{"id":"https://openalex.org/W2162281450","doi":"https://doi.org/10.1109/63.849029","title":"A bidirectional DC-DC converter topology for low power application","display_name":"A bidirectional DC-DC converter topology for low power application","alternate_titles":[],"publication_year":2000,"publication_date":"2000-07-01","ids":{"openalex":"https://openalex.org/W2162281450","doi":"https://doi.org/10.1109/63.849029","mag":"2162281450"},"language":"en","primary_location":{"id":"doi:10.1109/63.849029","doi":"https://doi.org/10.1109/63.849029","is_oa":false,"landing_page_url":"https://doi.org/10.1109/63.849029","pdf_url":null,"source":{"id":"https://openalex.org/S29875816","display_name":"IEEE Transactions on Power Electronics","issn_l":"0885-8993","issn":["0885-8993","1941-0107"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["cwts-core","dongbi-a","jufo-3","norway-2","poland-200","russia-white-list-1"],"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Power Electronics","raw_type":"journal-article"},"parent_works":[],"lineage":["https://openalex.org/W2162281450"],"child_works_count":0,"type":"article","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":null,"display_name":"M. Jain","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I60158472","display_name":"Concordia University","ror":"https://ror.org/0420zvk78","country_code":"CA","type":"education","lineage":["https://openalex.org/I60158472"]}],"countries":["CA"],"is_corresponding":false,"raw_author_name":"M. Jain","raw_affiliation_strings":["P. D. Ziogas Power Electronics Laboratory, Department of Electrical and Computer Engineering, Concordia University, Montreal, QUE, Canada","Dept., of Electr. & Comput. Eng., Concordia Univ., Montreal, Que., Canada"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"P. D. Ziogas Power Electronics Laboratory, Department of Electrical and Computer Engineering, Concordia University, Montreal, QUE, Canada","institution_ids":["https://openalex.org/I60158472"]},{"raw_affiliation_string":"Dept., of Electr. & Comput. Eng., Concordia Univ., Montreal, Que., Canada","institution_ids":["https://openalex.org/I60158472"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5088849457","display_name":"M. Daniele","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I60158472","display_name":"Concordia University","ror":"https://ror.org/0420zvk78","country_code":"CA","type":"education","lineage":["https://openalex.org/I60158472"]}],"countries":["CA"],"is_corresponding":false,"raw_author_name":"M. Daniele","raw_affiliation_strings":["P. D. Ziogas Power Electronics Laboratory, Department of Electrical and Computer Engineering, Concordia University, Montreal, QUE, Canada","[P. D. Ziogas Power Electronics Laboratory Department of Electrical & Computer Engineering, Concordia University, Montreal, QUE, Canada]"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"P. D. Ziogas Power Electronics Laboratory, Department of Electrical and Computer Engineering, Concordia University, Montreal, QUE, Canada","institution_ids":["https://openalex.org/I60158472"]},{"raw_affiliation_string":"[P. D. Ziogas Power Electronics Laboratory Department of Electrical & Computer Engineering, Concordia University, Montreal, QUE, Canada]","institution_ids":["https://openalex.org/I60158472"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5101981743","display_name":"Praveen Kumar Jain","orcid":"https://orcid.org/0000-0003-2528-8349","observed_orcids":["https://orcid.org/0000-0003-2528-8349"]},"institutions":[{"id":"https://openalex.org/I60158472","display_name":"Concordia University","ror":"https://ror.org/0420zvk78","country_code":"CA","type":"education","lineage":["https://openalex.org/I60158472"]}],"countries":["CA"],"is_corresponding":false,"raw_author_name":"P.K. Jain","raw_affiliation_strings":["P. D. Ziogas Power Electronics Laboratory, Department of Electrical and Computer Engineering, Concordia University, Montreal, QUE, Canada","[P. D. Ziogas Power Electronics Laboratory Department of Electrical & Computer Engineering, Concordia University, Montreal, QUE, Canada]"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"P. D. Ziogas Power Electronics Laboratory, Department of Electrical and Computer Engineering, Concordia University, Montreal, QUE, Canada","institution_ids":["https://openalex.org/I60158472"]},{"raw_affiliation_string":"[P. D. Ziogas Power Electronics Laboratory Department of Electrical & Computer Engineering, Concordia University, Montreal, QUE, Canada]","institution_ids":["https://openalex.org/I60158472"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":["https://openalex.org/I60158472"],"apc_list":{"value":2645,"currency":"USD","value_usd":2645},"apc_paid":null,"fwci":3.0431,"has_fulltext":false,"cited_by_count":281,"citation_normalized_percentile":{"value":0.90212828,"is_in_top_1_percent":false,"is_in_top_10_percent":true},"cited_by_percentile_year":{"min":97,"max":100},"biblio":{"volume":"15","issue":"4","first_page":"595","last_page":"606"},"is_retracted":false,"is_pulled":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10175","display_name":"Advanced DC-DC Converters","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10175","display_name":"Advanced DC-DC Converters","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11249","display_name":"Wireless Power Transfer Systems","score":0.0,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10228","display_name":"Multilevel Inverters and Converters","score":0.0,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/bidirectional-dc-dc-converter","display_name":"bidirectional DC-DC converter","score":1.0},{"id":"https://openalex.org/keywords/half-bridge-converter","display_name":"half-bridge converter","score":0.8230000138282776},{"id":"https://openalex.org/keywords/isolation-transformer","display_name":"isolation transformer","score":0.8650000095367432},{"id":"https://openalex.org/keywords/battery-charging","display_name":"battery charging","score":0.5630000233650208},{"id":"https://openalex.org/keywords/battery-discharge","display_name":"battery discharge","score":0.6959999799728394},{"id":"https://openalex.org/keywords/uninterruptible-power-supply","display_name":"uninterruptible power supply","score":0.9200000166893005},{"id":"https://openalex.org/keywords/galvanic-isolation","display_name":"galvanic isolation","score":0.8579999804496765},{"id":"https://openalex.org/keywords/buck-mode","display_name":"buck mode","score":0.5989999771118164},{"id":"https://openalex.org/keywords/boost-mode","display_name":"boost mode","score":0.9580000042915344},{"id":"https://openalex.org/keywords/small-signal-analysis","display_name":"small-signal analysis","score":0.5950000286102295},{"id":"https://openalex.org/keywords/steady-state-analysis","display_name":"steady-state analysis","score":0.9049999713897705},{"id":"https://openalex.org/keywords/transient-response","display_name":"transient response","score":0.7300000190734863},{"id":"https://openalex.org/keywords/high-frequency-transformer","display_name":"high-frequency transformer","score":0.36399999260902405},{"id":"https://openalex.org/keywords/low-power-applications","display_name":"low power applications","score":0.7170000076293945}],"concepts":[{"id":"https://openalex.org/C55118286","wikidata":"https://www.wikidata.org/wiki/Q634739","display_name":"Forward converter","level":4,"score":0.5994729995727539},{"id":"https://openalex.org/C184720557","wikidata":"https://www.wikidata.org/wiki/Q7825049","display_name":"Topology (electrical circuits)","level":2,"score":0.5706860423088074},{"id":"https://openalex.org/C2778422915","wikidata":"https://www.wikidata.org/wiki/Q10302051","display_name":"Converters","level":3,"score":0.5636122822761536},{"id":"https://openalex.org/C70234604","wikidata":"https://www.wikidata.org/wiki/Q780813","display_name":"Galvanic isolation","level":4,"score":0.5389187335968018},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.530263364315033},{"id":"https://openalex.org/C150818752","wikidata":"https://www.wikidata.org/wiki/Q83804","display_name":"Buck converter","level":3,"score":0.5208121538162231},{"id":"https://openalex.org/C100329506","wikidata":"https://www.wikidata.org/wiki/Q336439","display_name":"\u0106uk converter","level":4,"score":0.5077008008956909},{"id":"https://openalex.org/C78336795","wikidata":"https://www.wikidata.org/wiki/Q760134","display_name":"Boost converter","level":3,"score":0.5074765086174011},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.49671751260757446},{"id":"https://openalex.org/C103303742","wikidata":"https://www.wikidata.org/wiki/Q1293595","display_name":"Flyback converter","level":4,"score":0.48284488916397095},{"id":"https://openalex.org/C184773241","wikidata":"https://www.wikidata.org/wiki/Q387400","display_name":"Mains electricity","level":3,"score":0.47935014963150024},{"id":"https://openalex.org/C66322947","wikidata":"https://www.wikidata.org/wiki/Q11658","display_name":"Transformer","level":3,"score":0.47412776947021484},{"id":"https://openalex.org/C42043438","wikidata":"https://www.wikidata.org/wiki/Q1671740","display_name":"Buck\u2013boost converter","level":4,"score":0.4724562466144562},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.46501070261001587},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.36398330330848694},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.3135090470314026}],"mesh":[],"locations_count":2,"locations":[{"id":"doi:10.1109/63.849029","doi":"https://doi.org/10.1109/63.849029","is_oa":false,"landing_page_url":"https://doi.org/10.1109/63.849029","pdf_url":null,"source":{"id":"https://openalex.org/S29875816","display_name":"IEEE Transactions on Power Electronics","issn_l":"0885-8993","issn":["0885-8993","1941-0107"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["cwts-core","dongbi-a","jufo-3","norway-2","poland-200","russia-white-list-1"],"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Power Electronics","raw_type":"journal-article"},{"id":"pmh:oai:CiteSeerX.psu:10.1.1.723.4232","doi":null,"is_oa":false,"landing_page_url":"http://citeseerx.ist.psu.edu/viewdoc/summary?doi=10.1.1.723.4232","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"http://profs.hut.ac.ir/%7Enaghizadeh/PE1%2093-2%20Term%20Papers/930342243.pdf","raw_type":"text"}],"best_oa_location":null,"sustainable_development_goals":[{"display_name":"Affordable and clean energy","score":0.9853000044822693,"id":"https://metadata.un.org/sdg/7"},{"display_name":"Industry, innovation and infrastructure","score":0.6773999929428101,"id":"https://metadata.un.org/sdg/9"}],"study_designs":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":15,"referenced_works":["https://openalex.org/W208655233","https://openalex.org/W1564169608","https://openalex.org/W2001918668","https://openalex.org/W2070957670","https://openalex.org/W2097442644","https://openalex.org/W2113100369","https://openalex.org/W2128962654","https://openalex.org/W2130327160","https://openalex.org/W2133835497","https://openalex.org/W2156827805","https://openalex.org/W2158114484","https://openalex.org/W2159230975","https://openalex.org/W2169564886","https://openalex.org/W2474809963","https://openalex.org/W3010286706"],"related_works":["https://openalex.org/W2134978199","https://openalex.org/W2358312402","https://openalex.org/W152176184","https://openalex.org/W2396159607","https://openalex.org/W2084796217","https://openalex.org/W2109981218","https://openalex.org/W4283207070","https://openalex.org/W1892294231","https://openalex.org/W1580395209","https://openalex.org/W2112102545"],"abstract_inverted_index":{"This":[0],"paper":[1],"presents":[2],"a":[3,19,25,33,49,101,126,158],"bidirectional":[4,39,87],"DC-DC":[5],"converter":[6,88,119,198],"for":[7,60,151],"use":[8,61],"in":[9,62,66,92,184],"low":[10],"power":[11,42,46,138],"applications.":[12],"The":[13,69,155,197],"proposed":[14,176],"topology":[15,55],"is":[16,57,121,161,182],"based":[17],"on":[18,21,28],"half-bridge":[20],"the":[22,29,44,74,80,86,93,98,110,115,118,129,132,140,166,175,185,192],"primary":[23],"and":[24,52,85,128,135,145,173,189,206],"current-fed":[26],"push-pull":[27],"secondary":[30],"side":[31],"of":[32,41,104,109,125,157,180,211],"high":[34],"frequency":[35],"isolation":[36],"transformer.":[37],"Achieving":[38],"flow":[40],"using":[43],"same":[45],"components":[47],"provides":[48,137,194],"simple,":[50],"efficient":[51],"galvanically":[53],"isolated":[54],"that":[56,124],"specially":[58],"attractive":[59],"battery":[63,99,130,186,193],"charge/discharge":[64],"circuits":[65],"DC":[67,70,111],"UPS.":[68],"mains":[71,112],"(provided":[72],"by":[73],"AC":[75,116],"mains),":[76,117],"when":[77,191],"presented,":[78],"powers":[79],"down":[81],"stream":[82],"load":[83,195,204],"converters":[84],"which":[89],"essentially":[90],"operates":[91],"buck":[94],"mode":[95,188,210],"to":[96,100,123,139,213],"charge":[97],"nominal":[102],"value":[103],"48":[105],"V.":[106],"On":[107],"failure":[108],"(derived":[113],"from":[114,165,208],"operation":[120,212],"comparable":[122],"boost":[127],"regulates":[131],"bus":[133],"voltage":[134],"thereby":[136],"downstream":[141],"converters.":[142],"Small":[143],"signal":[144],"steady":[146],"state":[147],"analyses":[148],"are":[149],"presented":[150],"this":[152],"specific":[153],"application.":[154],"design":[156],"laboratory":[159],"prototype":[160],"included.":[162],"Experimental":[163],"results":[164],"prototype,":[167],"under":[168,203],"different":[169],"operating":[170],"conditions,":[171],"validate":[172],"evaluate":[174],"topology.":[177],"An":[178],"efficiency":[179],"86.6%":[181],"achieved":[183],"charging":[187],"90%":[190],"power.":[196],"exhibits":[199],"good":[200],"transient":[201],"response":[202],"variations":[205],"switchover":[207],"one":[209],"another.":[214]},"cited_by_api_url":"https://api.openalex.org/works?filter=cites:W2162281450","counts_by_year":[{"year":2025,"cited_by_count":14},{"year":2024,"cited_by_count":7},{"year":2023,"cited_by_count":6},{"year":2022,"cited_by_count":10},{"year":2021,"cited_by_count":13},{"year":2020,"cited_by_count":16},{"year":2019,"cited_by_count":6},{"year":2018,"cited_by_count":19},{"year":2017,"cited_by_count":12},{"year":2016,"cited_by_count":16},{"year":2015,"cited_by_count":13},{"year":2014,"cited_by_count":15},{"year":2013,"cited_by_count":20},{"year":2012,"cited_by_count":16}],"updated_date":"2026-11-19T14:11:59.513116","created_date":"2016-06-24T00:00:00"}
