{"id":"https://openalex.org/W2167058705","doi":"https://doi.org/10.1111/j.1600-0668.1993.00003.x","title":"Non-Specific Symptoms In Office Workers: A Review And Summary Of The Epidemiologic Literature","display_name":"Non-Specific Symptoms In Office Workers: A Review And Summary Of The Epidemiologic Literature","publication_year":1993,"publication_date":"1993-12-01","ids":{"openalex":"https://openalex.org/W2167058705","doi":"https://doi.org/10.1111/j.1600-0668.1993.00003.x","mag":"2167058705"},"language":"en","primary_location":{"id":"doi:10.1111/j.1600-0668.1993.00003.x","doi":"https://doi.org/10.1111/j.1600-0668.1993.00003.x","is_oa":false,"landing_page_url":"https://doi.org/10.1111/j.1600-0668.1993.00003.x","pdf_url":null,"source":{"id":"https://openalex.org/S12992298","display_name":"Indoor Air","issn_l":"0905-6947","issn":["0905-6947","1600-0668"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["anvur-class-a","anvur-scientific","cwts-core","dongbi-b","jufo-2","ki-jl-1","norway-1","poland-140","russia-white-list-1","vabb-shw"],"host_organization":"https://openalex.org/P4310320595","host_organization_name":"Wiley","host_organization_lineage":["https://openalex.org/P4310320595"],"host_organization_lineage_names":["Wiley"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Indoor Air","raw_type":"journal-article"},"volume":null,"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5010451247","display_name":"Mark J. Mendell","orcid":"https://orcid.org/0000-0001-7194-7654","observed_orcids":["https://orcid.org/0000-0001-7194-7654"]},"institutions":[{"id":"https://openalex.org/I198423848","display_name":"National Institute for Occupational Safety and Health","ror":"https://ror.org/0502a2655","country_code":"US","type":"facility","lineage":["https://openalex.org/I1289490764","https://openalex.org/I1299022934","https://openalex.org/I198423848"]}],"countries":["US"],"is_corresponding":true,"raw_author_name":"Mark J. Mendell","raw_affiliation_strings":["National Institute for Occupational Safety and Health, Industrywide Studies Branch, 4676 Columbia Parkway, R-16, Cincinnati, OH 45266, USA"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"National Institute for Occupational Safety and Health, Industrywide Studies Branch, 4676 Columbia Parkway, R-16, Cincinnati, OH 45266, USA","institution_ids":["https://openalex.org/I198423848"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":["https://openalex.org/A5010451247"],"corresponding_institution_ids":["https://openalex.org/I198423848"],"apc_list":{"value":2490,"currency":"USD","value_usd":2490},"apc_paid":null,"fwci":8.4196,"has_fulltext":false,"cited_by_count":282,"citation_normalized_percentile":{"value":0.9863143,"is_in_top_1_percent":false,"is_in_top_10_percent":true},"cited_by_percentile_year":{"min":93,"max":99},"biblio":{"volume":"3","issue":"4","first_page":"227","last_page":"236"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11002","display_name":"Indoor Air Quality and Microbial Exposure","score":0.9502000212669373,"subfield":{"id":"https://openalex.org/subfields/2307","display_name":"Health, Toxicology and Mutagenesis"},"field":{"id":"https://openalex.org/fields/23","display_name":"Environmental Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11002","display_name":"Indoor Air Quality and Microbial Exposure","score":0.9502000212669373,"subfield":{"id":"https://openalex.org/subfields/2307","display_name":"Health, Toxicology and Mutagenesis"},"field":{"id":"https://openalex.org/fields/23","display_name":"Environmental Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12256","display_name":"Facilities and Workplace Management","score":0.029600000008940697,"subfield":{"id":"https://openalex.org/subfields/3207","display_name":"Social Psychology"},"field":{"id":"https://openalex.org/fields/32","display_name":"Psychology"},"domain":{"id":"https://openalex.org/domains/2","display_name":"Social Sciences"}},{"id":"https://openalex.org/T12208","display_name":"Occupational exposure and asthma","score":0.007499999832361937,"subfield":{"id":"https://openalex.org/subfields/2739","display_name":"Public Health, Environmental and Occupational Health"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/nonspecific-symptoms","display_name":"non-specific symptoms","score":0.9190000295639038},{"id":"https://openalex.org/keywords/office-workers","display_name":"office workers","score":0.9940000176429749},{"id":"https://openalex.org/keywords/work-related-symptoms","display_name":"work-related symptoms","score":0.6949999928474426},{"id":"https://openalex.org/keywords/indoor-air-quality","display_name":"indoor air quality","score":0.7360000014305115},{"id":"https://openalex.org/keywords/air-conditioning","display_name":"air conditioning","score":0.7289999723434448},{"id":"https://openalex.org/keywords/carpets","display_name":"carpets","score":0.593999981880188},{"id":"https://openalex.org/keywords/ventilation-rate","display_name":"ventilation rate","score":0.8600000143051147},{"id":"https://openalex.org/keywords/video-display-terminals","display_name":"visual display terminals","score":0.7379999756813049},{"id":"https://openalex.org/keywords/humidification","display_name":"humidification","score":0.7879999876022339},{"id":"https://openalex.org/keywords/negative-ionization","display_name":"negative ionization","score":0.9760000109672546},{"id":"https://openalex.org/keywords/office-cleaning","display_name":"office cleaning","score":0.8360000252723694},{"id":"https://openalex.org/keywords/temperature-and-relative-humidity","display_name":"temperature and relative humidity","score":0.7540000081062317},{"id":"https://openalex.org/keywords/occupational-stress","display_name":"occupational stress","score":0.9430000185966492},{"id":"https://openalex.org/keywords/gender-differences","display_name":"gender differences","score":0.7739999890327454},{"id":"https://openalex.org/keywords/allergy","display_name":"allergy","score":0.5569999814033508},{"id":"https://openalex.org/keywords/asthma","display_name":"asthma","score":0.8460000157356262},{"id":"https://openalex.org/keywords/occupational-health","display_name":"occupational health","score":0.4090000092983246}],"concepts":[{"id":"https://openalex.org/C114997826","wikidata":"https://www.wikidata.org/wiki/Q1072290","display_name":"Sick building syndrome","level":3,"score":0.643829345703125},{"id":"https://openalex.org/C71924100","wikidata":"https://www.wikidata.org/wiki/Q11190","display_name":"Medicine","level":0,"score":0.6048594117164612},{"id":"https://openalex.org/C99454951","wikidata":"https://www.wikidata.org/wiki/Q932068","display_name":"Environmental health","level":1,"score":0.5924158692359924},{"id":"https://openalex.org/C2776042228","wikidata":"https://www.wikidata.org/wiki/Q35869","display_name":"Asthma","level":2,"score":0.44039028882980347},{"id":"https://openalex.org/C107130276","wikidata":"https://www.wikidata.org/wiki/Q133805","display_name":"Epidemiology","level":2,"score":0.43187737464904785},{"id":"https://openalex.org/C149923435","wikidata":"https://www.wikidata.org/wiki/Q37732","display_name":"Demography","level":1,"score":0.34338217973709106},{"id":"https://openalex.org/C74909509","wikidata":"https://www.wikidata.org/wiki/Q10387","display_name":"Gerontology","level":1,"score":0.33215364813804626},{"id":"https://openalex.org/C65469","wikidata":"https://www.wikidata.org/wiki/Q905504","display_name":"Indoor air quality","level":2,"score":0.14434990286827087},{"id":"https://openalex.org/C142724271","wikidata":"https://www.wikidata.org/wiki/Q7208","display_name":"Pathology","level":1,"score":0.14059144258499146},{"id":"https://openalex.org/C126322002","wikidata":"https://www.wikidata.org/wiki/Q11180","display_name":"Internal medicine","level":1,"score":0.12043747305870056},{"id":"https://openalex.org/C18903297","wikidata":"https://www.wikidata.org/wiki/Q7150","display_name":"Ecology","level":1,"score":0.0},{"id":"https://openalex.org/C144024400","wikidata":"https://www.wikidata.org/wiki/Q21201","display_name":"Sociology","level":0,"score":0.0},{"id":"https://openalex.org/C86803240","wikidata":"https://www.wikidata.org/wiki/Q420","display_name":"Biology","level":0,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1111/j.1600-0668.1993.00003.x","doi":"https://doi.org/10.1111/j.1600-0668.1993.00003.x","is_oa":false,"landing_page_url":"https://doi.org/10.1111/j.1600-0668.1993.00003.x","pdf_url":null,"source":{"id":"https://openalex.org/S12992298","display_name":"Indoor Air","issn_l":"0905-6947","issn":["0905-6947","1600-0668"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["anvur-class-a","anvur-scientific","cwts-core","dongbi-b","jufo-2","ki-jl-1","norway-1","poland-140","russia-white-list-1","vabb-shw"],"host_organization":"https://openalex.org/P4310320595","host_organization_name":"Wiley","host_organization_lineage":["https://openalex.org/P4310320595"],"host_organization_lineage_names":["Wiley"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Indoor Air","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[{"score":0.9537000060081482,"display_name":"Good health and well-being","id":"https://metadata.un.org/sdg/3"}],"study_designs":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":31,"referenced_works":["https://openalex.org/W1491087240","https://openalex.org/W1977069556","https://openalex.org/W1979296194","https://openalex.org/W1985967967","https://openalex.org/W1986412715","https://openalex.org/W1988589551","https://openalex.org/W1989520531","https://openalex.org/W1990433241","https://openalex.org/W1992268207","https://openalex.org/W2008126816","https://openalex.org/W2029495550","https://openalex.org/W2030999457","https://openalex.org/W2054306650","https://openalex.org/W2059263453","https://openalex.org/W2069524036","https://openalex.org/W2071574213","https://openalex.org/W2072119276","https://openalex.org/W2085346504","https://openalex.org/W2092344233","https://openalex.org/W2096923694","https://openalex.org/W2104108812","https://openalex.org/W2132054230","https://openalex.org/W2151524945","https://openalex.org/W2313546833","https://openalex.org/W2316094838","https://openalex.org/W2332245811","https://openalex.org/W4214659012","https://openalex.org/W4245551537","https://openalex.org/W4254945848","https://openalex.org/W4298282109","https://openalex.org/W4300224670"],"related_works":["https://openalex.org/W2313546833","https://openalex.org/W2910629123","https://openalex.org/W2151404902","https://openalex.org/W2783635739","https://openalex.org/W2048715077","https://openalex.org/W2132054230","https://openalex.org/W2116339181","https://openalex.org/W1507746702","https://openalex.org/W7032897773","https://openalex.org/W1992712428"],"abstract_inverted_index":{"Epidemiologic":[0],"research":[1,208],"into":[2],"the":[3,31,39],"causes":[4],"of":[5,15,33,41,44,110,195,202,222],"non-specific":[6],"symptoms":[7,64,90,147,185,197],"among":[8,186],"office":[9,50,102,187],"workers":[10,69,188],"has":[11],"produced":[12],"a":[13,71],"variety":[14],"conflicting":[16],"findings":[17,40,61,111,144,162,175],"which":[18],"are":[19],"difficult":[20],"to":[21,49],"synthesize.":[22],"This":[23],"paper":[24],"first":[25],"discusses":[26],"methodologic":[27],"issues":[28],"important":[29],"in":[30,70],"interpretation":[32],"epidemiologic":[34],"studies,":[35,218],"and":[36,75,100,114,122,153,171,192,216,226],"then":[37],"reviews":[38],"32":[42],"studies":[43,105,118,132],"37":[45],"factors":[46,55,138,160],"potentially":[47],"related":[48,184],"worker":[51],"symptoms.":[52],"Among":[53,136],"environmental":[54,157,203,224],"assessed,":[56,139,161],"there":[57,140,172],"were":[58,133,141,163,173,189],"generally":[59,142],"consistent":[60,143],"associating":[62,145],"increased":[63,127,146],"with":[65,84,92,126,148],"air-conditioning,":[66],"carpets,":[67],"more":[68],"space,":[72],"VDT":[73],"use,":[74],"ventilation":[76,94],"rates":[77],"at":[78],"or":[79,158,166,205],"below":[80],"10":[81],"liters/second/person.":[82],"Studies":[83],"particularly":[85],"strong":[86,117,131,177],"designs":[87],"found":[88],"decreased":[89],"associated":[91,119],"low":[93,123],"rate,":[95],"short-term":[96],"humidification,":[97],"negative":[98],"ionization,":[99],"improved":[101,220],"cleaning,":[103],"although":[104],"reviewed":[106],"showed":[107],"little":[108],"consistency":[109],"for":[112,168],"humidification":[113],"ionization.":[115],"Relatively":[116],"high":[120],"temperature":[121],"relative":[124],"humidity":[125],"symptoms,":[128],"whereas":[129],"less":[130],"not":[134],"consistent.":[135],"personal":[137,159],"female":[149],"gender,":[150],"job":[151],"stress/dissatisfaction,":[152],"allergies/asthma.":[154],"For":[155],"other":[156],"too":[164],"inconsistent":[165],"sparse":[167],"current":[169],"interpretation,":[170],"no":[174],"from":[176],"studies.":[178],"Overall":[179],"evidence":[180],"suggested":[181],"that":[182,193],"work":[183],"relatively":[190],"common,":[191],"some":[194],"these":[196],"represented":[198],"preventable":[199],"physiologic":[200],"effects":[201],"exposures":[204,225],"conditions.":[206],"Future":[207],"on":[209],"this":[210],"problem":[211],"should":[212],"include":[213],"blind":[214],"experimental":[215],"case-control":[217],"using":[219],"measurements":[221],"both":[223],"health":[227],"outcomes":[228]},"counts_by_year":[{"year":2026,"cited_by_count":5},{"year":2025,"cited_by_count":3},{"year":2024,"cited_by_count":2},{"year":2023,"cited_by_count":4},{"year":2022,"cited_by_count":5},{"year":2021,"cited_by_count":9},{"year":2020,"cited_by_count":5},{"year":2019,"cited_by_count":4},{"year":2018,"cited_by_count":8},{"year":2017,"cited_by_count":6},{"year":2016,"cited_by_count":8},{"year":2015,"cited_by_count":8},{"year":2014,"cited_by_count":6},{"year":2013,"cited_by_count":10},{"year":2012,"cited_by_count":7}],"updated_date":"2026-11-04T10:54:05.112534","created_date":"2016-06-24T00:00:00"}
