":"en","primary_location":{"id":"doi:10.1049/iet-epa.2010.0272","doi":"https://doi.org/10.1049/iet-epa.2010.0272","is_oa":false,"landing_page_url":"https://doi.org/10.1049/iet-epa.2010.0272","pdf_url":null,"source":{"id":"https://openalex.org/S3026325","display_name":"IET Electric Power Applications","issn_l":"1751-8660","issn":["1751-8660","1751-8679"],"is_oa":false,"is_in_doaj":true,"is_core":true,"listed_in":["cwts-core","doaj","dongbi-d","jufo-1","norway-1","oarl","poland-100","russia-white-list-2","vabb-shw"],"host_organization":"https://openalex.org/P4310311714","host_organization_name":"Institution of Engineering and Technology","host_organization_lineage":["https://openalex.org/P4310311714"],"host_organization_lineage_names":["Institution of Engineering and Technology"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IET Electric Power Applications","raw_type":"journal-article"},"parent_works":[],"lineage":["https://openalex.org/W2167753191"],"child_works_count":0,"type":"article","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5034084553","display_name":"Kyeong\u2010Hwa Kim","orcid":"https://orcid.org/0000-0001-5251-6322","observed_orcids":["https://orcid.org/0000-0001-5251-6322"]},"institutions":[{"id":"https://openalex.org/I118373667","display_name":"Seoul National University of Science and Technology","ror":"https://ror.org/00chfja07","country_code":"KR","type":"education","lineage":["https://openalex.org/I118373667"]}],"countries":["KR"],"is_corresponding":false,"contributor_roles":[],"raw_author_name":"K.-H. Kim","raw_affiliation_strings":["Department of Electrical Engineering, Seoul National University of Science and Technology, 172, Gongreung 2-Dong, Nowon-Gu, Seoul, 139-743, Korea"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Electrical Engineering, Seoul National University of Science and Technology, 172, Gongreung 2-Dong, Nowon-Gu, Seoul, 139-743, Korea","institution_ids":["https://openalex.org/I118373667"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5078264929","display_name":"Bon-Gwan Gu","orcid":"https://orcid.org/0000-0003-1436-6444","observed_orcids":["https://orcid.org/0000-0003-1436-6444"]},"institutions":[{"id":"https://openalex.org/I4210131650","display_name":"Korea Electronics Technology Institute","ror":"https://ror.org/039k6f508","country_code":"KR","type":"facility","lineage":["https://openalex.org/I2801339556","https://openalex.org/I4210089395","https://openalex.org/I4210131650"]}],"countries":["KR"],"is_corresponding":false,"contributor_roles":[],"raw_author_name":"B.-G. Gu","raw_affiliation_strings":["Intelligent Mechatronics Research Center, Korea Electronics Technology Institute, 203-101 Techno-park, Yakdae-dong, Wonmi-gu, Bucheon, Gyeonggi-do 420-140, Korea"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Intelligent Mechatronics Research Center, Korea Electronics Technology Institute, 203-101 Techno-park, Yakdae-dong, Wonmi-gu, Bucheon, Gyeonggi-do 420-140, Korea","institution_ids":["https://openalex.org/I4210131650"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5108516664","display_name":"In-Soung Jung","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I4210131650","display_name":"Korea Electronics Technology Institute","ror":"https://ror.org/039k6f508","country_code":"KR","type":"facility","lineage":["https://openalex.org/I2801339556","https://openalex.org/I4210089395","https://openalex.org/I4210131650"]}],"countries":["KR"],"is_corresponding":false,"contributor_roles":[],"raw_author_name":"I.-S. Jung","raw_affiliation_strings":["Intelligent Mechatronics Research Center, Korea Electronics Technology Institute, 203-101 Techno-park, Yakdae-dong, Wonmi-gu, Bucheon, Gyeonggi-do 420-140, Korea"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Intelligent Mechatronics Research Center, Korea Electronics Technology Institute, 203-101 Techno-park, Yakdae-dong, Wonmi-gu, Bucheon, Gyeonggi-do 420-140, Korea","institution_ids":["https://openalex.org/I4210131650"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":2,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":{"value":2880,"currency":"USD","value_usd":2880},"apc_paid":null,"fwci":4.618,"has_fulltext":false,"cited_by_count":49,"reviewed_by_count":0,"citation_normalized_percentile":{"value":0.9379492,"is_in_top_1_percent":false,"is_in_top_10_percent":true},"cited_by_percentile_year":{"min":92,"max":98},"biblio":{"volume":"5","issue":"6","first_page":"529","last_page":"539"},"is_retracted":false,"is_pulled":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10220","display_name":"Machine Fault Diagnosis Techniques","score":0.5845000147819519,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10220","display_name":"Machine Fault Diagnosis Techniques","score":0.5845000147819519,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10504","display_name":"Sensorless Control of Electric Motors","score":0.2289000004529953,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10278","display_name":"Electric Motor Design and Analysis","score":0.13040000200271606,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/fault-detection","display_name":"fault detection","score":0.9070000052452087},{"id":"https://openalex.org/keywords/permanent-magnet-synchronous-motor","display_name":"permanent magnet synchronous motor","score":0.9929999709129333},{"id":"https://openalex.org/keywords/inverter-fed-drives","display_name":"inverter-fed drives","score":0.9150000214576721},{"id":"https://openalex.org/keywords/second-harmonic","display_name":"second harmonic","score":0.7770000100135803},{"id":"https://openalex.org/keywords/q-axis-current","display_name":"q-axis current","score":0.968999981880188},{"id":"https://openalex.org/keywords/linear-interpolation","display_name":"linear interpolation","score":0.7540000081062317},{"id":"https://openalex.org/keywords/fault-source-identification","display_name":"fault source identification","score":0.7559999823570251},{"id":"https://openalex.org/keywords/phase-current-waveform","display_name":"phase current waveform","score":0.8659999966621399},{"id":"https://openalex.org/keywords/online-monitoring","display_name":"online monitoring","score":0.550000011920929}],"concepts":[{"id":"https://openalex.org/C11190779","wikidata":"https://www.wikidata.org/wiki/Q664575","display_name":"Inverter","level":3,"score":0.7177054286003113},{"id":"https://openalex.org/C2776529397","wikidata":"https://www.wikidata.org/wiki/Q190312","display_name":"Stator","level":2,"score":0.7013698220252991},{"id":"https://openalex.org/C175551986","wikidata":"https://www.wikidata.org/wiki/Q47089","display_name":"Fault (geology)","level":2,"score":0.6975735425949097},{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.6469547748565674},{"id":"https://openalex.org/C127934551","wikidata":"https://www.wikidata.org/wiki/Q1148098","display_name":"Harmonic","level":2,"score":0.6034923791885376},{"id":"https://openalex.org/C197424946","wikidata":"https://www.wikidata.org/wiki/Q1165717","display_name":"Waveform","level":3,"score":0.5627143979072571},{"id":"https://openalex.org/C152745839","wikidata":"https://www.wikidata.org/wiki/Q5438153","display_name":"Fault detection and isolation","level":3,"score":0.5382468700408936},{"id":"https://openalex.org/C21267803","wikidata":"https://www.wikidata.org/wiki/Q5438159","display_name":"Fault indicator","level":4,"score":0.49011144042015076},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.48054105043411255},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.3996482491493225},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.35337263345718384},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.3211703300476074},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.19661778211593628},{"id":"https://openalex.org/C172707124","wikidata":"https://www.wikidata.org/wiki/Q423488","display_name":"Actuator","level":2,"score":0.07963579893112183},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.07863488793373108},{"id":"https://openalex.org/C24890656","wikidata":"https://www.wikidata.org/wiki/Q82811","display_name":"Acoustics","level":1,"score":0.0754653811454773},{"id":"https://openalex.org/C127313418","wikidata":"https://www.wikidata.org/wiki/Q1069","display_name":"Geology","level":0,"score":0.0},{"id":"https://openalex.org/C165205528","wikidata":"https://www.wikidata.org/wiki/Q83371","display_name":"Seismology","level":1,"score":0.0},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.0},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1049/iet-epa.2010.0272","doi":"https://doi.org/10.1049/iet-epa.2010.0272","is_oa":false,"landing_page_url":"https://doi.org/10.1049/iet-epa.2010.0272","pdf_url":null,"source":{"id":"https://openalex.org/S3026325","display_name":"IET Electric Power Applications","issn_l":"1751-8660","issn":["1751-8660","1751-8679"],"is_oa":false,"is_in_doaj":true,"is_core":true,"listed_in":["cwts-core","doaj","dongbi-d","jufo-1","norway-1","oarl","poland-100","russia-white-list-2","vabb-shw"],"host_organization":"https://openalex.org/P4310311714","host_organization_name":"Institution of Engineering and Technology","host_organization_lineage":["https://openalex.org/P4310311714"],"host_organization_lineage_names":["Institution of Engineering and Technology"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IET Electric Power Applications","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/9","score":0.4943999946117401,"display_name":"Industry, innovation and infrastructure"}],"study_designs":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":22,"referenced_works":["https://openalex.org/W1500685872","https://openalex.org/W2010300984","https://openalex.org/W2026753505","https://openalex.org/W2040432521","https://openalex.org/W2041889229","https://openalex.org/W2096933492","https://openalex.org/W2103692342","https://openalex.org/W2112312998","https://openalex.org/W2117171612","https://openalex.org/W2120061047","https://openalex.org/W2122360919","https://openalex.org/W2129135438","https://openalex.org/W2131789431","https://openalex.org/W2139853183","https://openalex.org/W2153412203","https://openalex.org/W2154152725","https://openalex.org/W2158499370","https://openalex.org/W2162087833","https://openalex.org/W2164804984","https://openalex.org/W2171233586","https://openalex.org/W2572727817","https://openalex.org/W4239795001"],"related_works":["https://openalex.org/W2047798178","https://openalex.org/W2121565094","https://openalex.org/W2334956596","https://openalex.org/W7118007711","https://openalex.org/W3007958591","https://openalex.org/W2084612175","https://openalex.org/W2979404397","https://openalex.org/W2040432521","https://openalex.org/W2145167828","https://openalex.org/W2020032342"],"abstract_inverted_index":{"To":[0,111],"detect":[1],"faults":[2,15],"in":[3,16,44,58,65,83,128],"an":[4,23,66,155],"inverter-fed":[5],"permanent":[6],"magnet":[7],"synchronous":[8],"motor":[9,29,123],"drive":[10,89],"under":[11],"the":[12,40,48,73,84,87,92,96,107,113,116,129,158,165,173],"circumstance":[13],"having":[14],"a":[17,103,121],"stator":[18,130],"winding":[19,131],"and":[20,47,142],"inverter":[21],"switch,":[22],"online":[24],"basis":[25],"fault-detecting":[26],"scheme":[27,35,167],"during":[28,168],"operation":[30,169],"is":[31,36,50,94,99,146,176],"presented.":[32],"The":[33,61,135],"proposed":[34,117,166],"achieved":[37],"by":[38,52,164],"monitoring":[39],"second-order":[41],"harmonic":[42,63,80,140],"component":[43],"q-axis":[45],"current":[46,109],"fault":[49,93,104,118,143,159],"detected":[51,163],"comparing":[53],"these":[54],"components":[55],"with":[56,77],"those":[57],"normal":[59],"conditions.":[60],"non-fault":[62],"data":[64,81],"arbitrary":[67],"operating":[68,97],"condition":[69,175],"are":[70],"determined":[71],"using":[72,106,148],"linear":[74],"interpolation":[75],"method":[76],"several":[78],"sample":[79],"pre-measured":[82],"stage":[85],"of":[86,115],"initial":[88],"setup.":[90],"Once":[91],"detected,":[95],"mode":[98],"changed":[100],"to":[101,124],"identify":[102],"source":[105],"phase":[108],"waveform.":[110],"verify":[112],"effectiveness":[114],"detecting":[119,144],"scheme,":[120],"test":[122],"allow":[125],"inter-turn":[126],"short":[127],"has":[132],"been":[133],"built.":[134],"entire":[136],"control":[137],"system":[138],"including":[139],"analysis":[141],"algorithm":[145],"implemented":[147],"digital":[149],"signal":[150],"processor":[151],"TMS320F28335.":[152],"Without":[153],"requiring":[154],"additional":[156],"hardware,":[157],"can":[160],"be":[161],"effectively":[162],"so":[170],"long":[171],"as":[172],"steady-state":[174],"satisfied.":[177]},"cited_by_api_url":"https://api.openalex.org/works?filter=cites:W2167753191","counts_by_year":[{"year":2025,"cited_by_count":2},{"year":2024,"cited_by_count":2},{"year":2023,"cited_by_count":2},{"year":2022,"cited_by_count":3},{"year":2021,"cited_by_count":2},{"year":2020,"cited_by_count":3},{"year":2019,"cited_by_count":7},{"year":2018,"cited_by_count":5},{"year":2017,"cited_by_count":4},{"year":2016,"cited_by_count":2},{"year":2015,"cited_by_count":5},{"year":2014,"cited_by_count":3},{"year":2013,"cited_by_count":5},{"year":2012,"cited_by_count":4}],"updated_date":"2026-11-16T12:05:36.265796","created_date":"2016-06-24T00:00:00"}
