{"id":"https://openalex.org/W2166473271","doi":"https://doi.org/10.1177/0954409714528485","title":"Reliability and measurement accuracy of a condition monitoring system in an extreme climate: A case study of automatic laser scanning of wheel profiles","display_name":"Reliability and measurement accuracy of a condition monitoring system in an extreme climate: A case study of automatic laser scanning of wheel profiles","publication_year":2014,"publication_date":"2014-04-21","ids":{"openalex":"https://openalex.org/W2166473271","doi":"https://doi.org/10.1177/0954409714528485","mag":"2166473271"},"language":"en","primary_location":{"id":"doi:10.1177/0954409714528485","doi":"https://doi.org/10.1177/0954409714528485","is_oa":false,"landing_page_url":"https://doi.org/10.1177/0954409714528485","pdf_url":null,"source":{"id":"https://openalex.org/S97582030","display_name":"Proceedings of the Institution of Mechanical Engineers Part F Journal of Rail and Rapid Transit","issn_l":"0954-4097","issn":["0954-4097","2041-3017"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["cwts-core","dongbi-b","jufo-1","ki-jl-1","norway-1","poland-70","russia-white-list-1"],"host_organization":"https://openalex.org/P4310320017","host_organization_name":"SAGE Publishing","host_organization_lineage":["https://openalex.org/P4310320017"],"host_organization_lineage_names":["SAGE Publishing"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Proceedings of the Institution of Mechanical Engineers, Part F: Journal of Rail and Rapid Transit","raw_type":"journal-article"},"volume":null,"type":"article","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5101932821","display_name":"Matthias Asplund","orcid":"https://orcid.org/0000-0003-1782-2484","observed_orcids":["https://orcid.org/0000-0003-1782-2484"]},"institutions":[{"id":"https://openalex.org/I146360087","display_name":"Swedish Transport Administration","ror":"https://ror.org/000nes056","country_code":"SE","type":"government","lineage":["https://openalex.org/I146360087"]},{"id":"https://openalex.org/I190632392","display_name":"Lule\u00e5 University of Technology","ror":"https://ror.org/016st3p78","country_code":"SE","type":"education","lineage":["https://openalex.org/I190632392"]}],"countries":["SE"],"is_corresponding":true,"raw_author_name":"Matthias Asplund","raw_affiliation_strings":["Division of Operation, Maintenance and Acoustics, Lule\u00e5 University of Technology, Sweden","Trafikverket, Sweden"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Division of Operation, Maintenance and Acoustics, Lule\u00e5 University of Technology, Sweden","institution_ids":["https://openalex.org/I190632392"]},{"raw_affiliation_string":"Trafikverket, Sweden","institution_ids":["https://openalex.org/I146360087"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5018662273","display_name":"Per Gustafsson","orcid":"https://orcid.org/0009-0006-0682-5056","observed_orcids":["https://orcid.org/0009-0006-0682-5056"]},"institutions":[{"id":"https://openalex.org/I4210100060","display_name":"Sweco (Sweden)","ror":"https://ror.org/010ees266","country_code":"SE","type":"company","lineage":["https://openalex.org/I4210100060"]}],"countries":["SE"],"is_corresponding":false,"raw_author_name":"Per Gustafsson","raw_affiliation_strings":["SWECO Energuide AB, Sweden"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"SWECO Energuide AB, Sweden","institution_ids":["https://openalex.org/I4210100060"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5048627198","display_name":"Thomas Nordmark","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I4210089113","display_name":"Luossavaara-Kiirunavaara Aktiebolag (Sweden)","ror":"https://ror.org/00962x353","country_code":"SE","type":"company","lineage":["https://openalex.org/I4210089113"]}],"countries":["SE"],"is_corresponding":false,"raw_author_name":"Thomas Nordmark","raw_affiliation_strings":["LKAB, Sweden"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"LKAB, Sweden","institution_ids":["https://openalex.org/I4210089113"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5029668557","display_name":"Matti Rantatalo","orcid":"https://orcid.org/0000-0002-8471-4494","observed_orcids":["https://orcid.org/0000-0002-8471-4494"]},"institutions":[{"id":"https://openalex.org/I190632392","display_name":"Lule\u00e5 University of Technology","ror":"https://ror.org/016st3p78","country_code":"SE","type":"education","lineage":["https://openalex.org/I190632392"]}],"countries":["SE"],"is_corresponding":false,"raw_author_name":"Matti Rantatalo","raw_affiliation_strings":["Division of Operation, Maintenance and Acoustics, Lule\u00e5 University of Technology, Sweden"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Division of Operation, Maintenance and Acoustics, Lule\u00e5 University of Technology, Sweden","institution_ids":["https://openalex.org/I190632392"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5083797539","display_name":"Mikael Palo","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I190632392","display_name":"Lule\u00e5 University of Technology","ror":"https://ror.org/016st3p78","country_code":"SE","type":"education","lineage":["https://openalex.org/I190632392"]}],"countries":["SE"],"is_corresponding":false,"raw_author_name":"Mikael Palo","raw_affiliation_strings":["Division of Operation, Maintenance and Acoustics, Lule\u00e5 University of Technology, Sweden"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Division of Operation, Maintenance and Acoustics, Lule\u00e5 University of Technology, Sweden","institution_ids":["https://openalex.org/I190632392"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5034025020","display_name":"Stephen Mayowa Famurewa","orcid":"https://orcid.org/0000-0001-9843-5819","observed_orcids":["https://orcid.org/0000-0001-9843-5819"]},"institutions":[{"id":"https://openalex.org/I190632392","display_name":"Lule\u00e5 University of Technology","ror":"https://ror.org/016st3p78","country_code":"SE","type":"education","lineage":["https://openalex.org/I190632392"]}],"countries":["SE"],"is_corresponding":false,"raw_author_name":"Stephen Mayowa Famurewa","raw_affiliation_strings":["Division of Operation, Maintenance and Acoustics, Lule\u00e5 University of Technology, Sweden"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Division of Operation, Maintenance and Acoustics, Lule\u00e5 University of Technology, Sweden","institution_ids":["https://openalex.org/I190632392"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5054059482","display_name":"Karina Wandt","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I190632392","display_name":"Lule\u00e5 University of Technology","ror":"https://ror.org/016st3p78","country_code":"SE","type":"education","lineage":["https://openalex.org/I190632392"]}],"countries":["SE"],"is_corresponding":false,"raw_author_name":"Karina Wandt","raw_affiliation_strings":["Division of Operation, Maintenance and Acoustics, Lule\u00e5 University of Technology, Sweden"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Division of Operation, Maintenance and Acoustics, Lule\u00e5 University of Technology, Sweden","institution_ids":["https://openalex.org/I190632392"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":4,"corresponding_author_ids":["https://openalex.org/A5101932821"],"corresponding_institution_ids":["https://openalex.org/I146360087","https://openalex.org/I190632392"],"apc_list":{"value":4150,"currency":"USD","value_usd":4150},"apc_paid":null,"fwci":4.938,"has_fulltext":false,"cited_by_count":19,"citation_normalized_percentile":{"value":0.93453779,"is_in_top_1_percent":false,"is_in_top_10_percent":true},"cited_by_percentile_year":{"min":87,"max":97},"biblio":{"volume":"228","issue":"6","first_page":"695","last_page":"704"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10780","display_name":"Reliability and Maintenance Optimization","score":0.453900009393692,"subfield":{"id":"https://openalex.org/subfields/2213","display_name":"Safety, Risk, Reliability and Quality"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10780","display_name":"Reliability and Maintenance Optimization","score":0.453900009393692,"subfield":{"id":"https://openalex.org/subfields/2213","display_name":"Safety, Risk, Reliability and Quality"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10842","display_name":"Railway Engineering and Dynamics","score":0.27079999446868896,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T13615","display_name":"Transportation Systems and Safety","score":0.2224999964237213,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/laser-scanning","display_name":"laser scanning","score":0.6240000128746033},{"id":"https://openalex.org/keywords/railway-condition-monitoring","display_name":"railway condition monitoring","score":0.7620000243186951},{"id":"https://openalex.org/keywords/extreme-climate-events","display_name":"climate extremes","score":0.45100000500679016},{"id":"https://openalex.org/keywords/reliability","display_name":"reliability","score":0.5199999809265137},{"id":"https://openalex.org/keywords/measurement-accuracy","display_name":"measurement accuracy","score":0.9210000038146973},{"id":"https://openalex.org/keywords/rams","display_name":"rams","score":0.5540000200271606},{"id":"https://openalex.org/keywords/system-life-cycle","display_name":"system life cycle","score":0.7089999914169312},{"id":"https://openalex.org/keywords/v-model","display_name":"V-model","score":0.8199999928474426},{"id":"https://openalex.org/keywords/railway-maintenance","display_name":"railway maintenance","score":0.3199999928474426},{"id":"https://openalex.org/keywords/cold-weather-operation","display_name":"cold weather operation","score":0.36500000953674316}],"concepts":[{"id":"https://openalex.org/C89992363","wikidata":"https://www.wikidata.org/wiki/Q5961558","display_name":"Track (disk drive)","level":2,"score":0.7233458757400513},{"id":"https://openalex.org/C160713754","wikidata":"https://www.wikidata.org/wiki/Q1389965","display_name":"Maintainability","level":2,"score":0.7114542126655579},{"id":"https://openalex.org/C190839683","wikidata":"https://www.wikidata.org/wiki/Q2448197","display_name":"Train","level":2,"score":0.690102219581604},{"id":"https://openalex.org/C129727815","wikidata":"https://www.wikidata.org/wiki/Q188209","display_name":"Axle","level":2,"score":0.6320761442184448},{"id":"https://openalex.org/C43214815","wikidata":"https://www.wikidata.org/wiki/Q7310987","display_name":"Reliability (semiconductor)","level":3,"score":0.5966665744781494},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.5335702300071716},{"id":"https://openalex.org/C32802771","wikidata":"https://www.wikidata.org/wiki/Q2443617","display_name":"Port (circuit theory)","level":2,"score":0.45832717418670654},{"id":"https://openalex.org/C198352243","wikidata":"https://www.wikidata.org/wiki/Q37105","display_name":"Line (geometry)","level":2,"score":0.41289883852005005},{"id":"https://openalex.org/C22212356","wikidata":"https://www.wikidata.org/wiki/Q775325","display_name":"Transport engineering","level":1,"score":0.407069593667984},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.28032925724983215},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.19454079866409302},{"id":"https://openalex.org/C205649164","wikidata":"https://www.wikidata.org/wiki/Q1071","display_name":"Geography","level":0,"score":0.0},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.0},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C2524010","wikidata":"https://www.wikidata.org/wiki/Q8087","display_name":"Geometry","level":1,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C58640448","wikidata":"https://www.wikidata.org/wiki/Q42515","display_name":"Cartography","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1177/0954409714528485","doi":"https://doi.org/10.1177/0954409714528485","is_oa":false,"landing_page_url":"https://doi.org/10.1177/0954409714528485","pdf_url":null,"source":{"id":"https://openalex.org/S97582030","display_name":"Proceedings of the Institution of Mechanical Engineers Part F Journal of Rail and Rapid Transit","issn_l":"0954-4097","issn":["0954-4097","2041-3017"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["cwts-core","dongbi-b","jufo-1","ki-jl-1","norway-1","poland-70","russia-white-list-1"],"host_organization":"https://openalex.org/P4310320017","host_organization_name":"SAGE Publishing","host_organization_lineage":["https://openalex.org/P4310320017"],"host_organization_lineage_names":["SAGE Publishing"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Proceedings of the Institution of Mechanical Engineers, Part F: Journal of Rail and Rapid Transit","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[{"display_name":"Industry, innovation and infrastructure","score":1.0,"id":"https://metadata.un.org/sdg/9"}],"study_designs":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":11,"referenced_works":["https://openalex.org/W574754340","https://openalex.org/W2014908996","https://openalex.org/W2056918715","https://openalex.org/W2132433083","https://openalex.org/W2141386066","https://openalex.org/W2151328500","https://openalex.org/W2237711947","https://openalex.org/W2465088004","https://openalex.org/W2542804400","https://openalex.org/W2617230775","https://openalex.org/W2801175407"],"related_works":["https://openalex.org/W7096667430","https://openalex.org/W2980428244","https://openalex.org/W2248521073","https://openalex.org/W2807153332","https://openalex.org/W2131400590","https://openalex.org/W2617230775","https://openalex.org/W2133036464","https://openalex.org/W810297366","https://openalex.org/W2711537620","https://openalex.org/W3149257556"],"abstract_inverted_index":{"The":[0,63,118,179,200,260],"Iron":[1],"Ore":[2],"Line":[3],"(Malmbanan)":[4],"is":[5,49,57,124,166,186,245,277,300],"a":[6,98,115,161,190,220,240],"473":[7],"km":[8],"long":[9],"track":[10,24,40,106],"section":[11,25],"located":[12],"in":[13,19,131,189,265],"northern":[14],"Sweden":[15,31],"and":[16,32,34,53,68,74,93,103,107,112,134,173,183,185,197,211,225,230,234,256,272,284,292],"has":[17,154],"been":[18,155],"operation":[20],"since":[21],"1903.":[22],"This":[23,217],"stretches":[26],"through":[27],"two":[28],"countries,":[29],"namely":[30],"Norway,":[33],"the":[35,39,43,47,50,54,71,80,88,94,105,121,127,136,169,194,206,209,223,228,231,237,253,280,288,297],"main":[36],"part":[37],"of":[38,87,101,120,126,208,222,227,236,275,287],"runs":[41],"on":[42,114,157,168,247],"Swedish":[44,51,60],"side,":[45],"where":[46],"owner":[48],"Government":[52],"infrastructure":[55,198],"manager":[56],"Trafikverket":[58],"(the":[59],"Transport":[61],"Administration).":[62],"ore":[64,102],"trains":[65],"are":[66,202,258,290],"owned":[67],"managed":[69],"by":[70,85],"freight":[72,195],"operator":[73,196],"mining":[75],"company":[76],"LKAB.":[77],"Due":[78],"to":[79,204,212],"high":[81,95],"axle":[82],"load":[83],"exerted":[84],"transportation":[86],"iron":[89],"ore,":[90],"30":[91],"tonnes,":[92],"demand":[96],"for":[97,177,249,296],"constant":[99],"flow":[100],"pellets,":[104],"wagons":[108],"must":[109],"be":[110],"monitored":[111],"maintained":[113],"regular":[116],"basis.":[117],"condition":[119,207],"wagon":[122],"wheel":[123,137,149],"one":[125],"most":[128],"important":[129,141],"aspects":[130],"this":[132,144,158],"connection,":[133],"here":[135],"profile":[138,150,254],"plays":[139],"an":[140,146,293],"role.":[142],"For":[143],"reason":[145],"automatic":[147],"laser-based":[148],"monitoring":[151],"system":[152,162,180,241,289],"(WPMS)":[153],"installed":[156,184],"line":[159],"using":[160,239],"lifecycle":[163,242,298],"approach":[164,176,243,299],"that":[165,244],"based":[167,246],"reliability,":[170],"availability,":[171],"maintainability":[172],"safety":[174],"(RAMS)":[175],"railways.":[178,250],"was":[181],"prepared":[182],"being":[187],"operated":[188],"collaborative":[191],"project":[192],"between":[193],"manager.":[199],"measurements":[201,255],"used":[203],"diagnose":[205],"wheels,":[210],"further":[213],"optimize":[214],"their":[215],"maintenance.":[216],"paper":[218],"presents":[219],"study":[221],"concepts":[224],"ideas":[226],"WPMS,":[229],"selection,":[232],"installation":[233],"validation":[235,257],"equipment":[238],"RAMS":[248],"Results":[251],"from":[252],"shown.":[259],"system\u2019s":[261],"reliability":[262],"during":[263],"performance":[264],"extreme":[266],"climate":[267],"conditions,":[268],"with":[269],"severe":[270],"cold":[271],"large":[273],"quantities":[274],"snow,":[276],"presented.":[278,301],"Then":[279],"benefits,":[281],"perceived":[282],"challenges":[283],"acquired":[285],"knowledge":[286],"discussed,":[291],"improved":[294],"V-model":[295]},"counts_by_year":[{"year":2026,"cited_by_count":2},{"year":2025,"cited_by_count":3},{"year":2024,"cited_by_count":2},{"year":2022,"cited_by_count":1},{"year":2021,"cited_by_count":1},{"year":2020,"cited_by_count":2},{"year":2019,"cited_by_count":1},{"year":2017,"cited_by_count":3},{"year":2016,"cited_by_count":2},{"year":2015,"cited_by_count":2}],"updated_date":"2026-11-07T11:25:07.637180","created_date":"2016-06-24T00:00:00"}
