{"id":"https://openalex.org/W2166754652","doi":null,"title":"PocketECG: a new continuous and real-time ambulatory arrhythmia diagnostic method.","display_name":"PocketECG: a new continuous and real-time ambulatory arrhythmia diagnostic method.","publication_year":2011,"publication_date":"2011-01-01","ids":{"openalex":"https://openalex.org/W2166754652","mag":"2166754652","pmid":"https://pubmed.ncbi.nlm.nih.gov/21769831"},"language":"en","primary_location":{"id":"pmid:21769831","doi":null,"is_oa":false,"landing_page_url":"https://pubmed.ncbi.nlm.nih.gov/21769831","pdf_url":null,"source":{"id":"https://openalex.org/S4306525036","display_name":"PubMed","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I1299303238","host_organization_name":"National Institutes of Health","host_organization_lineage":["https://openalex.org/I1299303238"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Cardiology journal","raw_type":"Journal Article"},"volume":null,"type":"article","is_traditional":true,"indexed_in":["pubmed"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5048206824","display_name":"Marek Jacek Dziubinski","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":true,"raw_author_name":"Marek Dziubi\u0144ski","raw_affiliation_strings":["Medicalgorithmics S.A., ul. \u017burawia 22,Warsaw, Poland. m.dziubinski@medicalgorithmics.com"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Medicalgorithmics S.A., ul. \u017burawia 22,Warsaw, Poland. m.dziubinski@medicalgorithmics.com","institution_ids":[]}]}],"institutions":[],"countries_distinct_count":0,"institutions_distinct_count":0,"corresponding_author_ids":["https://openalex.org/A5048206824"],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.6439,"has_fulltext":false,"cited_by_count":10,"citation_normalized_percentile":{"value":0.72921106,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":88,"max":96},"biblio":{"volume":"18","issue":"4","first_page":"454","last_page":"60"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11021","display_name":"ECG Monitoring and Analysis","score":0.9735999703407288,"subfield":{"id":"https://openalex.org/subfields/2705","display_name":"Cardiology and Cardiovascular Medicine"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},"topics":[{"id":"https://openalex.org/T11021","display_name":"ECG Monitoring and Analysis","score":0.9735999703407288,"subfield":{"id":"https://openalex.org/subfields/2705","display_name":"Cardiology and Cardiovascular Medicine"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},{"id":"https://openalex.org/T11196","display_name":"Non-Invasive Vital Sign Monitoring","score":0.024900000542402267,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11932","display_name":"Wireless Body Area Networks","score":0.0003000000142492354,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/arrhythmia-diagnosis","display_name":"arrhythmia diagnosis","score":0.656000018119812},{"id":"https://openalex.org/keywords/holter-monitoring","display_name":"Holter monitoring","score":0.6930000185966492},{"id":"https://openalex.org/keywords/event-monitoring","display_name":"event monitoring","score":0.8109999895095825},{"id":"https://openalex.org/keywords/symptom-reporting","display_name":"symptom reporting","score":0.8220000267028809},{"id":"https://openalex.org/keywords/wearable-ecg","display_name":"wearable ECG","score":0.6610000133514404}],"concepts":[{"id":"https://openalex.org/C71924100","wikidata":"https://www.wikidata.org/wiki/Q11190","display_name":"Medicine","level":0,"score":0.772921085357666},{"id":"https://openalex.org/C2909021529","wikidata":"https://www.wikidata.org/wiki/Q11490631","display_name":"Ambulatory ECG","level":3,"score":0.7469497323036194},{"id":"https://openalex.org/C35785553","wikidata":"https://www.wikidata.org/wiki/Q756720","display_name":"Ambulatory","level":2,"score":0.721964955329895},{"id":"https://openalex.org/C183121708","wikidata":"https://www.wikidata.org/wiki/Q209867","display_name":"Telemetry","level":2,"score":0.6379013657569885},{"id":"https://openalex.org/C164705383","wikidata":"https://www.wikidata.org/wiki/Q10379","display_name":"Cardiology","level":1,"score":0.4732789695262909},{"id":"https://openalex.org/C2988455589","wikidata":"https://www.wikidata.org/wiki/Q189331","display_name":"Cardiac arrhythmia","level":3,"score":0.4708865284919739},{"id":"https://openalex.org/C2776902269","wikidata":"https://www.wikidata.org/wiki/Q5165493","display_name":"Continuous monitoring","level":2,"score":0.46123242378234863},{"id":"https://openalex.org/C126322002","wikidata":"https://www.wikidata.org/wiki/Q11180","display_name":"Internal medicine","level":1,"score":0.4521510601043701},{"id":"https://openalex.org/C79403827","wikidata":"https://www.wikidata.org/wiki/Q3988","display_name":"Real-time computing","level":1,"score":0.36068564653396606},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.20646044611930847},{"id":"https://openalex.org/C2779161974","wikidata":"https://www.wikidata.org/wiki/Q815819","display_name":"Atrial fibrillation","level":2,"score":0.1503971815109253},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.10084903240203857},{"id":"https://openalex.org/C76155785","wikidata":"https://www.wikidata.org/wiki/Q418","display_name":"Telecommunications","level":1,"score":0.0978909432888031},{"id":"https://openalex.org/C21547014","wikidata":"https://www.wikidata.org/wiki/Q1423657","display_name":"Operations management","level":1,"score":0.0}],"mesh":[{"descriptor_ui":"D001145","descriptor_name":"Arrhythmias, Cardiac","qualifier_ui":"Q000175","qualifier_name":"diagnosis","is_major_topic":true},{"descriptor_ui":"D001145","descriptor_name":"Arrhythmias, Cardiac","qualifier_ui":"Q000503","qualifier_name":"physiopathology","is_major_topic":false},{"descriptor_ui":"D003199","descriptor_name":"Computer Systems","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D004867","descriptor_name":"Equipment Design","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D006801","descriptor_name":"Humans","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D011237","descriptor_name":"Predictive Value of Tests","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D012815","descriptor_name":"Signal Processing, Computer-Assisted","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D013686","descriptor_name":"Telemetry","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":true},{"descriptor_ui":"D015716","descriptor_name":"Electrocardiography, Ambulatory","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":true}],"locations_count":1,"locations":[{"id":"pmid:21769831","doi":null,"is_oa":false,"landing_page_url":"https://pubmed.ncbi.nlm.nih.gov/21769831","pdf_url":null,"source":{"id":"https://openalex.org/S4306525036","display_name":"PubMed","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I1299303238","host_organization_name":"National Institutes of Health","host_organization_lineage":["https://openalex.org/I1299303238"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Cardiology journal","raw_type":"Journal Article"}],"best_oa_location":null,"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/3","display_name":"Good health and well-being","score":0.8048999905586243}],"study_designs":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":16,"referenced_works":["https://openalex.org/W1482688465","https://openalex.org/W2008587878","https://openalex.org/W2012123493","https://openalex.org/W2019768128","https://openalex.org/W2021668255","https://openalex.org/W2025157621","https://openalex.org/W2055008517","https://openalex.org/W2066069714","https://openalex.org/W2066071317","https://openalex.org/W2078908559","https://openalex.org/W2082353817","https://openalex.org/W2109107913","https://openalex.org/W2134120396","https://openalex.org/W2136493572","https://openalex.org/W2137639918","https://openalex.org/W2613326162"],"related_works":["https://openalex.org/W2394633966","https://openalex.org/W2418808189","https://openalex.org/W6979013188","https://openalex.org/W2398131318","https://openalex.org/W4379378072","https://openalex.org/W1514868647","https://openalex.org/W2088833861","https://openalex.org/W3204901122","https://openalex.org/W2956370390","https://openalex.org/W2407973435"],"abstract_inverted_index":{"This":[0,29],"article":[1],"presents":[2],"a":[3,16,43,67,80],"new":[4,30],"approach":[5],"to":[6],"ambulatory":[7],"arrhythmia":[8,90],"monitoring,":[9],"one":[10],"which":[11,83],"can":[12],"be":[13,85],"viewed":[14],"as":[15,87],"natural":[17],"evolution":[18],"of":[19,36,46,53,58,71],"the":[20,33,54,88],"existing":[21],"non-invasive":[22],"methods":[23],"for":[24],"diagnosing":[25],"heart":[26],"rhythm":[27],"abnormalities.":[28],"method":[31],"combines":[32,64],"real-time":[34],"capabilities":[35],"modern":[37],"mobile":[38],"cardiovascular":[39],"telemetry":[40],"systems":[41],"with":[42,66],"quantitative":[44],"way":[45],"reporting":[47],"measured":[48],"findings":[49],"and":[50],"continuous":[51],"storage":[52],"ECG":[55],"data":[56],"typical":[57,70],"Holter":[59],"monitoring":[60,73],"systems.":[61],"It":[62],"further":[63],"this":[65],"symptom-reporting":[68],"capability":[69],"event":[72],"applications.":[74],"Combining":[75],"all":[76],"these":[77],"features":[78],"produces":[79],"single":[81],"device":[82],"could":[84],"described":[86],"ultimate":[89],"diagnostic":[91],"tool.":[92]},"counts_by_year":[{"year":2023,"cited_by_count":1},{"year":2022,"cited_by_count":1},{"year":2020,"cited_by_count":1},{"year":2017,"cited_by_count":2},{"year":2016,"cited_by_count":2},{"year":2013,"cited_by_count":2},{"year":2012,"cited_by_count":1}],"updated_date":"2026-10-31T12:09:11.096373","created_date":"2016-06-24T00:00:00"}
