{"id":"https://openalex.org/W2157444974","doi":"https://doi.org/10.1109/apex.2007.357505","title":"3D Power Delivery for Microprocessors and High-Performance ASICs","display_name":"3D Power Delivery for Microprocessors and High-Performance ASICs","alternate_titles":[],"publication_year":2007,"publication_date":"2007-02-01","ids":{"openalex":"https://openalex.org/W2157444974","doi":"https://doi.org/10.1109/apex.2007.357505","mag":"2157444974"},"language":"en","primary_location":{"id":"doi:10.1109/apex.2007.357505","doi":"https://doi.org/10.1109/apex.2007.357505","is_oa":false,"landing_page_url":"https://doi.org/10.1109/apex.2007.357505","pdf_url":null,"source":{"id":"https://openalex.org/S4210177957","display_name":"Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition","issn_l":"1048-2334","issn":["1048-2334","2470-6647"],"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":["jufo-1","norway-1"],"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"APEC 07 - Twenty-Second Annual IEEE Applied Power Electronics Conference and Exposition","raw_type":"proceedings-article"},"parent_works":[],"lineage":["https://openalex.org/W2157444974"],"child_works_count":0,"type":"conference-paper","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5071813318","display_name":"Jian Sun","orcid":"https://orcid.org/0000-0001-8820-5593","observed_orcids":["https://orcid.org/0000-0001-8820-5593"]},"institutions":[{"id":"https://openalex.org/I165799507","display_name":"Rensselaer Polytechnic Institute","ror":"https://ror.org/01rtyzb94","country_code":"US","type":"education","lineage":["https://openalex.org/I165799507"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Jian Sun","raw_affiliation_strings":["Department of Electrical, Computer, and Systems Engineering, Rensselaer Polytechnic Institute, Troy, NY, USA"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Electrical, Computer, and Systems Engineering, Rensselaer Polytechnic Institute, Troy, NY, USA","institution_ids":["https://openalex.org/I165799507"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5113691098","display_name":"Jian\u2010Qiang Lu","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I165799507","display_name":"Rensselaer Polytechnic Institute","ror":"https://ror.org/01rtyzb94","country_code":"US","type":"education","lineage":["https://openalex.org/I165799507"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Jian-Qiang Lu","raw_affiliation_strings":["Department of Electrical, Computer, and Systems Engineering, Rensselaer Polytechnic Institute, Troy, NY, USA"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Electrical, Computer, and Systems Engineering, Rensselaer Polytechnic Institute, Troy, NY, USA","institution_ids":["https://openalex.org/I165799507"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5072848012","display_name":"David M. Giuliano","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I165799507","display_name":"Rensselaer Polytechnic Institute","ror":"https://ror.org/01rtyzb94","country_code":"US","type":"education","lineage":["https://openalex.org/I165799507"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"David Giuliano","raw_affiliation_strings":["Department of Electrical, Computer, and Systems Engineering, Rensselaer Polytechnic Institute, Troy, NY, USA"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Electrical, Computer, and Systems Engineering, Rensselaer Polytechnic Institute, Troy, NY, USA","institution_ids":["https://openalex.org/I165799507"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5059828920","display_name":"T. Paul Chow","orcid":"https://orcid.org/0000-0002-1078-1707","observed_orcids":["https://orcid.org/0000-0002-1078-1707"]},"institutions":[{"id":"https://openalex.org/I165799507","display_name":"Rensselaer Polytechnic Institute","ror":"https://ror.org/01rtyzb94","country_code":"US","type":"education","lineage":["https://openalex.org/I165799507"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"T. Paul Chow","raw_affiliation_strings":["Department of Electrical, Computer, and Systems Engineering, Rensselaer Polytechnic Institute, Troy, NY, USA"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Electrical, Computer, and Systems Engineering, Rensselaer Polytechnic Institute, Troy, NY, USA","institution_ids":["https://openalex.org/I165799507"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5079222531","display_name":"Ronald J. Gutmann","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I165799507","display_name":"Rensselaer Polytechnic Institute","ror":"https://ror.org/01rtyzb94","country_code":"US","type":"education","lineage":["https://openalex.org/I165799507"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Ronald J. Gutmann","raw_affiliation_strings":["Department of Electrical, Computer, and Systems Engineering, Rensselaer Polytechnic Institute, Troy, NY, USA"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Electrical, Computer, and Systems Engineering, Rensselaer Polytechnic Institute, Troy, NY, USA","institution_ids":["https://openalex.org/I165799507"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":["https://openalex.org/I165799507"],"apc_list":null,"apc_paid":null,"fwci":11.5484,"has_fulltext":false,"cited_by_count":76,"citation_normalized_percentile":{"value":0.99287007,"is_in_top_1_percent":true,"is_in_top_10_percent":true},"cited_by_percentile_year":{"min":88,"max":99},"biblio":{"volume":null,"issue":null,"first_page":"127","last_page":"133"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10175","display_name":"Advanced DC-DC Converters","score":0.9961000084877014,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10175","display_name":"Advanced DC-DC Converters","score":0.9961000084877014,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11527","display_name":"3D IC and TSV technologies","score":0.0034000000450760126,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10323","display_name":"Analog and Mixed-Signal Circuit Design","score":9.999999747378752e-05,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/microprocessor-power-supply","display_name":"microprocessor power supply","score":0.7009999752044678},{"id":"https://openalex.org/keywords/interleaved-buck-converter","display_name":"interleaved buck converter","score":0.8330000042915344},{"id":"https://openalex.org/keywords/3d-integration","display_name":"3D integration","score":0.7609999775886536},{"id":"https://openalex.org/keywords/design-partitioning","display_name":"design partitioning","score":0.7160000205039978},{"id":"https://openalex.org/keywords/interconnect-parasitics","display_name":"interconnect parasitics","score":0.7620000243186951},{"id":"https://openalex.org/keywords/converter-efficiency","display_name":"converter efficiency","score":0.6650000214576721},{"id":"https://openalex.org/keywords/load-step-response","display_name":"load step response","score":0.6039999723434448},{"id":"https://openalex.org/keywords/filter-size-reduction","display_name":"filter size reduction","score":0.7099999785423279}],"concepts":[{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.5798721313476562},{"id":"https://openalex.org/C77390884","wikidata":"https://www.wikidata.org/wiki/Q217302","display_name":"Application-specific integrated circuit","level":2,"score":0.5268945693969727},{"id":"https://openalex.org/C123745756","wikidata":"https://www.wikidata.org/wiki/Q1665949","display_name":"Interconnection","level":2,"score":0.4995272159576416},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.49573835730552673},{"id":"https://openalex.org/C2776257435","wikidata":"https://www.wikidata.org/wiki/Q1576430","display_name":"Bandwidth (computing)","level":2,"score":0.46706897020339966},{"id":"https://openalex.org/C149635348","wikidata":"https://www.wikidata.org/wiki/Q193040","display_name":"Embedded system","level":1,"score":0.4575450122356415},{"id":"https://openalex.org/C45872418","wikidata":"https://www.wikidata.org/wiki/Q5318966","display_name":"Dynamic demand","level":3,"score":0.4426334500312805},{"id":"https://openalex.org/C118021083","wikidata":"https://www.wikidata.org/wiki/Q610398","display_name":"System on a chip","level":2,"score":0.430731862783432},{"id":"https://openalex.org/C150818752","wikidata":"https://www.wikidata.org/wiki/Q83804","display_name":"Buck converter","level":3,"score":0.41254866123199463},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.39996474981307983},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.29750940203666687},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.29476818442344666},{"id":"https://openalex.org/C76155785","wikidata":"https://www.wikidata.org/wiki/Q418","display_name":"Telecommunications","level":1,"score":0.12075778841972351},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.09437310695648193},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/apex.2007.357505","doi":"https://doi.org/10.1109/apex.2007.357505","is_oa":false,"landing_page_url":"https://doi.org/10.1109/apex.2007.357505","pdf_url":null,"source":{"id":"https://openalex.org/S4210177957","display_name":"Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition","issn_l":"1048-2334","issn":["1048-2334","2470-6647"],"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":["jufo-1","norway-1"],"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"APEC 07 - Twenty-Second Annual IEEE Applied Power Electronics Conference and Exposition","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/7","display_name":"Affordable and clean energy","score":0.75},{"id":"https://metadata.un.org/sdg/9","display_name":"Industry, innovation and infrastructure","score":0.5378999710083008}],"study_designs":[],"awards":[],"funders":[{"id":"https://openalex.org/F4320306076","display_name":"National Science Foundation","ror":"https://ror.org/021nxhr62"}],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":10,"referenced_works":["https://openalex.org/W153321780","https://openalex.org/W1545292401","https://openalex.org/W1943391756","https://openalex.org/W2025411433","https://openalex.org/W2100925189","https://openalex.org/W2112111321","https://openalex.org/W2144391331","https://openalex.org/W2341425605","https://openalex.org/W2399156338","https://openalex.org/W6632542457"],"related_works":["https://openalex.org/W2164887058","https://openalex.org/W3161584002","https://openalex.org/W7093378791","https://openalex.org/W4283710572","https://openalex.org/W4312576493","https://openalex.org/W2080299663","https://openalex.org/W7098470142","https://openalex.org/W4312413150","https://openalex.org/W2153775537","https://openalex.org/W2110392223"],"abstract_inverted_index":{"Conventional":[0],"power":[1,15,30,37,52],"delivery":[2,31],"methods":[3],"for":[4,115],"microprocessors":[5],"and":[6,65,99,127,140,178,189],"high-performance":[7],"ASICs":[8],"have":[9],"fundamental":[10],"limitations":[11],"in":[12,92,184],"meeting":[13],"the":[14,47,82,111,162,179,187],"requirements":[16,102],"of":[17,49,103,110,132,161,167,171,181],"future":[18,104],"IC":[19],"technologies":[20,57],"due":[21],"to":[22,46,84,96,154],"large":[23,169],"interconnect":[24],"parasitics.":[25],"A":[26,73],"new":[27],"three-dimensional":[28],"(3D)":[29],"approach":[32],"along":[33],"with":[34],"a":[35,43,88,93,129,168],"cellular":[36,94],"supply":[38],"architecture":[39,95],"is":[40,106,113,176],"proposed":[41],"as":[42,87,149,151],"possible":[44,59],"solution":[45],"problems":[48],"conventional":[50],"2D":[51],"delivery.":[53],"Different":[54],"3D":[55,67],"integration":[56,61],"or":[58],"power-processor":[60],"applications":[62],"are":[63,71,158,193],"reviewed,":[64],"important":[66],"design":[68,80,163],"partitioning":[69],"considerations":[70],"discussed.":[72],"fully":[74],"monolithic,":[75],"two-phase":[76],"interleaved":[77,182],"buck":[78],"converter":[79,112,174],"having":[81],"potential":[83],"be":[85],"used":[86],"basic":[89],"building":[90],"block":[91],"meet":[97],"steady-state":[98],"dynamic":[100,152],"regulation":[101],"processors":[105],"presented.":[107,159],"Each":[108],"cell":[109],"designed":[114],"500":[116],"mA":[117],"rated":[118],"output":[119,190],"current,":[120],"operates":[121],"at":[122],"200":[123],"MHz":[124],"switching":[125],"frequency,":[126],"achieves":[128],"control":[130],"bandwidth":[131],"about":[133],"10":[134],"MHz.":[135],"Design":[136],"trade-offs,":[137],"implementation":[138],"methods,":[139],"prototype":[141],"results":[142],"including":[143],"chip":[144],"area,":[145],"loss":[146],"breakdown,":[147],"efficiency,":[148],"well":[150],"responses":[153],"load":[155],"step":[156],"changes":[157],"Scaling-up":[160],"through":[164],"parallel":[165],"operation":[166,183],"number":[170],"such":[172],"standard":[173],"cells":[175],"discussed,":[177],"benefits":[180],"drastically":[185],"reducing":[186],"input":[188],"filter":[191],"size":[192],"quantified.":[194]},"cited_by_api_url":"https://api.openalex.org/works?filter=cites:W2157444974","counts_by_year":[{"year":2026,"cited_by_count":2},{"year":2025,"cited_by_count":1},{"year":2023,"cited_by_count":2},{"year":2022,"cited_by_count":2},{"year":2021,"cited_by_count":4},{"year":2019,"cited_by_count":1},{"year":2017,"cited_by_count":4},{"year":2016,"cited_by_count":4},{"year":2015,"cited_by_count":5},{"year":2014,"cited_by_count":4},{"year":2013,"cited_by_count":6},{"year":2012,"cited_by_count":10}],"updated_date":"2026-11-16T12:05:36.265796","created_date":"2016-06-24T00:00:00"}