{"id":"https://openalex.org/W2159398686","doi":"https://doi.org/10.1093/rpd/ncn226","title":"Multichannel dosemeter and Al2O3:C optically stimulated luminescence fibre sensors for use in radiation therapy: evaluation with electron beams","display_name":"Multichannel dosemeter and Al2O3:C optically stimulated luminescence fibre sensors for use in radiation therapy: evaluation with electron beams","publication_year":2008,"publication_date":"2008-08-07","ids":{"openalex":"https://openalex.org/W2159398686","doi":"https://doi.org/10.1093/rpd/ncn226","mag":"2159398686","pmid":"https://pubmed.ncbi.nlm.nih.gov/18757901"},"language":"en","primary_location":{"id":"doi:10.1093/rpd/ncn226","doi":"https://doi.org/10.1093/rpd/ncn226","is_oa":true,"landing_page_url":"https://doi.org/10.1093/rpd/ncn226","pdf_url":"https://academic.oup.com/rpd/article-pdf/131/1/93/4521367/ncn226.pdf","source":{"id":"https://openalex.org/S201595455","display_name":"Radiation Protection Dosimetry","issn_l":"0144-8420","issn":["0144-8420","1742-3406"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["cwts-core","dongbi-c","doyens","jufo-1","ki-jl-1","medline","norway-1","poland-40","russia-white-list-3","vabb-shw"],"host_organization":"https://openalex.org/P4310311648","host_organization_name":"Oxford University Press","host_organization_lineage":["https://openalex.org/P4310311648","https://openalex.org/P4310311647"],"host_organization_lineage_names":["Oxford University Press","University of Oxford"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Radiation Protection Dosimetry","raw_type":"journal-article"},"volume":null,"type":"article","indexed_in":["crossref","pubmed"],"open_access":{"is_oa":true,"oa_status":"bronze","oa_url":"https://academic.oup.com/rpd/article-pdf/131/1/93/4521367/ncn226.pdf","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5090842367","display_name":"Sylvain Magne","orcid":"https://orcid.org/0000-0003-2508-4696","observed_orcids":["https://orcid.org/0000-0003-2508-4696"]},"institutions":[{"id":"https://openalex.org/I2738703131","display_name":"Commissariat \u00e0 l'\u00c9nergie Atomique et aux \u00c9nergies Alternatives","ror":"https://ror.org/00jjx8s55","country_code":"FR","type":"government","lineage":["https://openalex.org/I2738703131"]},{"id":"https://openalex.org/I4210085861","display_name":"Laboratoire d'Int\u00e9gration des Syst\u00e8mes et des Technologies","ror":"https://ror.org/000dbcc61","country_code":"FR","type":"government","lineage":["https://openalex.org/I2738703131","https://openalex.org/I277688954","https://openalex.org/I4210085861","https://openalex.org/I4210117989"]}],"countries":["FR"],"is_corresponding":true,"raw_author_name":"S. Magne","raw_affiliation_strings":["CEA, LIST, Laboratoire de Mesures Optiques, F-91191 Gif-sur-Yvette, France. sylvain.magne@cea.fr","CEA, LIST, Laboratoire de Mesures Optiques, F-91191 Gif-sur-Yvette, France"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"CEA, LIST, Laboratoire de Mesures Optiques, F-91191 Gif-sur-Yvette, France. sylvain.magne@cea.fr","institution_ids":["https://openalex.org/I2738703131","https://openalex.org/I4210085861"]},{"raw_affiliation_string":"CEA, LIST, Laboratoire de Mesures Optiques, F-91191 Gif-sur-Yvette, France","institution_ids":["https://openalex.org/I2738703131","https://openalex.org/I4210085861"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5004055594","display_name":"L. Auger","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I2738703131","display_name":"Commissariat \u00e0 l'\u00c9nergie Atomique et aux \u00c9nergies Alternatives","ror":"https://ror.org/00jjx8s55","country_code":"FR","type":"government","lineage":["https://openalex.org/I2738703131"]},{"id":"https://openalex.org/I4210085861","display_name":"Laboratoire d'Int\u00e9gration des Syst\u00e8mes et des Technologies","ror":"https://ror.org/000dbcc61","country_code":"FR","type":"government","lineage":["https://openalex.org/I2738703131","https://openalex.org/I277688954","https://openalex.org/I4210085861","https://openalex.org/I4210117989"]}],"countries":["FR"],"is_corresponding":false,"raw_author_name":"L. Auger","raw_affiliation_strings":["CEA, LIST, Laboratoire de Mesures Optiques, F-91191 Gif-sur-Yvette, France"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"CEA, LIST, Laboratoire de Mesures Optiques, F-91191 Gif-sur-Yvette, France","institution_ids":["https://openalex.org/I2738703131","https://openalex.org/I4210085861"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5111622846","display_name":"J.M. Bordy","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I2738703131","display_name":"Commissariat \u00e0 l'\u00c9nergie Atomique et aux \u00c9nergies Alternatives","ror":"https://ror.org/00jjx8s55","country_code":"FR","type":"government","lineage":["https://openalex.org/I2738703131"]},{"id":"https://openalex.org/I4210085861","display_name":"Laboratoire d'Int\u00e9gration des Syst\u00e8mes et des Technologies","ror":"https://ror.org/000dbcc61","country_code":"FR","type":"government","lineage":["https://openalex.org/I2738703131","https://openalex.org/I277688954","https://openalex.org/I4210085861","https://openalex.org/I4210117989"]},{"id":"https://openalex.org/I4210139115","display_name":"Laboratoire National Henri Becquerel","ror":"https://ror.org/03az79194","country_code":"FR","type":"facility","lineage":["https://openalex.org/I4210139115"]}],"countries":["FR"],"is_corresponding":false,"raw_author_name":"J. M. Bordy","raw_affiliation_strings":["CEA, LIST, Laboratoire National Henri Becquerel, F-91191 Gif-sur-Yvette, France"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"CEA, LIST, Laboratoire National Henri Becquerel, F-91191 Gif-sur-Yvette, France","institution_ids":["https://openalex.org/I2738703131","https://openalex.org/I4210085861","https://openalex.org/I4210139115"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5043554098","display_name":"L. de Carlan","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I2738703131","display_name":"Commissariat \u00e0 l'\u00c9nergie Atomique et aux \u00c9nergies Alternatives","ror":"https://ror.org/00jjx8s55","country_code":"FR","type":"government","lineage":["https://openalex.org/I2738703131"]},{"id":"https://openalex.org/I4210085861","display_name":"Laboratoire d'Int\u00e9gration des Syst\u00e8mes et des Technologies","ror":"https://ror.org/000dbcc61","country_code":"FR","type":"government","lineage":["https://openalex.org/I2738703131","https://openalex.org/I277688954","https://openalex.org/I4210085861","https://openalex.org/I4210117989"]},{"id":"https://openalex.org/I4210139115","display_name":"Laboratoire National Henri Becquerel","ror":"https://ror.org/03az79194","country_code":"FR","type":"facility","lineage":["https://openalex.org/I4210139115"]}],"countries":["FR"],"is_corresponding":false,"raw_author_name":"L. de Carlan","raw_affiliation_strings":["CEA, LIST, Laboratoire National Henri Becquerel, F-91191 Gif-sur-Yvette, France"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"CEA, LIST, Laboratoire National Henri Becquerel, F-91191 Gif-sur-Yvette, France","institution_ids":["https://openalex.org/I2738703131","https://openalex.org/I4210085861","https://openalex.org/I4210139115"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5024475662","display_name":"A. Isambert","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I2801843802","display_name":"Institut Gustave Roussy","ror":"https://ror.org/0321g0743","country_code":"FR","type":"facility","lineage":["https://openalex.org/I2801843802"]}],"countries":["FR"],"is_corresponding":false,"raw_author_name":"A. Isambert","raw_affiliation_strings":["Institut Gustave Roussy, Service de Physique, 39 rue Camille Desmoulins, F-94805 Villejuif, France"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Institut Gustave Roussy, Service de Physique, 39 rue Camille Desmoulins, F-94805 Villejuif, France","institution_ids":["https://openalex.org/I2801843802"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5079395537","display_name":"A. Bridier","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I2801843802","display_name":"Institut Gustave Roussy","ror":"https://ror.org/0321g0743","country_code":"FR","type":"facility","lineage":["https://openalex.org/I2801843802"]}],"countries":["FR"],"is_corresponding":false,"raw_author_name":"A. Bridier","raw_affiliation_strings":["Institut Gustave Roussy, Service de Physique, 39 rue Camille Desmoulins, F-94805 Villejuif, France"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Institut Gustave Roussy, Service de Physique, 39 rue Camille Desmoulins, F-94805 Villejuif, France","institution_ids":["https://openalex.org/I2801843802"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5054202854","display_name":"Pierre Ferdinand","orcid":"https://orcid.org/0000-0002-3825-5282","observed_orcids":["https://orcid.org/0000-0002-3825-5282"]},"institutions":[{"id":"https://openalex.org/I2738703131","display_name":"Commissariat \u00e0 l'\u00c9nergie Atomique et aux \u00c9nergies Alternatives","ror":"https://ror.org/00jjx8s55","country_code":"FR","type":"government","lineage":["https://openalex.org/I2738703131"]},{"id":"https://openalex.org/I4210085861","display_name":"Laboratoire d'Int\u00e9gration des Syst\u00e8mes et des Technologies","ror":"https://ror.org/000dbcc61","country_code":"FR","type":"government","lineage":["https://openalex.org/I2738703131","https://openalex.org/I277688954","https://openalex.org/I4210085861","https://openalex.org/I4210117989"]}],"countries":["FR"],"is_corresponding":false,"raw_author_name":"P. Ferdinand","raw_affiliation_strings":["CEA, LIST, Laboratoire de Mesures Optiques, F-91191 Gif-sur-Yvette, France"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"CEA, LIST, Laboratoire de Mesures Optiques, F-91191 Gif-sur-Yvette, France","institution_ids":["https://openalex.org/I2738703131","https://openalex.org/I4210085861"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5108551462","display_name":"Jean Barthe","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I2738703131","display_name":"Commissariat \u00e0 l'\u00c9nergie Atomique et aux \u00c9nergies Alternatives","ror":"https://ror.org/00jjx8s55","country_code":"FR","type":"government","lineage":["https://openalex.org/I2738703131"]},{"id":"https://openalex.org/I4210085861","display_name":"Laboratoire d'Int\u00e9gration des Syst\u00e8mes et des Technologies","ror":"https://ror.org/000dbcc61","country_code":"FR","type":"government","lineage":["https://openalex.org/I2738703131","https://openalex.org/I277688954","https://openalex.org/I4210085861","https://openalex.org/I4210117989"]}],"countries":["FR"],"is_corresponding":false,"raw_author_name":"J. Barthe","raw_affiliation_strings":["CEA, LIST, D\u00e9partement des Technologies du Capteur et du Signal, F-91191 Gif-sur-Yvette, France"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"CEA, LIST, D\u00e9partement des Technologies du Capteur et du Signal, F-91191 Gif-sur-Yvette, France","institution_ids":["https://openalex.org/I2738703131","https://openalex.org/I4210085861"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":4,"corresponding_author_ids":["https://openalex.org/A5090842367"],"corresponding_institution_ids":["https://openalex.org/I2738703131","https://openalex.org/I4210085861"],"apc_list":{"value":4533,"currency":"USD","value_usd":4533},"apc_paid":null,"fwci":3.5497,"has_fulltext":true,"cited_by_count":21,"citation_normalized_percentile":{"value":0.92383758,"is_in_top_1_percent":false,"is_in_top_10_percent":true},"cited_by_percentile_year":{"min":88,"max":96},"biblio":{"volume":"131","issue":"1","first_page":"93","last_page":"99"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10358","display_name":"Advanced Radiotherapy Techniques","score":0.9653000235557556,"subfield":{"id":"https://openalex.org/subfields/3108","display_name":"Radiation"},"field":{"id":"https://openalex.org/fields/31","display_name":"Physics and Astronomy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10358","display_name":"Advanced Radiotherapy Techniques","score":0.9653000235557556,"subfield":{"id":"https://openalex.org/subfields/3108","display_name":"Radiation"},"field":{"id":"https://openalex.org/fields/31","display_name":"Physics and Astronomy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11176","display_name":"Radiation Therapy and Dosimetry","score":0.00989999994635582,"subfield":{"id":"https://openalex.org/subfields/2740","display_name":"Pulmonary and Respiratory Medicine"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},{"id":"https://openalex.org/T11216","display_name":"Radiation Detection and Scintillator Technologies","score":0.00989999994635582,"subfield":{"id":"https://openalex.org/subfields/3108","display_name":"Radiation"},"field":{"id":"https://openalex.org/fields/31","display_name":"Physics and Astronomy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/optically-stimulated-luminescence","display_name":"optically stimulated luminescence","score":0.9269999861717224},{"id":"https://openalex.org/keywords/fiber-optic-sensors","display_name":"fiber optic sensors","score":0.7289999723434448},{"id":"https://openalex.org/keywords/in-vivo-dose-verification","display_name":"in vivo dose verification","score":0.7279999852180481},{"id":"https://openalex.org/keywords/radiotherapy","display_name":"radiotherapy","score":0.6639999747276306},{"id":"https://openalex.org/keywords/electron-beam","display_name":"electron beam","score":0.9459999799728394},{"id":"https://openalex.org/keywords/fading","display_name":"fading","score":0.47099998593330383},{"id":"https://openalex.org/keywords/temperature-dependence","display_name":"temperature dependence","score":0.9559999704360962},{"id":"https://openalex.org/keywords/sensor-calibration","display_name":"sensor calibration","score":0.7419999837875366},{"id":"https://openalex.org/keywords/depth-dose-measurement","display_name":"depth dose measurement","score":0.824999988079071},{"id":"https://openalex.org/keywords/multi-channel-readout","display_name":"multi-channel readout","score":0.6639999747276306}],"concepts":[{"id":"https://openalex.org/C125800877","wikidata":"https://www.wikidata.org/wiki/Q7098909","display_name":"Optically stimulated luminescence","level":3,"score":0.916994571685791},{"id":"https://openalex.org/C18231593","wikidata":"https://www.wikidata.org/wiki/Q186161","display_name":"Ionizing radiation","level":3,"score":0.6509218215942383},{"id":"https://openalex.org/C165838908","wikidata":"https://www.wikidata.org/wiki/Q736777","display_name":"Calibration","level":2,"score":0.6450074315071106},{"id":"https://openalex.org/C192562407","wikidata":"https://www.wikidata.org/wiki/Q228736","display_name":"Materials science","level":0,"score":0.555353045463562},{"id":"https://openalex.org/C148869448","wikidata":"https://www.wikidata.org/wiki/Q184240","display_name":"Luminescence","level":2,"score":0.5317316055297852},{"id":"https://openalex.org/C15359245","wikidata":"https://www.wikidata.org/wiki/Q1347805","display_name":"Thermalisation","level":2,"score":0.530704915523529},{"id":"https://openalex.org/C120665830","wikidata":"https://www.wikidata.org/wiki/Q14620","display_name":"Optics","level":1,"score":0.5138173699378967},{"id":"https://openalex.org/C153385146","wikidata":"https://www.wikidata.org/wiki/Q18335","display_name":"Radiation","level":2,"score":0.485895574092865},{"id":"https://openalex.org/C63007395","wikidata":"https://www.wikidata.org/wiki/Q2122891","display_name":"Dose profile","level":3,"score":0.48516780138015747},{"id":"https://openalex.org/C151337348","wikidata":"https://www.wikidata.org/wiki/Q215313","display_name":"Absorbed dose","level":3,"score":0.48246341943740845},{"id":"https://openalex.org/C154020017","wikidata":"https://www.wikidata.org/wiki/Q520171","display_name":"Repeatability","level":2,"score":0.48067745566368103},{"id":"https://openalex.org/C111337013","wikidata":"https://www.wikidata.org/wiki/Q2737837","display_name":"Irradiation","level":2,"score":0.4777787923812866},{"id":"https://openalex.org/C75088862","wikidata":"https://www.wikidata.org/wiki/Q2291081","display_name":"Dosimetry","level":2,"score":0.46608966588974},{"id":"https://openalex.org/C147120987","wikidata":"https://www.wikidata.org/wiki/Q2225","display_name":"Electron","level":2,"score":0.46396055817604065},{"id":"https://openalex.org/C151770136","wikidata":"https://www.wikidata.org/wiki/Q640610","display_name":"Ionization chamber","level":4,"score":0.4579126238822937},{"id":"https://openalex.org/C2989005","wikidata":"https://www.wikidata.org/wiki/Q214963","display_name":"Nuclear medicine","level":1,"score":0.34335485100746155},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.33663493394851685},{"id":"https://openalex.org/C49040817","wikidata":"https://www.wikidata.org/wiki/Q193091","display_name":"Optoelectronics","level":1,"score":0.2964091897010803},{"id":"https://openalex.org/C184779094","wikidata":"https://www.wikidata.org/wiki/Q26383","display_name":"Atomic physics","level":1,"score":0.2520166039466858},{"id":"https://openalex.org/C198291218","wikidata":"https://www.wikidata.org/wiki/Q190382","display_name":"Ionization","level":3,"score":0.23026800155639648},{"id":"https://openalex.org/C185544564","wikidata":"https://www.wikidata.org/wiki/Q81197","display_name":"Nuclear physics","level":1,"score":0.17464840412139893},{"id":"https://openalex.org/C185592680","wikidata":"https://www.wikidata.org/wiki/Q2329","display_name":"Chemistry","level":0,"score":0.16402298212051392},{"id":"https://openalex.org/C104293457","wikidata":"https://www.wikidata.org/wiki/Q28324852","display_name":"Imaging phantom","level":2,"score":0.1461595892906189},{"id":"https://openalex.org/C71924100","wikidata":"https://www.wikidata.org/wiki/Q11190","display_name":"Medicine","level":0,"score":0.1061505675315857},{"id":"https://openalex.org/C145148216","wikidata":"https://www.wikidata.org/wiki/Q36496","display_name":"Ion","level":2,"score":0.0798829197883606},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C43617362","wikidata":"https://www.wikidata.org/wiki/Q170050","display_name":"Chromatography","level":1,"score":0.0}],"mesh":[{"descriptor_ui":"D000465","descriptor_name":"Algorithms","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D000537","descriptor_name":"Aluminum Oxide","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D002138","descriptor_name":"Calibration","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D002244","descriptor_name":"Carbon","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D006801","descriptor_name":"Humans","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D009010","descriptor_name":"Monte Carlo Method","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D010315","descriptor_name":"Particle Accelerators","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D011878","descriptor_name":"Radiotherapy","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D011879","descriptor_name":"Radiotherapy Dosage","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D013696","descriptor_name":"Temperature","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D013819","descriptor_name":"Thermoluminescent Dosimetry","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":true},{"descriptor_ui":"D035501","descriptor_name":"Uncertainty","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false}],"locations_count":6,"locations":[{"id":"doi:10.1093/rpd/ncn226","doi":"https://doi.org/10.1093/rpd/ncn226","is_oa":true,"landing_page_url":"https://doi.org/10.1093/rpd/ncn226","pdf_url":"https://academic.oup.com/rpd/article-pdf/131/1/93/4521367/ncn226.pdf","source":{"id":"https://openalex.org/S201595455","display_name":"Radiation Protection Dosimetry","issn_l":"0144-8420","issn":["0144-8420","1742-3406"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["cwts-core","dongbi-c","doyens","jufo-1","ki-jl-1","medline","norway-1","poland-40","russia-white-list-3","vabb-shw"],"host_organization":"https://openalex.org/P4310311648","host_organization_name":"Oxford University Press","host_organization_lineage":["https://openalex.org/P4310311648","https://openalex.org/P4310311647"],"host_organization_lineage_names":["Oxford University Press","University of Oxford"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Radiation Protection Dosimetry","raw_type":"journal-article"},{"id":"pmid:18757901","doi":null,"is_oa":false,"landing_page_url":"https://pubmed.ncbi.nlm.nih.gov/18757901","pdf_url":null,"source":{"id":"https://openalex.org/S4306525036","display_name":"PubMed","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I1299303238","host_organization_name":"National Institutes of Health","host_organization_lineage":["https://openalex.org/I1299303238"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Radiation protection dosimetry","raw_type":"Journal Article"},{"id":"pmh:oai:HAL:cea-01840716v1","doi":null,"is_oa":false,"landing_page_url":"https://cea.hal.science/cea-01840716","pdf_url":null,"source":{"id":"https://openalex.org/S4306402512","display_name":"HAL","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I4405252976","host_organization_name":"Centre pour la Communication Scientifique Directe","host_organization_lineage":["https://openalex.org/I4405252976"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"Radiation Protection Dosimetry, 2008, 131 (1), pp.93 - 99. &#x27E8;10.1093/rpd/ncn226&#x27E9;","raw_type":"info:eu-repo/semantics/article"},{"id":"pmh:oai:HAL:cea-01840716v2","doi":null,"is_oa":true,"landing_page_url":"https://cea.hal.science/cea-01840716v2/document","pdf_url":null,"source":{"id":"https://openalex.org/S4306402512","display_name":"HAL","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I4405252976","host_organization_name":"Centre pour la Communication Scientifique Directe","host_organization_lineage":["https://openalex.org/I4405252976"],"host_organization_lineage_names":[],"type":"repository"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"Radiation Protection Dosimetry, 2008, 131 (1), pp.93 - 99. &#x27E8;10.1093/rpd/ncn226&#x27E9;","raw_type":"info:eu-repo/semantics/article"},{"id":"pmh:oai:open-archive.highwire.org:rpd:131/1/93","doi":null,"is_oa":false,"landing_page_url":"http://rpd.oxfordjournals.org/cgi/content/short/131/1/93","pdf_url":null,"source":{"id":"https://openalex.org/S4406923041","display_name":"HighWire Press Open Archive","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"","raw_type":"TEXT"},{"id":"pmh:oai:open-archive.highwire.org:rpd:ncn226v1","doi":null,"is_oa":false,"landing_page_url":"http://rpd.oxfordjournals.org/cgi/content/short/ncn226v1","pdf_url":null,"source":{"id":"https://openalex.org/S4406923041","display_name":"HighWire Press Open Archive","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"","raw_type":"TEXT"}],"best_oa_location":{"id":"doi:10.1093/rpd/ncn226","doi":"https://doi.org/10.1093/rpd/ncn226","is_oa":true,"landing_page_url":"https://doi.org/10.1093/rpd/ncn226","pdf_url":"https://academic.oup.com/rpd/article-pdf/131/1/93/4521367/ncn226.pdf","source":{"id":"https://openalex.org/S201595455","display_name":"Radiation Protection Dosimetry","issn_l":"0144-8420","issn":["0144-8420","1742-3406"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["cwts-core","dongbi-c","doyens","jufo-1","ki-jl-1","medline","norway-1","poland-40","russia-white-list-3","vabb-shw"],"host_organization":"https://openalex.org/P4310311648","host_organization_name":"Oxford University Press","host_organization_lineage":["https://openalex.org/P4310311648","https://openalex.org/P4310311647"],"host_organization_lineage_names":["Oxford University Press","University of Oxford"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Radiation Protection Dosimetry","raw_type":"journal-article"},"sustainable_development_goals":[],"study_designs":[],"awards":[{"id":"https://openalex.org/G6501747453","display_name":"CONCEPTION ET VALIDATION CLINIQUE DE CAPTEURS OSL \u00c0 FIBRES OPTIQUES POUR LA DOSIM\u00c9TRIE DES FAISCEAUX D\u2019\u00c9LECTRONS EN RADIOTH\u00c9RAPIE","funder_award_id":"ANR-06-TECS-0002","funder_id":"https://openalex.org/F4320320883","funder_display_name":"Agence Nationale de la Recherche"}],"funders":[{"id":"https://openalex.org/F4320320300","display_name":"European Commission","ror":"https://ror.org/00k4n6c32"},{"id":"https://openalex.org/F4320320883","display_name":"Agence Nationale de la Recherche","ror":"https://ror.org/00rbzpz17"}],"has_content":{"pdf":true,"grobid_xml":true},"content_urls":{"pdf":"https://content.openalex.org/works/W2159398686.pdf","grobid_xml":"https://content.openalex.org/works/W2159398686.grobid-xml"},"referenced_works_count":12,"referenced_works":["https://openalex.org/W1984875364","https://openalex.org/W1989397026","https://openalex.org/W2013721400","https://openalex.org/W2017078244","https://openalex.org/W2017135867","https://openalex.org/W2034517115","https://openalex.org/W2079568665","https://openalex.org/W2091450662","https://openalex.org/W2117198812","https://openalex.org/W2160755594","https://openalex.org/W2184405145","https://openalex.org/W2314229484"],"related_works":["https://openalex.org/W7048863622","https://openalex.org/W2138173596","https://openalex.org/W1992015839","https://openalex.org/W7125091613","https://openalex.org/W2017135867","https://openalex.org/W1998900110","https://openalex.org/W2109257986","https://openalex.org/W2050094241","https://openalex.org/W2314229484","https://openalex.org/W2008755418"],"abstract_inverted_index":{"This":[0],"article":[1],"proposes":[2],"an":[3,33,136],"innovative":[4],"multichannel":[5,114],"optically":[6],"stimulated":[7],"luminescence":[8],"(OSL)":[9],"dosemeter":[10],"for":[11],"on-line":[12],"in":[13,17,95,104,113,121],"vivo":[14],"dose":[15,144],"verification":[16],"radiation":[18,101],"therapy.":[19],"OSL":[20,51,60,107,134],"fibre":[21,26],"sensors":[22,108],"incorporating":[23],"small":[24],"Al(2)O(3):C":[25],"crystals":[27],"(TLD(500))":[28],"have":[29,86],"been":[30,87],"tested":[31],"with":[32,83,89],"X-ray":[34],"generator.":[35],"A":[36],"reproducible":[37],"readout":[38],"procedure":[39],"should":[40],"reduce":[41],"the":[42,65,122],"fading-induced":[43],"uncertainty":[44],"(":[45],"approximately":[46,56,70],"-":[47],"1%":[48],"per":[49],"decade).":[50],"readouts":[52],"are":[53],"temperature-dependent":[54],"[":[55],"0.3%":[57],"K(-1)":[58,72],"when":[59],"stimulation":[61],"is":[62],"performed":[63,88],"at":[64,98],"same":[66],"temperature":[67],"as":[68],"irradiation;":[69],"0.16%":[71],"after":[73],"thermalisation":[74],"(20":[75],"degrees":[76],"C)].":[77],"Sensor":[78],"calibration":[79,152],"and":[80,116,135],"depth-dose":[81],"measurements":[82],"electron":[84,119],"beams":[85],"a":[90,110,143,150],"Saturne":[91],"43":[92],"linear":[93],"accelerator":[94],"reference":[96,102],"conditions":[97],"CEA-LNHB":[99],"(ionising":[100],"laboratory":[103],"France).":[105],"Predosed":[106],"show":[109],"good":[111],"repeatability":[112],"operation":[115],"independence":[117],"versus":[118],"energy":[120],"range":[123],"(9,":[124],"18":[125],"MeV).":[126],"The":[127],"difference":[128],"between":[129],"absorbed":[130],"doses":[131],"measured":[132],"by":[133],"ionisation":[137],"chamber":[138],"were":[139],"within":[140],"+/-0.9%":[141],"(for":[142],"of":[145],"about":[146],"1":[147],"Gy)":[148],"despite":[149],"sublinear":[151],"curve.":[153]},"counts_by_year":[{"year":2026,"cited_by_count":1},{"year":2020,"cited_by_count":1},{"year":2018,"cited_by_count":2},{"year":2017,"cited_by_count":1},{"year":2016,"cited_by_count":1},{"year":2015,"cited_by_count":1},{"year":2014,"cited_by_count":1},{"year":2013,"cited_by_count":1},{"year":2012,"cited_by_count":1}],"updated_date":"2026-10-31T12:09:11.096373","created_date":"2016-06-24T00:00:00"}